Increased Stress Concentration in Prosthesis, Adhesive Cement, and Periodontal Tissue with Zirconia RBFDPs by the Reduced Alveolar Bone Height.

Erika Sukumoda1, Reina Nemoto1, Kosuke Nozaki1, Satoshi Omori1, Michiko Noda1, Miho Sato1, Mina Takita1, Hiroyuki Miura1.   

Abstract

PURPOSE: To investigate the risk of debonding of resin-bonded fixed dental prosthesis frameworks and the effects on the periodontal tissue in patients with reduced alveolar bone levels.
MATERIALS AND METHODS: The abutment teeth were the upper central incisor and the canine. Resin-bonded fixed dental prosthesis framework fabricated using zirconia was set to models with five different alveolar bone levels. A 200-N load (the maximum clenching force of the anterior teeth) was applied to the center of the pontic to analyze the internal stress on the framework, adhesive cement, and periodontal tissue using finite element analysis.
RESULTS: The mean maximum principal stress generated in the framework was 25.33 and 29.35 MPa in the models with the normal and the lowest alveolar bone level, respectively. Regarding shear stress on the adhesive cement, stress concentration was observed on the connector side in all models, and it increased on the cervical side of the central incisor as the alveolar bone level decreased. In addition, the mean maximum and minimum principal strains generated on the periodontal ligament of the central incisor and canine tended to increase as alveolar bone loss progressed. Furthermore, the mean maximum principal stress on the cortical bone was the greatest in the model with the most significant bone loss at 5.10 MPa.
CONCLUSIONS: This study suggested that the risk of debonding and periodontal tissue damage might be higher when resin-bonded fixed dental prosthesis frameworks were used in patients with reduced alveolar bone levels compared to those in a healthy state.
© 2020 by the American College of Prosthodontists.

Entities:  

Keywords:  3D-FEA; RBFDPs; YSZ; anterior teeth; periodontal tissue

Year:  2020        PMID: 33219705     DOI: 10.1111/jopr.13293

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  1 in total

Review 1.  Review of Biomechanical Studies and Finite Element Modeling of Sternal Closure Using Bio-Active Adhesives.

Authors:  Amatulraheem Al-Abassi; Marcello Papini; Mark Towler
Journal:  Bioengineering (Basel)       Date:  2022-05-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.