Literature DB >> 33201549

An optimized b-value distribution for triexponential intravoxel incoherent motion (IVIM) in the liver.

Andreas Riexinger1, Jan Martin1, Andreas Wetscherek2, Tristan Anselm Kuder3, Michael Uder1, Bernhard Hensel4, Frederik Bernd Laun1.   

Abstract

PURPOSE: To find an optimized b-value distribution for reproducible triexponential intravoxel incoherent motion (IVIM) exams in the liver.
METHODS: A numeric optimization of b-value distributions was performed using the triexponential IVIM equation and 27 different IVIM parameter sets. Starting with an initially optimized distribution of 6 b-values, the number of b-values was increased stepwise. Each new b-value was chosen from a set of 64 predefined b-values based on the computed summed relative mean error of the fitted triexponential IVIM parameters. This process was repeated for up to 100 b-values. In simulations and in vivo measurements, optimized b-value distributions were compared to 4 representative distributions found in literature.
RESULTS: The first 16 optimized b-values were 0, 0.3, 0.3, 70, 200, 800, 70, 1, 3.5, 5, 70, 1.2, 6, 45, 1.5, and 60 in units of s/mm2 . Low b-values were much more frequent than high b-values. The optimized b-value distribution resulted in a higher fit stability compared to distributions used in literature in both, simulation and in vivo measurements. Using more than 6 b-values, ideally 16 or more, increased the fit stability considerably.
CONCLUSION: Using optimized b-values, the fit uncertainty in triexponential IVIM can be largely reduced. Ideally, 16 or more b-values should be acquired.
© 2020 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Keywords:  MRI; diffusion; intravoxel incoherent motion; liver; optimization; triexponential

Year:  2020        PMID: 33201549     DOI: 10.1002/mrm.28582

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

Review 1.  Diffusion-weighted MRI of the liver: challenges and some solutions for the quantification of apparent diffusion coefficient and intravoxel incoherent motion.

Authors:  Yi Xiang J Wang; Hua Huang; Cun-Jing Zheng; Ben-Heng Xiao; Olivier Chevallier; Wei Wang
Journal:  Am J Nucl Med Mol Imaging       Date:  2021-04-15

2.  Precision of region of interest-based tri-exponential intravoxel incoherent motion quantification and the role of the Intervoxel spatial distribution of flow velocities.

Authors:  Gregory Simchick; Diego Hernando
Journal:  Magn Reson Med       Date:  2022-08-15       Impact factor: 3.737

3.  b value and first-order motion moment optimized data acquisition for repeatable quantitative intravoxel incoherent motion DWI.

Authors:  Gregory Simchick; Ruiqi Geng; Yuxin Zhang; Diego Hernando
Journal:  Magn Reson Med       Date:  2022-01-28       Impact factor: 3.737

4.  Self-supervised neural network improves tri-exponential intravoxel incoherent motion model fitting compared to least-squares fitting in non-alcoholic fatty liver disease.

Authors:  Marian A Troelstra; Anne-Marieke Van Dijk; Julia J Witjes; Anne Linde Mak; Diona Zwirs; Jurgen H Runge; Joanne Verheij; Ulrich H Beuers; Max Nieuwdorp; Adriaan G Holleboom; Aart J Nederveen; Oliver J Gurney-Champion
Journal:  Front Physiol       Date:  2022-09-06       Impact factor: 4.755

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.