Literature DB >> 33207121

Positive Bubble Study in Severe COVID-19: Bubbles May Be Unrelated to Gas Exchange Impairment.

Erik R Swenson1, Susan R Hopkins2, Michael K Stickland3.   

Abstract

Entities:  

Mesh:

Year:  2021        PMID: 33207121      PMCID: PMC7874323          DOI: 10.1164/rccm.202010-3800LE

Source DB:  PubMed          Journal:  Am J Respir Crit Care Med        ISSN: 1073-449X            Impact factor:   21.405


× No keyword cloud information.
To the Editor: Data obtained using the multiple inert gas elimination technique show that hypoxemia in acute respiratory distress syndrome arises from regions with shunt and/or low / mismatch (1) but, more importantly, show no diffusion limitation of oxygen uptake into the pulmonary capillaries. Hypoxemia in patients with coronavirus disease (COVID-19)–associated lung disease may also be reasonably believed to result from / mismatch and shunt, but this has not been tested by definitive means. With this as brief background, we read the interesting study by Reynolds and colleagues (2), who used contrast-enhanced transcranial Doppler (TCD) after injection of agitated saline to detect transpulmonary transit of microbubbles as evidence for pulmonary microvascular dilatations in patients with severe COVID-19, a finding noted at autopsy (3). The authors made three key observations: 1) 83% of patients had detectable microbubbles with a median of 8 detected, 2) the PaO/FiO was inversely correlated with the number of microbubbles, and 3) the number of microbubbles was inversely correlated to lung compliance. On the basis of their findings, they suggest that these pulmonary microvascular dilatations may explain the disproportionate degree of hypoxemia in some patients with COVID-19–associated lung injury akin to the perfusion–diffusion limitation for oxygen uptake occurring in the greatly enlarged pulmonary microvascular dilations of hepatopulmonary syndrome, as discussed in the accompanying editorial by DuBrock and Krowka (4). We find several problems with the interpretation of these results. First, patent foramen ovale (PFO) is rather common, and because PFO presence was not examined in this study, we cannot rule out this as a contribution to their TCD microbubble detection. It would have been useful for the investigators to have performed TCD in patients with equally severe acute respiratory distress syndrome as a control group to detect whether the two conditions differ in this regard with their methodology. Second, the issue is not one of TCD sensitivity to detect microbubbles (5) but rather whether the microbubbles represent a cause of meaningful gas exchange derangement. For example, Stickland and colleagues (6) studied animals without PFO with a similar amount of bubble transit on transthoracic echocardiography, which are a result of naturally occurring intrapulmonary arterial–venous anastomoses. Despite a large amount of bubble contrast traversing the pulmonary circulation and appearing in the left ventricle, there was no evidence for a diffusion limitation of oxygen, and the actual shunt quantified by both 25 μm microspheres and the multiple inert gas elimination technique was small (<1.5% of Q̇). These data also showed that, although contrast echocardiography is extremely sensitive, it is nonspecific and frequently detects very small anatomical shunts that are <1% of Q̇ and of trivial importance for gas exchange. Consequently, the nonquantitative nature of transthoracic echocardiography and/or TCD does not permit any conclusions as to whether hypoxemia is caused by the putative microvascular dilatations described by Ackermann and colleagues (3) and others. Although the autopsy data show congested capillaries and slightly increased diameters, any comparison with the far greater vessel dilation (up to 100 μm) and the perfusion–diffusion limitation in hepatopulmonary syndrome is tenuous (4). It is more likely that the correlations of the TCD bubble score with compliance and the severity of hypoxemia as assessed by the PaO/FiO simply reflect the amount of lung involvement with shunt and low / ratios, with TCD bubble detection from a PFO and/or recruitment of intrapulmonary arterial–venous anastomoses because of hypoxia, higher Q̇, and/or increased pulmonary artery pressure (6).
  6 in total

Review 1.  Transcranial Doppler versus transthoracic echocardiography for the detection of patent foramen ovale in patients with cryptogenic cerebral ischemia: A systematic review and diagnostic test accuracy meta-analysis.

Authors:  Aristeidis H Katsanos; Theodora Psaltopoulou; Theodoros N Sergentanis; Alexandra Frogoudaki; Agathi-Rosa Vrettou; Ignatios Ikonomidis; Ioannis Paraskevaidis; John Parissis; Chrysa Bogiatzi; Christina Zompola; John Ellul; Nikolaos Triantafyllou; Konstantinos Voumvourakis; Athanassios P Kyritsis; Sotirios Giannopoulos; Anne W Alexandrov; Andrei V Alexandrov; Georgios Tsivgoulis
Journal:  Ann Neurol       Date:  2016-03-11       Impact factor: 10.422

2.  Intra-pulmonary arteriovenous anastomoses and pulmonary gas exchange: evaluation by microspheres, contrast echocardiography and inert gas elimination.

Authors:  Michael K Stickland; Vincent Tedjasaputra; Cameron Seaman; Desi P Fuhr; Sophie É Collins; Harrieth Wagner; Sean van Diepen; Bradley W Byers; Peter D Wagner; Susan R Hopkins
Journal:  J Physiol       Date:  2019-09-26       Impact factor: 5.182

3.  Pulmonary Vascular Endothelialitis, Thrombosis, and Angiogenesis in Covid-19.

Authors:  Maximilian Ackermann; Stijn E Verleden; Mark Kuehnel; Axel Haverich; Tobias Welte; Florian Laenger; Arno Vanstapel; Christopher Werlein; Helge Stark; Alexandar Tzankov; William W Li; Vincent W Li; Steven J Mentzer; Danny Jonigk
Journal:  N Engl J Med       Date:  2020-05-21       Impact factor: 91.245

4.  Ventilation-perfusion distributions in the adult respiratory distress syndrome.

Authors:  D R Dantzker; C J Brook; P Dehart; J P Lynch; J G Weg
Journal:  Am Rev Respir Dis       Date:  1979-11

5.  Bubble Trouble in COVID-19.

Authors:  Hilary M DuBrock; Michael J Krowka
Journal:  Am J Respir Crit Care Med       Date:  2020-10-01       Impact factor: 21.405

6.  Pulmonary Vascular Dilatation Detected by Automated Transcranial Doppler in COVID-19 Pneumonia.

Authors:  Alexandra S Reynolds; Alison G Lee; Joshua Renz; Katherine DeSantis; John Liang; Charles A Powell; Corey E Ventetuolo; Hooman D Poor
Journal:  Am J Respir Crit Care Med       Date:  2020-10-01       Impact factor: 21.405

  6 in total
  2 in total

Review 1.  Diffuse large B-cell lymphoma presenting as reversible intrapulmonary arteriovenous shunts with hypoxia, fever and progressive jaundice: a case report and literature review.

Authors:  Huan Hou; Cuiyan Guo; Chengli Que; Ligong Nie; Qi Zhang; Hong Zhao; Lin Nong; Wei Ma; Qian Wang; Zeyin Liang; Bingjie Wang; Jing Ma; Guangfa Wang
Journal:  BMC Pulm Med       Date:  2022-03-15       Impact factor: 3.317

2.  Cardiac index is associated with oxygenation in COVID-19 acute respiratory distress syndrome.

Authors:  Hooman D Poor; Kevin Rurak; Daniel Howell; Alison G Lee; Elena Colicino; Alexandra S Reynolds; Kaitlin Reilly; Thomas Tolbert; Ali Mustafa; Corey E Ventetuolo
Journal:  Pulm Circ       Date:  2021-05-26       Impact factor: 3.017

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.