Literature DB >> 33201827

Non-Invasive Real-Time Monitoring of Glucose Level Using Novel Microwave Biosensor Based on Triple-Pole CSRR.

Ala Eldin Omer, George Shaker, Safieddin Safavi-Naeini, Georges Alquie, Frederique Deshours, Hamid Kokabi, Raed M Shubair.   

Abstract

Planar microwave sensors are considered an attractive choice to noninvasively probe the dielectric attributes of biological tissues due to their low cost, simple fabrication, miniature scale, and minimum risk to human health. This paper develops and measures a novel microwave biosensor for non-invasive real-time monitoring of glucose level. The design comprises a rectangular plexiglass channel integrated on a triple-pole complementary split ring resonator (TP-CSRR). The proposed sensor operates in the centimeter-wave range 1-6 GHz and is manufactured using PCB on top of an FR4 dielectric substrate. The sensor elements are excited via a coupled microstrip transmission-line etched on the bottom side of the substrate. The integrated CSRR-based sensor is used as a near-field probe to non-invasively monitor the glucose level changes in the blood mimicking solutions of clinically relevant concentrations to Type-2 normal diabetes (70-120 mg/dL), by recording the frequency response of the harmonic reflection and transmission resonances. This indicates the sensor's capability of detecting small variations in the dielectric properties of the blood samples that are responsive to the electromagnetic fields. The proposed sensor is verified through practical measurements of the fabricated design. Experimental results obtained using a Vector Network Analyzer (VNA) demonstrate a sensitivity performance of about 6.2 dB/(mg/ml) for the developed triple-pole sensor that significantly outperforms the conventional single-pole and other proposed sensors in the literature in terms of the resonance amplitude resolution.

Entities:  

Year:  2020        PMID: 33201827     DOI: 10.1109/TBCAS.2020.3038589

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  3 in total

1.  Glucose level detection using millimetre-wave metamaterial-inspired resonator.

Authors:  Suhail Asghar Qureshi; Zuhairiah Zainal Abidin; N I M Elamin; Huda A Majid; Adel Y I Ashyap; Jamel Nebhen; M R Kamarudin; Chan Hwang See; R A Abd-Alhameed
Journal:  PLoS One       Date:  2022-06-29       Impact factor: 3.752

2.  Machine Learning Methods of Regression for Plasmonic Nanoantenna Glucose Sensing.

Authors:  Emilio Corcione; Diana Pfezer; Mario Hentschel; Harald Giessen; Cristina Tarín
Journal:  Sensors (Basel)       Date:  2021-12-21       Impact factor: 3.576

3.  RFID-Based Microwave Biosensor for Non-Contact Detection of Glucose Solution.

Authors:  Minjia Gao; Tian Qiang; Yangchuan Ma; Junge Liang; Yanfeng Jiang
Journal:  Biosensors (Basel)       Date:  2021-11-26
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.