Literature DB >> 33211150

Non-invasive assessment of cirrhosis using multiphasic dual-energy CT iodine maps: correlation with model for end-stage liver disease score.

Domenico Mastrodicasa1, Martin J Willemink1, Celina Duran2, Andrea Delli Pizzi3, Virginia Hinostroza1, Lior Molvin1, Mohamed Khalaf1, R Brooke Jeffrey1, Bhavik N Patel4.   

Abstract

PURPOSE: To determine whether multiphasic dual-energy (DE) CT iodine quantitation correlates with the severity of chronic liver disease.
METHODS: We retrospectively included 40 cirrhotic and 28 non-cirrhotic patients who underwent a multiphasic liver protocol DECT. All three phases (arterial, portal venous (PVP), and equilibrium) were performed in DE mode. Iodine (I) values (mg I/ml) were obtained by placing regions of interest in the liver, aorta, common hepatic artery, and portal vein (PV). Iodine slopes (λ) were calculated as follows: (Iequilibrium-Iarterial)/time and (Iequilibrium-IPVP)/time. Spearman correlations between λ and MELD scores were evaluated, and the area under the curve of the receiver operating characteristic (AUROC) was calculated to distinguish cirrhotic and non-cirrhotic patients.
RESULTS: Cirrhotic and non-cirrhotic patients had significantly different λequilibrium-arterial [IQR] for the caudate (λ = 2.08 [1.39-2.98] vs 1.46 [0.76-1.93], P = 0.007), left (λ = 2.05 [1.50-2.76] vs 1.51 [0.59-1.90], P = 0.002) and right lobes (λ = 1.72 [1.12-2.50] vs 1.13 [0.41-0.43], P = 0.003) and for the PV (λ = 3.15 [2.20-5.00] vs 2.29 [0.85-2.71], P = 0.001). λequilibrium-PVP were significantly different for the right (λ = 0.11 [- 0.45-1.03] vs - 0.44 [- 0.83-0.12], P = 0.045) and left lobe (λ = 0.30 [- 0.25-0.98] vs - 0.10 [- 0.35-0.24], P = 0.001). Significant positive correlations were found between MELD scores and λequilibrium-arterial for the caudate lobe (ρ = 0.34, P = 0.004) and λequilibrium-PVP for the caudate (ρ = 0.26, P = 0.028) and right lobe (ρ = 0.33, P = 0.007). AUROC in distinguishing cirrhotic and non-cirrhotic patients were 0.72 (P = 0.002), 0.71 (P = 0.003), and 0.75 (P = 0.001) using λequilibrium-arterial for the left lobe, right lobe, and PV, respectively. The λequilibrium-PVP AUROC of the right lobe was 0.73 (P = 0.001).
CONCLUSION: Multiphasic DECT iodine quantitation over time is significantly different between cirrhotic and non-cirrhotic patients, correlates with the MELD score, and it could potentially serve as a non-invasive measure of cirrhosis and disease severity with acceptable diagnostic accuracy.

Entities:  

Keywords:  Chronic liver disease; Dual-energy CT; Iodine concentration; Liver cirrhosis; Material decomposition

Mesh:

Substances:

Year:  2020        PMID: 33211150      PMCID: PMC9282666          DOI: 10.1007/s00261-020-02857-0

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  50 in total

1.  Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition.

Authors:  Xin Liu; Lifeng Yu; Andrew N Primak; Cynthia H McCollough
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

Review 2.  Noninvasive biomarkers in NAFLD and NASH - current progress and future promise.

Authors:  Vincent Wai-Sun Wong; Leon A Adams; Victor de Lédinghen; Grace Lai-Hung Wong; Silvia Sookoian
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2018-08       Impact factor: 46.802

Review 3.  Burden of liver diseases in the world.

Authors:  Sumeet K Asrani; Harshad Devarbhavi; John Eaton; Patrick S Kamath
Journal:  J Hepatol       Date:  2018-09-26       Impact factor: 25.083

4.  Stratification of patients with liver fibrosis using dual-energy CT.

Authors:  Peter Lamb; Dushyant V Sahani; Jorge M Fuentes-Orrego; Manuel Patino; Asish Ghosh; Paulo R S Mendonça
Journal:  IEEE Trans Med Imaging       Date:  2014-08-28       Impact factor: 10.048

5.  Interdependencies of acquisition, detection, and reconstruction techniques on the accuracy of iodine quantification in varying patient sizes employing dual-energy CT.

Authors:  Daniele Marin; Jose J Pratts-Emanuelli; Achille Mileto; Daniela B Husarik; Mustafa R Bashir; Rendon C Nelson; Daniel T Boll
Journal:  Eur Radiol       Date:  2014-10-03       Impact factor: 5.315

6.  Multiparametric CT for Noninvasive Staging of Hepatitis C Virus-Related Liver Fibrosis: Correlation With the Histopathologic Fibrosis Score.

Authors:  Perry J Pickhardt; Peter M Graffy; Adnan Said; Daniel Jones; Brandon Welsh; Ryan Zea; Meghan G Lubner
Journal:  AJR Am J Roentgenol       Date:  2019-01-15       Impact factor: 3.959

7.  Feasibility study for assessing liver fibrosis in paediatric and adolescent patients using real-time shear wave elastography.

Authors:  Manish Dhyani; Michael S Gee; Joseph Misdraji; Esther Jacobowitz Israel; Uzma Shah; Anthony E Samir
Journal:  J Med Imaging Radiat Oncol       Date:  2015-10-27       Impact factor: 1.735

8.  Dual-Energy CT Material Density Iodine Quantification for Distinguishing Vascular From Nonvascular Renal Lesions: Normalization Reduces Intermanufacturer Threshold Variability.

Authors:  Bhavik N Patel; Federica Vernuccio; Mathias Meyer; Benjamin Godwin; Michael Rosenberg; Nicholas Rudnick; Scott Harring; Rendon Nelson; Juan Carlos Ramirez-Giraldo; Alfredo Farjat; Daniele Marin
Journal:  AJR Am J Roentgenol       Date:  2019-02       Impact factor: 3.959

9.  Clinical application of ultrasonography-guided percutaneous liver biopsy and its safety over 18 years.

Authors:  Young Chang; Jun Il Kim; Bora Lee; Sang Gyune Kim; Min Jung Jung; Young Seok Kim; Soung Won Jeong; Jae Young Jang; Jeong-Ju Yoo
Journal:  Clin Mol Hepatol       Date:  2020-05-25

10.  Equilibrium contrast-enhanced CT imaging to evaluate hepatic fibrosis: initial validation by comparison with histopathologic sampling.

Authors:  Steve Bandula; Shonit Punwani; William M Rosenberg; Rajiv Jalan; Andrew R Hall; Amar Dhillon; James C Moon; Stuart A Taylor
Journal:  Radiology       Date:  2014-12-08       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.