Comparison of the Conox (qCON) and Sedline (PSI) depth of anaesthesia indices to predict the hypnotic effect during desflurane general anaesthesia with ketamine.

Catherine Christenson1, Pablo Martinez-Vazquez2,3, Max Breidenstein1, Borzoo Farhang1, Jackson Mathews1, Umberto Melia4, Erik Weber Jensen4,5, Donald Mathews1.   

Abstract

Comparison of two depth of anesthesia indices, qCON (Conox) and PSI (Sedline), during desflurane sedation and their sensitivity to random ketamine boluses in patients undergoing routine surgery. The performance of desflurane and ketamine on both indices was analyzed for 11 patients, and the ketamine sensitivity was compared with another group of 11 patients under sevoflurane and propofol.The MOAA/S was used to determine sedation level and pain. Different boluses of ketamine ranging from 10 to 30 mg where randomly administered in both groups and the effect on the indexes were measured after 4 min.The indices were recorded during the whole surgery, and their correlations with the desflurane concentration and the discrimination between awake and anesthetized states were evaluated with the prediction probability statistic (Pk). The Pk values, mean (se), discriminating between awake and anesthetized states were 0.974(0.016) for the qCON and 0.962(0.0123) for the PSI, while the 1-Pk statistic for the qCON and the PSI with respect to the desflurane concentration were 0.927(0.016) and 0.918(0.018), respectively, with no statistically significant differences.The agreement between both depth of hypnosis parameters was assessed under the Bland-Altman plot and the Spearman correlation, rs = 0.57(p < 0.001).During the sevoflurane-propofol anesthesia, which served as a control group, both indices experienced a similar behavior with a no significant change of their median values after ketamine. However, during desflurane anesthesia the qCON index did not change significantly after ketamine administration, qCON (before = 33 (4), after = 30 (17); Wilcoxon, p = 0.89), while the PSI experienced a significant increase, PSI (before = 31(6), after = 39(16) Wilcoxon, p = 0.013).This study shows that qCON and PSI have similar performance under desflurane with good discrimination between the awake and anesthetized states. While both indices exhibited similar behavior under ketamine boluses under a sevoflurane-propofol anesthesia, the qCON index had a better performance under ketamine during desflurane anesthesia.
© 2020. Springer Nature B.V.

Entities:  

Keywords:  Anesthesia; Depth; EEG; Ketamine; Propofol; Sevoflurane

Mesh:

Substances:

Year:  2020        PMID: 33211251     DOI: 10.1007/s10877-020-00619-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   1.977


  4 in total

1.  Effect of ketamine on bispectral index during propofol--fentanyl anesthesia: a randomized controlled study.

Authors:  Saikat Sengupta; Simantika Ghosh; Amitava Rudra; Palash Kumar; Gaurab Maitra; Tanmoy Das
Journal:  Middle East J Anaesthesiol       Date:  2011-10

2.  Sevoflurane potentiates and blocks GABA-induced currents through recombinant alpha1beta2gamma2 GABAA receptors: implications for an enhanced GABAergic transmission.

Authors:  G Hapfelmeier; H Schneck; E Kochs
Journal:  Eur J Anaesthesiol       Date:  2001-06       Impact factor: 4.330

3.  Bispectral index monitoring prevent awareness during total intravenous anesthesia: a prospective, randomized, double-blinded, multi-center controlled trial.

Authors:  Chen Zhang; Liang Xu; Ya-Qun Ma; Yan-Xia Sun; Yan-Hong Li; Liang Zhang; Chun-Sheng Feng; Bing Luo; Zhen-Long Zhao; Jian-Rong Guo; Yao-Jun Jin; Gang Wu; Wei Yuan; Zhi-Guo Yuan; Yun Yue
Journal:  Chin Med J (Engl)       Date:  2011-11       Impact factor: 2.628

4.  Frontal EEG Temporal and Spectral Dynamics Similarity Analysis between Propofol and Desflurane Induced Anesthesia Using Hilbert-Huang Transform.

Authors:  Quan Liu; Li Ma; Shou-Zen Fan; Maysam F Abbod; Qingsong Ai; Kun Chen; Jiann-Shing Shieh
Journal:  Biomed Res Int       Date:  2018-07-15       Impact factor: 3.411

  4 in total
  2 in total

1.  Electroencephalogram-Based Evaluation of Impaired Sedation in Patients with Moderate to Severe COVID-19 ARDS.

Authors:  Armin Niklas Flinspach; Sebastian Zinn; Kai Zacharowski; Ümniye Balaban; Eva Herrmann; Elisabeth Hannah Adam
Journal:  J Clin Med       Date:  2022-06-17       Impact factor: 4.964

2.  Comparison of Quantium Consciousness Index and Richmond Agitation Sedation Scale in Mechanically Ventilated Critically Ill Patients: An Observational Study.

Authors:  Makam S Harsha; Pradeep K Bhatia; Ankur Sharma; Priyanka Sethi
Journal:  Indian J Crit Care Med       Date:  2022
  2 in total