Oxytocin selectively reduces blood flow in uterine fibroids without an effect on myometrial blood flow: a dynamic contrast enhanced MRI evaluation.

Saara Otonkoski1,2, Teija Sainio3,4, Gaber Komar2,3, Visa Suomi2,3, Jani Saunavaara3,4, Roberto Blanco Sequeiros2,3, Antti Perheentupa1,2, Kirsi Joronen1,2.   

Abstract

INTRODUCTION: Uterine fibroids are the most common benign neoplasms in women. The administration of intravenous oxytocin is known to increase the efficacy of a non-invasive thermal ablation method (MR-HIFU) for treating fibroids. However, it is not known whether this phenomenon is caused by the effect of the oxytocin on the myometrium or the fibroid itself. The objective of this study was to evaluate the influence of oxytocin on the blood flow of fibroids, myometrium and skeletal muscle using a quantitative perfusion MRI technique.
MATERIALS AND METHODS: 17 premenopausal women with fibroids considered to be treated with MR-HIFU and 11 women with no fibroids were enrolled in the study. An extended MRI protocol of the pelvis was acquired for each subject. Later another MRI scan was performed with continuous intravenous infusion of oxytocin. The effect of oxytocin was analyzed from quantitative perfusion imaging. The study was registered in clinicaltrials.gov NCT03937401.
RESULTS: Oxytocin decreased the blood flow of each fibroid; the median blood flow of fibroid was 39.9 ml/100 g tissue/min without and 3.5 mL/100 g/min with oxytocin (p ≤ 0.0001). Oxytocin did not affect the blood flow of the myometrium in either group. Oxytocin increased the blood flow of the skeletal muscle in both groups (p = 0.04).
CONCLUSION: Oxytocin is effective in decreasing the blood flow in fibroids while having minor or no effect on the blood flow of normal myometrium. Routine use of oxytocin in HIFU therapy may make the therapy suitable to a larger group of women in a safe manner.

Entities:  

Keywords:  Fibroid; MR-HIFU; blood flow; contrast enhanced MRI; oxytocin

Mesh:

Substances:

Year:  2020        PMID: 33207939     DOI: 10.1080/02656736.2020.1846792

Source DB:  PubMed          Journal:  Int J Hyperthermia        ISSN: 0265-6736            Impact factor:   3.914


  1 in total

1.  Increased MR-guided high intensity focused ultrasound (MR-HIFU) sonication efficiency of uterine fibroids after carbetocin administration.

Authors:  Kimberley J Anneveldt; Heleen J van 't Oever; Inez M Verpalen; Ingrid M Nijholt; Wilbert Bartels; Jeroen R Dijkstra; Rolf D van den Hoed; Miranda van 't Veer-Ten Kate; Erwin de Boer; Sebastiaan Veersema; Judith A F Huirne; Joke M Schutte; Martijn F Boomsma
Journal:  Eur J Radiol Open       Date:  2022-03-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.