Literature DB >> 33156379

Impact of Annulus-Sparing on Surgical Adequacy of Pulmonary Valve in Complete Repair of Tetralogy of Fallot with Right Ventricular Outflow Tract Incision.

Xianchao Jiang1, Jinyang Liu1, Bo Peng1, Heng Zhang2, Shoujun Li1, Jun Yan1, Qiang Wang3,4.   

Abstract

Today, strategy of repair remains controversial and rare analyses on annular integrity associated with outcomes in complete repair by RVOT incision were performed in a large TOF cohort in China. This is a retrospective cohort study involving patients with TOF who had undergone complete repair by RVOT incision between January 2012 and December 2017 in Fuwai hospital. The primary outcome was a composite of reintervention, significant pulmonary regurgitation (PR) and significant annular peak gradient (APG). Multivariate Cox proportional-hazards model analyses were used to assess the relationships between annular integrity and outcomes. In total, 1673 survival patients with the median age of 318 days were included, and 1002 were male. During a median follow-up of 49 months, 538 participants developed the primary outcome (27 reinterventions). Multivariate Cox analyses showed that compared with AS, TAP was associated with an increased risk of primary outcome (adjusted HR, 1.94 [95% CI 1.60-2.37]) and the results remained unchanged even in most subgroups defined. In secondary outcomes analyses, TAP is associated with a higher risk of reintervention (adjusted HR, 3.32 [95% CI 1.25-8.79]) and significant PR (adjusted HR, 2.51 [95% CI 2.00-3.16]). However, TAP is not associated with a decreased risk of significant APG (adjusted HR, 1.33 [95% CI 0.94-1.88]). PVA integrity preservation is important in complete repair of TOF with RVOT incision. TAP is associated with a higher risk of reintervention and significant PR, and with a similar risk of significant APG. Significant APG in AS patients at discharge has a downtrend over time.

Entities:  

Keywords:  Annulus-sparing; Right ventricular outflow tract incision; Tetralogy of Fallot; Transannular patch

Mesh:

Year:  2020        PMID: 33156379     DOI: 10.1007/s00246-020-02493-x

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  1 in total

1.  A new pulmonary valve cusp plasty technique markedly decreases transannular patch rate and improves midterm outcomes of tetralogy of Fallot repair.

Authors:  Zhongdong Hua; Shoujun Li; Liqing Wang; Shengshou Hu; De Wang
Journal:  Eur J Cardiothorac Surg       Date:  2011-03-31       Impact factor: 4.191

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.