Literature DB >> 33196854

Comparison of in-phase and opposed-phase T1W gradient echo and T2W fast spin echo dixon chemical shift imaging for the assessment of non-neoplastic, benign neoplastic and malignant marrow lesions.

Asif Saifuddin1, Hassan Shafiq2, Karan Malhotra3, Rodney Santiago1, Ian Pressney4.   

Abstract

OBJECTIVE: The objective of this study is to compare T1-weighted gradient echo (T1W GrE: control technique) chemical shift imaging (CSI) with T2-weighted fast spin echo (T2W FSE: experimental technique) CSI for differentiating non-neoplastic and neoplastic marrow lesions.
MATERIALS AND METHODS: Patients undergoing MRI for various marrow lesions were investigated with T1W GrE and T2W FSE Dixon CSI. Signal intensity (SI) change between in-phase (IP) and opposed-phase (OP) sequences was calculated, and SI drop > 20% considered to represent non-neoplastic lesions while SI drop < 20% considered to represent neoplastic lesions. Final diagnosis was based on imaging features (n = 42) or histology (n = 43) and classified as non-neoplastic, benign neoplastic, and malignant neoplastic. Inter-observer and inter-technique agreement between 2 readers was calculated.
RESULTS: The study included 85 patients (44 males and 41 females; mean age 41.1 years, range 2-83 years). Final diagnosis included 19 (22.4%) non-neoplastic lesions, 27 (31.8%) benign neoplasms, and 39 (45.9%) malignant neoplasms. On T1W GrE CSI, 19-21 lesions were classed as non-neoplastic and 64-66 as neoplastic, while on T2W FSE Dixon CSI, 22-24 lesions were classed as non-neoplastic and 61-64 as neoplastic. Lesion classification matched between the 2 techniques in 91.8-96.5% of cases. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of T1W GrE CSI for differentiating non-neoplastic and neoplastic marrow lesions were 66.7-72.2%, 88.1-89.6%, 61.9-63.2%, 90.9-92.2%, and 84.7%, and of T2W FSE Dixon CSI were 72.2-77.8%, 85.1-86.6%, 58.3-59.1%, 92.1-93.4%, and 83.5%.
CONCLUSIONS: T1W GrE CSI and T2W FSE Dixon CSI produce similar results in the assessment of non-neoplastic and neoplastic marrow lesions.

Entities:  

Keywords:  Bone tumour; Chemical shift imaging; Dixon sequence; MRI

Mesh:

Year:  2020        PMID: 33196854     DOI: 10.1007/s00256-020-03663-x

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  4 in total

1.  Fat-only Dixon: how to use it in body MRI.

Authors:  Reza Salari; David H Ballard; Mark J Hoegger; Daniel Young; Anup S Shetty
Journal:  Abdom Radiol (NY)       Date:  2022-05-18

2.  Comparison of lumbar degenerative disc disease using conventional fast spin echo T2W MRI and T2 fast spin echo dixon sequences.

Authors:  Asif Saifuddin; Ramanan Rajakulasingam; Rodney Santiago; Mateen Siddiqui; Michael Khoo; Ian Pressney
Journal:  Br J Radiol       Date:  2021-03-08       Impact factor: 3.039

Review 3.  Society of Skeletal Radiology- white paper. Guidelines for the diagnostic management of incidental solitary bone lesions on CT and MRI in adults: bone reporting and data system (Bone-RADS).

Authors:  Connie Y Chang; Hillary W Garner; Shivani Ahlawat; Behrang Amini; Matthew D Bucknor; Jonathan A Flug; Iman Khodarahmi; Michael E Mulligan; Jeffrey J Peterson; Geoffrey M Riley; Mohammad Samim; Santiago A Lozano-Calderon; Jim S Wu
Journal:  Skeletal Radiol       Date:  2022-03-28       Impact factor: 2.128

4.  Differentiation between benign and malignant vertebral compression fractures using qualitative and quantitative analysis of a single fast spin echo T2-weighted Dixon sequence.

Authors:  Sebastien Bacher; Steven David Hajdu; Yael Maeder; Vincent Dunet; Tom Hilbert; Patrick Omoumi
Journal:  Eur Radiol       Date:  2021-05-26       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.