| Literature DB >> 33211764 |
Marta Gabryszewska1, Barbara Gworek1.
Abstract
Polychlorinated biphenyls (PCBs) have been withdrawn from the market due to their toxicity, bioaccumulation capacity, and persistence. PCBs have been observed to potentially form in combustion processes under appropriate conditions and in the presence of precursors containing chlorine. The study covered a municipal waste incineration plant and an industrial waste incineration plant. The objective of the study was to assess the effect of these objects on PCB accumulation in soil and plants taking into account the distance from the emission object and wind direction. Soil samples were collected from layers: 0-5, 5-10, 10-20, and 20-30 cm. Test plants were collected from the same areas as the soil samples. The highest accumulation of PCBs was found in plants with large leaf area. Around the municipal waste incineration plant, these were Tanacetum vulgare leaves (12.45 ng/g), and around the industrial waste incineration plant-grasses (4.3 ng/g). In the case of soils, the accumulation of PCBs for both kind waste incinerators was similar, reaching approximately 3 ng/g. As the distance from the municipal waste incinerator and industrial waste incinerator increased, the accumulation of PCBs in the soil decreased. For municipal waste incinerator, no effect of wind direction on PCB accumulation in the soil was observed. In the majority of cases, the accumulation of PCBs in soils taken from the leeward side of the industrial waste incinerator was higher than that in soils from the windward side. In soils around the municipal waste incinerator, PCB compounds moved deep into the soil and reached the highest accumulation in the soil layer of 10-20 cm or 20-30 cm. In soils around the industrial waste incinerator, the highest accumulation of PCBs occurred in the soil layer of 0-5 cm.Entities:
Mesh:
Substances:
Year: 2020 PMID: 33211764 PMCID: PMC7676720 DOI: 10.1371/journal.pone.0242698
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Map of research areas around waste incinerators.
List of the plants collected for testing around municipal and industrial waste incinerators.
| Plot No. | Plants from the municipal waste incinerator area (abbreviation) | Plants from industrial waste incinerator area (abbreviation) |
|---|---|---|
The average distances of test areas from chimneys of municipal and industrial waste incinerators.
| Plot No. | The average distance from the test area to the incinerator stack (m) | |
|---|---|---|
| Municipal waste incinerator | Industrial waste incinerator | |
| 103 | 170 | |
| 207 | 238 | |
| 460 | 148 | |
| 500 | 670 | |
| 440 | 568 | |
Validation parameters.
| PCBs congener | 28 | 52 | 44 | 99 | 101 | 95 | 110 | 118 | 153 | 105 | 138 | 180 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 30.153 | 31.427 | 32.185 | 33.748 | 34.590 | 34.739 | 35.938 | 37.022 | 37.802 | 38.220 | 39.208 | 41.905 | |
| 0.999 | 0.998 | 0.996 | 0.995 | 0.995 | 0.995 | 0.995 | 0.998 | 0.995 | 0.995 | 0.997 | 0.997 | |
| 0.02 | 0.04 | 0.03 | 0.03 | 0.04 | 0.03 | 0.03 | 0.04 | 0.02 | 0.04 | 0.03 | 0.07 | |
| 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.01 | 0.02 | |
| 13 | 7 | 10 | 8 | 9 | 20 | 30 | 23 | 15 | 22 | 10 | 24 | |
| 79 | 88 | 64 | 77 | 75 | 95 | 82 | 111 | 120 | 105 | 103 | 125 | |
| 15 | 19 | 13 | 17 | 19 | 11 | 15 | 18 | 16 | 13 | 13 | 14 | |
| 95 | 56 | 53 | 58 | 51 | 54 | 59 | 51 | 50 | 54 | 53 | 54 | |
| 10 | 9 | 10 | 17 | 10 | 10 | 18 | 18 | |||||
| 81 | 81 | 75 | 72 | 80 | 88 | 122 | 98 | |||||
| 6 | 9 | 16 | 12 | 10 | 11 | 13 | 9 | 10 | 13 | 11 | 15 | |
| 120 | 112 | 114 | 116 | 123 | 125 | 116 | 99 | 95 | 100 | 104 | 97 |
PCBs congener content in the soil around municipal waste incinerator (ng/g).
| Plot No./depth (cm) | PCBs congeners | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 28 | 52 | 101 | 118 | 153 | 138 | 180 | 44 | 105 | 110 | 95 + 99 | |
| < 0.003 | 0.167 | 0.012 | 0.043 | < 0.003 | < 0.003 | 0.061 | 0.232 | 0.200 | 1.982 | < 0.003 | |
| 0.057 | 0.203 | < 0.003 | 0.019 | < 0.003 | 0.005 | 0.058 | 0.137 | 0.090 | 0.756 | < 0.003 | |
| 0.087 | 0.311 | < 0.003 | 0.031 | < 0.003 | < 0.003 | 0.089 | 0.206 | 0.086 | 0.727 | 0.034 | |
| 0.006 | 0.381 | 0.021 | 0.065 | < 0.003 | 0.021 | 0.336 | 0.265 | 0.352 | 1.489 | 0.080 | |
| 0.028 | 0.182 | 0.080 | 0.168 | 0.179 | < 0.003 | < 0.003 | 0.281 | 0.086 | 0.193 | 0.146 | |
| 0.018 | 0.184 | 0.087 | 0.101 | 0.163 | < 0.003 | < 0.003 | 0.473 | 0.091 | 0.300 | 0.112 | |
| 0.029 | 0.222 | 0.144 | 0.107 | 0.164 | < 0.003 | < 0.003 | 0.299 | 0.131 | 0.328 | 0.189 | |
| 0.010 | 0.405 | 0.135 | 0.065 | 0.078 | < 0.003 | < 0.003 | 0.644 | 0.053 | 0.266 | 0.071 | |
| 0.010 | 0.037 | 0.054 | 0.056 | 0.060 | < 0.003 | 0.041 | < 0.003 | 0.037 | 0.186 | 0.042 | |
| 0.012 | 0.011 | < 0.003 | 0.020 | < 0.003 | < 0.003 | 0.054 | < 0.003 | 0.022 | 0.018 | < 0.003 | |
| 0.012 | 0.040 | < 0.003 | < 0.003 | 0.006 | < 0.003 | < 0.003 | < 0.003 | 0.022 | < 0.003 | 0.026 | |
| 0.013 | < 0.003 | < 0.003 | < 0.003 | < 0.003 | < 0.003 | 0.021 | < 0.003 | < 0.003 | < 0.003 | 0.047 | |
| 0.007 | 0.044 | < 0.003 | < 0.003 | 0.041 | < 0.003 | 0.039 | < 0.003 | < 0.003 | 0.040 | 0.014 | |
| 0.013 | 0.031 | < 0.003 | 0.015 | 0.101 | < 0.003 | 0.033 | < 0.003 | < 0.003 | 0.053 | < 0.003 | |
| 0.019 | 0.042 | < 0.003 | 0.072 | 0.078 | < 0.003 | 0.021 | < 0.003 | < 0.003 | 0.050 | < 0.003 | |
| 0.012 | 0.090 | < 0.003 | 0.048 | 0.067 | < 0.003 | 0.015 | 0.015 | 0.017 | 0.042 | < 0.003 | |
Fig 2Dependence of PCBs accumulation in the topsoil layer on the distance from waste incinerator plants.
PCBs congener content in soil layers around industrial waste incinerators (ng/g).
| Plot No./depth (cm) | PCBs congeners | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 28 | 52 | 101 | 118 | 153 | 138 | 180 | 44 | 105 | 110 | 95 + 99 | |
| 0.037 | 0.139 | 0.034 | < 0.003 | 1.755 | < 0.003 | 0.065 | 0.114 | 0.059 | 0.089 | 0.061 | |
| 0.005 | 0.033 | 0.027 | 0.040 | < 0.003 | < 0.003 | 0.010 | 0.019 | < 0.003 | 0.015 | < 0.003 | |
| 0.010 | 0.068 | < 0.003 | 0.029 | < 0.003 | < 0.003 | < 0.003 | < 0.003 | < 0.003 | 0.015 | 0.016 | |
| 0.011 | 0.049 | < 0.003 | < 0.003 | < 0.003 | 0.061 | 0.021 | < 0.003 | < 0.003 | 0.016 | 0.006 | |
| 0.013 | 0.236 | 0.035 | 0.081 | 1.823 | 0.048 | 0.086 | 0.065 | < 0.003 | 0.160 | 0.041 | |
| 0.048 | 0.117 | 0.032 | 0.014 | < 0.003 | 0.044 | 0.061 | 0.015 | < 0.003 | 0.171 | 0.019 | |
| < 0.003 | < 0.003 | < 0.003 | < 0.003 | < 0.003 | 0.040 | < 0.003 | 0.039 | < 0.003 | 0.194 | 0.006 | |
| 0.014 | < 0.003 | 0.022 | < 0.003 | < 0.003 | 0.017 | < 0.003 | 0.017 | < 0.003 | 0.067 | 0.014 | |
| 0.011 | 0.070 | 0.029 | 0.054 | < 0.003 | 0.040 | 0.174 | 0.027 | 0.079 | 0.185 | 0.034 | |
| 0.012 | 0.078 | 0.019 | < 0.003 | < 0.003 | 0.079 | 0.073 | 0.015 | 0.072 | 0.342 | 0.031 | |
| 0.005 | 0.058 | < 0.003 | 0.011 | < 0.003 | 0.055 | 0.039 | 0.006 | 0.071 | 0.132 | 0.035 | |
| 0.004 | 0.016 | < 0.003 | < 0.003 | < 0.003 | 0.049 | < 0.003 | < 0.003 | < 0.003 | 0.013 | 0.013 | |
| 0.015 | 0.169 | < 0.003 | 0.043 | < 0.003 | 0.099 | 0.038 | 0.057 | 0.042 | 0.015 | < 0.003 | |
| 0.030 | 0.863 | 0.020 | 0.055 | < 0.003 | 0.025 | 0.031 | 0.076 | < 0.003 | 0.101 | < 0.003 | |
Fig 3Content of PCBs congeners in plants collected around municipal waste incineration plants; Tv l—Tanacetum vulgare leaves, Tv s—Tanacetum vulgare stalk, Sc l—Solidago canadensis leaves, Sc s—Solidago canadensis stalk.
Fig 4Contents of PCBs congeners in plants collected around industrial waste incineration plants, Pi1—Pinus L. one-year-old needles Pi2—Pinus L. two-year-old needles.
Values of BAC for plants from the municipal waste incinerator.
| Plot No./plant | PCBs congeners | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 28 | 52 | 101 | 118 | 153 | 138 | 180 | 44 | 110 | 95 + 99 | |
| 41.92 | 20.60 | 0.83 | - | 0.98 | 2.37 | 1.24 | 26.10 | 1.51 | 12.06 | |
| 4.63 | 2.38 | - | - | - | 0.57 | - | 5.66 | - | 2.02 | |
| 68.98 | 33.18 | - | - | 1.52 | 2.64 | - | 55.70 | 5.89 | 20.04 | |
| 5.16 | - | - | - | - | - | - | - | - | - | |
| 16.17 | - | - | - | - | 1.39 | - | - | - | - | |
| 45.62 | 14.90 | 4.35 | 4.42 | 3.84 | 1.78 | - | 22.81 | 11.90 | 14.76 | |
| 63.65 | 21.25 | - | - | 1.01 | - | 1.28 | 25.93 | 1.56 | 9.96 | |
| 1.74 | 4.70 | - | 25.98 | - | - | - | - | - | - | |
Where [–] means not calculated due to PCBs content below the detection limit.
Values of BAC for plants from the industrial waste incinerator.
| Plot No./plant | PCBs congener | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 28 | 52 | 101 | 118 | 153 | 138 | 180 | 44 | 105 | 110 | 95 + 99 | |
| 8.49 | 30.48 | 26.67 | 19.07 | 74.29 | 39.43 | 13.34 | 19.01 | 16.84 | 35.17 | 25.89 | |
| 11.86 | 24.85 | - | 14.03 | 14.64 | - | 6.21 | 9.66 | - | 90.75 | 12.06 | |
| 8.41 | 13.22 | - | 2.99 | 3.90 | - | 1.10 | - | - | 28.17 | 10.69 | |
Where [–] means not calculated due to PCBs content below the detection limit.