Literature DB >> 3318339

Ferrite-enhanced MR imaging of hepatic lymphoma: an experimental study in rats.

R Weissleder1, D D Stark, C C Compton, J Wittenberg, J T Ferrucci.   

Abstract

The purpose of this investigation was to define the potential of unenhanced and ferrite-enhanced MR to detect hepatic lymphoma. Rats were implanted with diffuse and focal hepatic lymphoma. Both in vitro measurements of relaxation times and in vivo MR imaging of normal liver and of diffuse and focal hepatic lymphoma were compared. Diffuse infiltrative hepatic lymphoma showed increased T1 (45%) and T2 (41%) relaxation times in vitro, but could not be distinguished from normal control livers on in vivo spin echo (SE) images with a repetition time of 500 msec and an echo time of 30 msec (SE 500/30) or SE 1500/60 images. Focal hepatic lymphoma showed increased T1 (185%) and T2 (115%) relaxation times relative to normal liver tissue. Focal hepatic lymphoma was undetectable on unenhanced SE 500/30 MR images (contrast-to-noise ratio, C/N = 0.4) and was slightly hyperintense on SE 1500/60 images (C/N = 1.1). Ferrite (50 mumol Fe/kg) was administered to improve tissue contrast. In normal control animals, T2 of liver in vitro decreased from 29.3 +/- 3.3 msec to 11.1 +/- 1.2 msec, and image signal-to-noise ratio (S/N) of liver in vivo decreased from 16.1 +/- 2.4 to 2.8 +/- 0.3 (p less than .005). Ferrite-enhanced diffuse hepatic lymphoma showed in vitro T2 values and in vivo MR image S/N values indistinguishable from those of normal control animals. The T2 of focal hepatic lymphoma was essentially unaltered by ferrite. On SE 500/30 images, focal hepatic lymphoma became readily detectable, quantitated by a 35-fold increase in tumor-liver C/N. We conclude that clinical studies are warranted to determine the value of ferrite enhanced MR as a technique for the enhanced detection of focal hepatic lymphoma.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3318339     DOI: 10.2214/ajr.149.6.1161

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  5 in total

Review 1.  Multifunctional magnetic nanoparticles for targeted imaging and therapy.

Authors:  Jason R McCarthy; Ralph Weissleder
Journal:  Adv Drug Deliv Rev       Date:  2008-04-10       Impact factor: 15.470

Review 2.  Targeted nanoagents for the detection of cancers.

Authors:  Jason R McCarthy; Jayeeta Bhaumik; Mark R Karver; S Sibel Erdem; Ralph Weissleder
Journal:  Mol Oncol       Date:  2010-09-08       Impact factor: 6.603

Review 3.  Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging.

Authors:  Omid Veiseh; Jonathan W Gunn; Miqin Zhang
Journal:  Adv Drug Deliv Rev       Date:  2009-11-10       Impact factor: 15.470

Review 4.  In vivo molecular imaging of vascular stress.

Authors:  Marius C Wick; Christian Kremser; Stefan Frischauf; Georg Wick
Journal:  Cell Stress Chaperones       Date:  2008-05-09       Impact factor: 3.667

5.  Monoclonal antibody A7-superparamagnetic iron oxide as contrast agent of MR imaging of rectal carcinoma.

Authors:  A Toma; E Otsuji; Y Kuriu; K Okamoto; D Ichikawa; A Hagiwara; H Ito; T Nishimura; H Yamagishi
Journal:  Br J Cancer       Date:  2005-07-11       Impact factor: 7.640

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.