Kouki Tomida1,2, Hajime Nakae2.
Abstract
BACKGROUND: Muscular contracture may be caused by immobility-induced muscle atrophy and skeletal muscle hypoxia. Belt electrode skeletal muscle electrical stimulation (B-SES) is a new type of neuromuscular electrical stimulation that can simultaneously contract the lower limb muscle groups, in contrast to the conventional pad-type electrodes. B-SES can suppress muscular atrophy and relieve hypoxia of the skeletal muscle and is considered an appropriate strategy for preventing muscular contracture. However, the effect of B-SES on muscle flexibility has not been verified. This study aimed to compare the immediate effects of B-SES on skeletal muscle flexibility using different stimulation modes before the clinical study.Entities:
Mesh:
Year: 2020 PMID: 33217822 PMCID: PMC7676588 DOI: 10.1097/MD.0000000000023156
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.817
Within group comparison of the hamstring stiffness (Nm) before and after the intervention (n = 10).
| Disuse B-SES (20 Hz) | Metabolic B-SES (4 Hz) | Control group | |||
| Before | After | Before | After | Before | After |
| 28.4 ± 4.8 | 27.9 ± 5.2 | 29.0 ± 4.8 | 28.5 ± 5.0 | 27.9 ± 5.0 | 28.7 ± 5.0 |
All data are presented as mean ± standard deviation. A t-test was used for comparison.
B-SES = belt electrode skeletal muscle electrical stimulation.
Within-group comparison of the sit-and-reach distance (cm) before and after the intervention (n = 10).
| Disuse B-SES (20 Hz) | ∗Metabolic B-SES (4 Hz) | Control group | |||
| Before | After | Before | After | Before | After |
| 36.2 ± 8.5 | 39.0 ± 8.1 | 38.0 ± 8.5 | 41.4 ± 9.0 | 39.0 ± 9.3 | 38.1 ± 9.3 |
All data are presented as mean ± standard deviation. A paired t-test was used for comparison.
B-SES = belt electrode skeletal muscle electrical stimulation.
P value < .05.
Comparison of the change in hamstring stiffness (Nm) before and after the intervention between the groups (n = 10).
| Disuse B-SES (20 Hz) | Metabolic B-SES (4 Hz) | Control group | |
| –0.49 ± 2.0 | –0.52 ± 2.7 | 0.77 ± 2.2 | .1356 |
All data are presented as mean ± standard deviation. Repeated measures analysis of variance followed by the Bonferroni test was used for comparing the groups.
B-SES = belt electrode skeletal muscle electrical stimulation.
Comparison of the change in the sit-and-reach distance (cm) between the groups (n = 10).
| Disuse B-SES (20 Hz) | Metabolic B-SES (4 Hz) | Control group | ||
| 2.75 ± 4.3 | 3.45 ± 1.9 | −0.9 ± 2.3 | .0107 |
All data are presented as mean ± standard deviation. Repeated measures analysis of variance followed by the Bonferroni test was used for comparing the groups.
B-SES = belt electrode skeletal muscle electrical stimulation.
∗P value < .05.