Zouheir Alsafra 1 , Georges Scholl 1 , Gauthier Eppe 1 . Show Affiliations »
Abstract
BACKGROUND: Furan and its alkyl substituted (2-methylfuran, 3-methylfuran, 2,3-dimethylfuran, 2,5-dimethylfuran) are found in a range between ppm to sub-ppb levels in many foodstuffs undergoing heat treatments like coffee, chicory, or even chocolate. OBJECTIVES: Two major objectives are presented. First, we aim at optimizing and validating a HS-SPME-GC-MS method for the quantification of five alkylfurans in chocolate. Second, we focus our study on measuring the quantitative impact of engraving technique on the formation of furan and its derivatives in chocolate, from the raw callets to processed end-products. METHOD: HS-SPME-GC-MS method operating in SIM mode and using isotope dilution technique with deuterated homologue internal standards was used to quantify alkylfurans in chocolate. RESULTS: Good repeatability (RSD% = 0.1-8%, in duplicate) and intermediate precision (RSD% = 1.7-7%, n = 6) were obtained for these five process contaminants at 10, 25, and 50 µg/kg. Trueness was varying between 81 and 109%. LoQ ranged from 0.48 to 2.50 µg/kg. Relative expanded measurement uncertainties ranged from 6 to 30%. Finally, tempering is responsible for a 24% increase in furan contamination, while the laser engraving technique results in an additional 31% increase in furan. A similar trend was also observed for 2-methylfuran and 3-methylfuran, whereas no significant increases were observed for 2,3-dimethylfuran and 2,5-dimethylfuran. CONCLUSIONS AND HIGHLIGHTS: A reliable and sensitive method of HS-SPME-GC-MS was reported for the first time for the analysis of furan and four alkylfurans in chocolate. This paper demonstrated that engraving using laser-based techniques can increase the levels of these compounds by up to 30%. © AOAC INTERNATIONAL 2020. All rights reserved. For permissions, please email: journals.permissions@oup.com.
BACKGROUND: Furan and its alkyl substituted (2-methylfuran, 3-methylfuran, 2,3-dimethylfuran, 2,5-dimethylfuran) are found in a range between ppm to sub-ppb levels in many foodstuffs undergoing heat treatments like coffee, chicory, or even chocolate. OBJECTIVES: Two major objectives are presented. First, we aim at optimizing and validating a HS-SPME-GC-MS method for the quantification of five alkylfurans in chocolate. Second, we focus our study on measuring the quantitative impact of engraving technique on the formation of furan and its derivatives in chocolate, from the raw callets to processed end-products. METHOD: HS-SPME-GC-MS method operating in SIM mode and using isotope dilution technique with deuterated homologue internal standards was used to quantify alkylfurans in chocolate. RESULTS: Good repeatability (RSD% = 0.1-8%, in duplicate) and intermediate precision (RSD% = 1.7-7%, n = 6) were obtained for these five process contaminants at 10, 25, and 50 µg/kg. Trueness was varying between 81 and 109%. LoQ ranged from 0.48 to 2.50 µg/kg. Relative expanded measurement uncertainties ranged from 6 to 30%. Finally, tempering is responsible for a 24% increase in furan contamination, while the laser engraving technique results in an additional 31% increase in furan. A similar trend was also observed for 2-methylfuran and 3-methylfuran, whereas no significant increases were observed for 2,3-dimethylfuran and 2,5-dimethylfuran. CONCLUSIONS AND HIGHLIGHTS: A reliable and sensitive method of HS-SPME-GC-MS was reported for the first time for the analysis of furan and four alkylfurans in chocolate. This paper demonstrated that engraving using laser-based techniques can increase the levels of these compounds by up to 30%. © AOAC INTERNATIONAL 2020. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Entities: Chemical
Mesh: See more »
Substances: See more »
Year: 2021
PMID: 33216911 DOI: 10.1093/jaoacint/qsaa102
Source DB: PubMed Journal: J AOAC Int ISSN: 1060-3271 Impact factor: 1.913