Literature DB >> 33167228

Screen-printed anion-exchange solid-phase extraction: A new strategy for point-of-care determination of angiotensin receptor blockers.

Ali Farahani1, Shamim Azimi2, Atena Tajaddodi3, Aristides Docoslis2, Camellia Tashakori4.   

Abstract

A miniaturized system of anion exchange solid phase extraction (SPE) based on a screen-printed electrode was developed as a point of care (POC) device for extraction and quantitative determination of anionic analytes. Nylon 6/polyaniline nanofibers were fabricated by electrospinning and in-situ oxidative polymerization techniques coated on a screen-printed working electrode and characterized by Fourier-transform infrared spectroscopy (FTIR) and scanning electron microscopy (SEM) methods. The effects of essential parameters such as desorption conditions, pH of the sample solution, adsorption voltage, adsorption time, and salt concentration on the performance of the method were investigated. To evaluate the performance of the system, angiotensin ΙΙ receptor antagonists, including valsartan, losartan, and irbesartan, were selected as model compounds and analyzed by HPLC/UV after extraction. The limits of detection and quantification were ranging between 0.4 and 0.9 μg L-1 and 1.3-3.0 μg L-1, respectively. The linear dynamic range for Losartan, Irbesartan, and Valsartan was 2-400, 4-1000, and 2-400 μg L-1, respectively, with R2 > 0.991. Finally, the method was applied for the determination of ARA-IIs in human blood plasma samples, and relative recoveries in the range of 89.0-107.8% with relative standard deviation (RSDs (≤8.9% were obtained.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Angiotensin ΙΙ receptor antagonists; Ion exchange solid phase extraction; Nanofibers; Nylon 6/polyaniline; Screen-printed electrode

Mesh:

Substances:

Year:  2020        PMID: 33167228     DOI: 10.1016/j.talanta.2020.121518

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Developing an integrated microfluidic and miniaturized electrochemical biosensor for point of care determination of glucose in human plasma samples.

Authors:  Shamim Azimi; Ali Farahani; Aristides Docoslis; Sahar Vahdatifar
Journal:  Anal Bioanal Chem       Date:  2021-01-02       Impact factor: 4.142

Review 2.  Recent developments and trends of automatic nucleic acid detection systems.

Authors:  Xujun Yuan; Guodong Sui; Dawei Zhang; Min Chen; Wang Zhao
Journal:  J Biosaf Biosecur       Date:  2022-02-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.