Literature DB >> 33184847

Instabilities of the pH gradient in carrier ampholyte-based isoelectric focusing: Elucidation of the contributing electrokinetic processes by computer simulation.

Wolfgang Thormann1, Richard A Mosher2.   

Abstract

Electrokinetic processes that lead to pH gradient instabilities in carrier ampholyte-based IEF are reviewed. In addition to electroosmosis, there are four of electrophoretic nature, namely (i) the stabilizing phase with the plateau phenomenon, (ii) the gradual isotachophoretic loss of carrier ampholytes at the two column ends in presence of electrode solutions, (iii) the inequality of the mobilities of positively and negatively charged species of ampholytes, and (iv) the continuous penetration of carbonate from the catholyte into the focusing column. The impact of these factors to cathodic and anodic drifts was analyzed by simulation of carrier ampholyte-based focusing in closed and open columns. Focusing under realistic conditions within a 5 cm long capillary in which three amphoteric low molecular mass dyes were focused in a pH 3-10 gradient formed by 140 carrier ampholytes was investigated. In open columns, electroosmosis displaces the entire gradient toward the cathode or anode whereas the electrophoretic processes act bidirectionally with a transition around pH 4 (drifts for pI > 4 and pI < 4 typically toward the cathode and anode, respectively). The data illustrate that focused zones of carrier ampholytes have an electrophoretic flux and that dynamic simulation can be effectively used to assess the magnitude of each of the electrokinetic destabilizing factors and the resulting drift for a combination of these effects. Predicted drifts of focused marker dyes are compared to those observed experimentally in a setup with coated capillary and whole column optical imaging.
© 2020 Wiley-VCH GmbH.

Entities:  

Keywords:  Cathodic drift; Electroosmosis; Isoelectric focusing; Isotachophoresis; Simulation

Mesh:

Substances:

Year:  2020        PMID: 33184847     DOI: 10.1002/elps.202000269

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  2 in total

1.  The effect of pH adjusted electrolytes on capillary isoelectric focusing assessed by high-resolution dynamic computer simulation.

Authors:  Anna Takácsi-Nagy; Ferenc Kilár; Wolfgang Thormann
Journal:  Electrophoresis       Date:  2021-12-21       Impact factor: 3.595

Review 2.  Dynamic computer simulations of electrophoresis: 2010-2020.

Authors:  Wolfgang Thormann; Richard A Mosher
Journal:  Electrophoresis       Date:  2021-08-02       Impact factor: 3.595

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.