Reproducibility of Aorta Segmentation on 4D Flow MRI in Healthy Volunteers.

Joe F Juffermans1, Jos J M Westenberg1, Pieter J van den Boogaard1, Arno A W Roest2, Hans C van Assen1, Roel L F van der Palen2, Hildo J Lamb1.   

Abstract

BACKGROUND: Hemodynamic aorta parameters can be derived from 4D flow MRI, but this requires lumen segmentation. In both commercially available and research 4D flow MRI software tools, lumen segmentation is mostly (semi-)automatically performed and subsequently manually improved by an observer. Since the segmentation variability, together with 4D flow MRI data and image processing algorithms, will contribute to the reproducibility of patient-specific flow properties, the observer's lumen segmentation reproducibility and repeatability needs to be assessed.
PURPOSE: To determine the interexamination, interobserver reproducibility, and intraobserver repeatability of aortic lumen segmentation on 4D flow MRI. STUDY TYPE: Prospective and retrospective. POPULATION: A healthy volunteer cohort of 10 subjects who underwent 4D flow MRI twice. Also, a clinical cohort of six subjects who underwent 4D flow MRI once. FIELD STRENGTH/SEQUENCE: 3T; time-resolved three-directional and 3D velocity-encoded sequence (4D flow MRI). ASSESSMENT: The thoracic aorta was segmented on the 4D flow MRI in five systolic phases. By positioning six planes perpendicular to a segmentation's centerline, the aorta was divided into five segments. The volume, surface area, centerline length, maximal diameter, and curvature radius were determined for each segment. STATISTICAL TESTS: To assess the reproducibility, the coefficient of variation (COV), Pearson correlation coefficient (r), and intraclass correlation coefficient (ICC) were calculated.
RESULTS: The interexamination and interobserver reproducibility and intraobserver repeatability were comparable for each parameter. For both cohorts there was very good reproducibility and repeatability for volume, surface area, and centerline length (COV = 10-32%, r = 0.54-0.95 and ICC = 0.65-0.99), excellent reproducibility and repeatability for maximal diameter (COV = 3-11%, r = 0.94-0.99, ICC = 0.94-0.99), and good reproducibility and repeatability for curvature radius (COV = 25-62%, r = 0.73-0.95, ICC = 0.84-0.97). DATA
CONCLUSION: This study demonstrated no major reproducibility and repeatability limitations for 4D flow MRI aortic lumen segmentation. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.
© 2020 The Authors. Journal of Magnetic Resonance Imaging published by Wiley Periodicals LLC. on behalf of International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  4D flow MRI; aorta; aortic diameter; repeatability; reproducibility; segmentation

Mesh:

Year:  2020        PMID: 33179389      PMCID: PMC7984392          DOI: 10.1002/jmri.27431

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  28 in total

1.  Quantitative 2D and 3D phase contrast MRI: optimized analysis of blood flow and vessel wall parameters.

Authors:  A F Stalder; M F Russe; A Frydrychowicz; J Bock; J Hennig; M Markl
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

Review 2.  An image-based modeling framework for patient-specific computational hemodynamics.

Authors:  Luca Antiga; Marina Piccinelli; Lorenzo Botti; Bogdan Ene-Iordache; Andrea Remuzzi; David A Steinman
Journal:  Med Biol Eng Comput       Date:  2008-11-11       Impact factor: 2.602

3.  Efficient triple-VENC phase-contrast MRI for improved velocity dynamic range.

Authors:  Liliana E Ma; Michael Markl; Kelvin Chow; Alireza Vali; Can Wu; Susanne Schnell
Journal:  Magn Reson Med       Date:  2019-08-18       Impact factor: 4.668

4.  Fully automated 3D aortic segmentation of 4D flow MRI for hemodynamic analysis using deep learning.

Authors:  Haben Berhane; Michael Scott; Mohammed Elbaz; Kelly Jarvis; Patrick McCarthy; James Carr; Chris Malaisrie; Ryan Avery; Alex J Barker; Joshua D Robinson; Cynthia K Rigsby; Michael Markl
Journal:  Magn Reson Med       Date:  2020-03-13       Impact factor: 4.668

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Interobserver and intraobserver variability in measuring the tortuosity of the thoracic aorta on computed tomography.

Authors:  Chun-Ku Chen; Hsiao-Ping Chou; Chao-Yu Guo; Hsiao-Ting Chang; Ying-Yueh Chang; I-Ming Chen; Mei-Han Wu; Chun-Che Shih
Journal:  J Vasc Surg       Date:  2018-04-25       Impact factor: 4.268

7.  MRI hemodynamic markers of progressive bicuspid aortic valve-related aortic disease.

Authors:  Michael D Hope; Monica Sigovan; S Jarrett Wrenn; David Saloner; Petter Dyverfeldt
Journal:  J Magn Reson Imaging       Date:  2013-10-29       Impact factor: 4.813

8.  Heartbeat-related distension and displacement of the thoracic aorta in healthy volunteers.

Authors:  Fabian Rengier; Tim Frederik Weber; Verena Henninger; Dittmar Böckler; Hardy Schumacher; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Eur J Radiol       Date:  2010-09-17       Impact factor: 3.528

9.  Aneurysm growth occurs at region of low wall shear stress: patient-specific correlation of hemodynamics and growth in a longitudinal study.

Authors:  Loic Boussel; Vitaliy Rayz; Charles McCulloch; Alastair Martin; Gabriel Acevedo-Bolton; Michael Lawton; Randall Higashida; Wade S Smith; William L Young; David Saloner
Journal:  Stroke       Date:  2008-08-07       Impact factor: 7.914

10.  Highly accelerated 4D flow cardiovascular magnetic resonance using a pseudo-spiral Cartesian acquisition and compressed sensing reconstruction for carotid flow and wall shear stress.

Authors:  Eva S Peper; Lukas M Gottwald; Qinwei Zhang; Bram F Coolen; Pim van Ooij; Aart J Nederveen; Gustav J Strijkers
Journal:  J Cardiovasc Magn Reson       Date:  2020-01-20       Impact factor: 5.364

View more
  3 in total

1.  Ascending aorta curvature and flow displacement are associated with accelerated aortic growth at long-term follow-up: A MRI study in Marfan and thoracic aortic aneurysm patients.

Authors:  M J P van Hout; J F Juffermans; H J Lamb; E S J Kröner; P J van den Boogaard; M J Schalij; I A Dekkers; A J Scholte; J J Westenberg
Journal:  Int J Cardiol Heart Vasc       Date:  2021-12-13

2.  4D flow cardiovascular magnetic resonance derived energetics in the Fontan circulation correlate with exercise capacity and CMR-derived liver fibrosis/congestion.

Authors:  Arno A W Roest; Hildo J Lamb; Friso M Rijnberg; Jos J M Westenberg; Hans C van Assen; Joe F Juffermans; Lucia J M Kroft; Pieter J van den Boogaard; Covadonga Terol Espinosa de Los Monteros; Evangeline G Warmerdam; Tim Leiner; Heynric B Grotenhuis; Monique R M Jongbloed; Mark G Hazekamp
Journal:  J Cardiovasc Magn Reson       Date:  2022-03-28       Impact factor: 6.903

3.  Does the Internal Carotid Artery Attenuate Blood-Flow Pulsatility in Small Vessel Disease? A 7 T 4D-Flow MRI Study.

Authors:  Rick J van Tuijl; Ynte M Ruigrok; Lennart J Geurts; Irene C van der Schaaf; Geert Jan Biessels; Gabriël J E Rinkel; Birgitta K Velthuis; Jaco J M Zwanenburg
Journal:  J Magn Reson Imaging       Date:  2022-01-07       Impact factor: 5.119

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.