Literature DB >> 33165669

Difference of vascular healing between bioabsorbable-polymer and durable-polymer new generation drug-eluting stents: an optical coherence tomographic analysis.

Yutaka Matsuhiro1, Daisuke Nakamura2, Ryu Shutta1, Akito Kawamura1, Hitoshi Nakamura1, Naotaka Okamoto1, Yasuharu Matsunaga-Lee1, Masamichi Yano1, Yasuyuki Egami1, Yasushi Sakata2, Masami Nishino3, Jun Tanouchi1.   

Abstract

The comparison of bioabsorbable-polymer and durable-polymer stents has continued to be debated, and there is ongoing concern regarding vascular healing and late stent thrombosis. This study compared the vascular healing at 8-month follow-up by optical coherence tomography (OCT) between 4 different kinds of new generation drug-eluting stents (DESs). We enrolled 112 patients (112 de novo lesions) who underwent OCT guided percutaneous coronary intervention with 4 kinds of new generation DESs including bioabsorbable-polymer everolimus-eluting stents (BP-EESs), bioabsorbable-polymer sirolimus-eluting stents (BP-SESs), durable-polymer everolimus-eluting stents (DP-EESs), and durable-polymer zotarolimus-eluting stents (DP-ZESs) and an 8-month follow-up angiogram and OCT were performed between July 2016 and April 2018. We divided them into two groups, namely BP and DP groups. We compared the OCT parameters including the percentage of uncovered struts, malapposed struts and the mean neointimal hyperplasia (NIH) thickness between the two groups. BP group consisted of 51 lesions (BP-EESs were used in 27, BP-SESs in 24 lesions) and DP group consisted of 61 lesions (DP-EESs were used in 35 and DP-ZESs in 26 lesions). The percentage of uncovered struts and malapposed struts were significantly lower (7.2 ± 8.9 vs. 15.0 ± 17.1%, p = 0.01, 0.9 ± 1.7 vs. 2.7 ± 5.2%, p = 0.03) and the mean NIH thickness was significantly thicker in BP group than DP group (112 ± 54 vs. 83 ± 31 µm, p < 0.01). The present OCT study demonstrated that uncovered struts and malapposed struts were less common with bioabsorbable-polymer stents than with durable-polymer stents.

Entities:  

Keywords:  Bioabsorbable polymer; Drug-eluting stent; Durable-polymer; Optical coherence tomography; Vascular healing

Year:  2020        PMID: 33165669     DOI: 10.1007/s10554-020-02094-y

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  1 in total

1.  Early vascular healing of ultra-thin strut polymer-free sirolimus-eluting stents in acute coronary syndrome: USUI-ACS study.

Authors:  Yutaka Matsuhiro; Yasuyuki Egami; Naotaka Okamoto; Masaya Kusuda; Takashige Sakio; Hiroaki Nohara; Hiroki Sugae; Shodai Kawanami; Akito Kawamura; Kohei Ukita; Hitoshi Nakamura; Koji Yasumoto; Masaki Tsuda; Yasuharu Matsunaga-Lee; Masamichi Yano; Masami Nishino; Jun Tanouchi
Journal:  Cardiovasc Interv Ther       Date:  2022-04-27
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.