Sir, The recent letter ‘The non-contact handheld cutaneous infra-red thermometer for fever screening during the COVID-19 global emergency’ expressed legitimate concerns about the accuracy of non-contact handheld infra-red thermometers for measuring temperature during the pandemic [1]. Non-contact handheld infra-red thermometers are indeed less accurate than tympanic thermometers and other infra-red thermal systems for the detection of fever [2]. In addition to the inadequacy of the equipment itself and the excessive distance between the thermometer and the skin [1], a worrying operator-dependent error exists. Although it is well known that handheld infra-red thermometers should be used to measure temperature at the temples or forehead, a large number of operators still use the forearm to save time and avoid close contact with the subject. The ‘real’ temperature of the human body is the core temperature, which is higher and more stable than the shell temperature [3,4]. The shell temperature, particularly skin temperature of the extremities, is vulnerable to the influence of environmental factors and thermoregulatory responses [4]. Therefore, measuring the temperature of forearm skin for the detection of fever is a colossal error. Tympanic infra-red thermometers have been shown to correlate with core temperature, and are more accurate than infra-red skin thermometers [5]. However, it is not practical to use tympanic thermometers in places with high human flow. The probe of the tympanic thermometer should be inserted as deep as possible into the auditory meatus to get close to the tympanic membrane. Moreover, in order to avoid cross-infection, it is necessary to change the cover of the probe each time. These operations will increase the time taken to perform each measurement, resulting in queuing and clustering. We strongly recommend the use of infra-red thermal imaging cameras at entrances to places with high pedestrian flow. Although thermal imagers only measure shell temperature, they have faster reaction speeds and a wider temperature acquisition area that avoids missing the potential hottest points of the body surface, such as the inner canthus of the eye [6]; as such, thermal imagers are more accurate than handheld infra-red thermometers [2,7]. If a person's temperature is higher than the set point, an alarm will alert the staff to measure the individual's temperature more accurately [8]. In addition, the recording function also monitors if an operator has missed a person with suspicious body temperature. During the COVID-19 global emergency, we propose a graded temperature measurement mode for the detection of fever: (1) infra-red thermal imaging cameras; (2) tympanic thermometers; and (3) sterilized thermometers for measuring axillary or rectal temperature. We recommend the use of infra-red thermal imaging cameras at the main entrances of hospitals, shopping malls, stations, airports, schools etc. for preliminary temperature measurements. Tympanic thermometers can be used in clinic rooms, aeroplanes, long-distance buses, hotels and classrooms to review temperature. Sterilized thermometers for axillary or rectal temperature are recommended in fever clinics, isolation wards, inpatient wards and for re-examination of cases of suspected fever.

Conflict of interest statement

None declared.

Funding sources

None.
  3 in total

1.  Evaluation of indoor hospital acclimatization of body temperature before COVID-19 fever screening.

Authors:  A Bassi; B M Henry; L Pighi; L Leone; G Lippi
Journal:  J Hosp Infect       Date:  2021-02-25       Impact factor: 3.926

2.  Variation of Forehead Temperature during Routine Working Shift in Hospital Laboratory Personnel: Implications for SARS-CoV-2 Screening.

Authors:  Giuseppe Lippi; Brandon Michael Henry; Ludovica Leone; Laura Pighi; Martina Montagnana
Journal:  J Lifestyle Med       Date:  2021-07-31

3.  Reliability of Non-Contact Infrared Thermometers for Fever Screening Under COVID-19.

Authors:  Fan Lai; Xin Li; Qi Wang; Yingjuan Luo; Xin Wang; Xiuhua Huang; Jiajia Zhang; Jieru Peng; Qin Wang; Li Fan; Wen Li; Junrong Huo; Tianjiao Liu; Yalan Li; Yonghong Lin; Xiao Yang
Journal:  Risk Manag Healthc Policy       Date:  2022-03-10