Are early palliative procedures providing an adequate long-term benefit in young cyanotic infants from developing countries, despite advances in surgery and interventions?

Pramod Sagar1, Kothandam Sivakumar1, Koneru L Umamaheshwar1, Bhushan Sonawane1, Asish R Mohakud1, Monica Rajendran1, Ravi Agarwal1, Roy Varghese1, Ejaz Ahamed Sheriff1.   

Abstract

OBJECTIVES: Ductal stents, right ventricular outflow tract stents, and aortopulmonary shunts are used to palliate newborns and infants with reduced pulmonary blood flow. Current long-term outcomes of these palliations from resource-restricted countries are unknown.
METHODS: This single-centre, retrospective, observational study analysed the technical success, immediate and late mortality, re-interventions, and length of palliation in infants ≤5 kg who underwent aortopulmonary shunts, ductal, and pulmonary outflow stents. Patients were grouped by their anatomy.
RESULTS: There were 69 infants who underwent one of the palliations. Technical success was 90% for aortopulmonary shunts (n = 10), 91% for pulmonary outflow stents (n = 11) and 100% for ductal stents (n = 48). Early mortality within 30 days in 12/69 patients was observed in 20% after shunts, 9% after pulmonary outflow stents, and 19% after ductal stents. Late mortality in 11 patients was seen in 20% after shunts, 18% after outflow stents, and 15% after ductal stents. Seven patients needed re-interventions; two following shunts, one following outflow stent, and four following ductal stents for hypoxia. Among the anatomical groups, 10/12 patients with pulmonary atresia, intact ventricular septum survived after valvotomy and ductal stenting. Survival to Glenn shunt after ductal stent for pulmonary atresia, intact ventricular septum and diminutive right ventricle was very low in two out of eight patients, but very good (100%) for other univentricular hearts. Among 35 patients with biventricular lesions, 22 survived to the next stage.
CONCLUSIONS: Cyanotic infants, despite undergoing technically successful palliation had a high inter-stage mortality irrespective of the type of palliation. Duct stenting in univentricular hearts and in pulmonary atresia with an intact ventricular septum and adequate sized right ventricle tended to have low mortality and better long-term outcome. Completion of biventricular repair after palliation was achieved only in 63% of patients, reflecting unique challenges in developing countries despite advances in intensive care and interventions.

Entities:  

Keywords:  Aortopulmonary shunt; arterial duct stenting; developing economies; inter-stage mortality; right ventricular outflow tract stenting

Mesh:

Year:  2020        PMID: 33191897     DOI: 10.1017/S1047951120003947

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093