Literature DB >> 33150001

Kilohertz retinal FF-SS-OCT and flood imaging with hardware-based adaptive optics.

Denise Valente1, Kari V Vienola1, Robert J Zawadzki1,2, Ravi S Jonnal1.   

Abstract

A retinal imaging system was designed for full-field (FF) swept-source (SS) optical coherence tomography (OCT) with cellular resolution. The system incorporates a real-time adaptive optics (AO) subsystem and a very high-speed CMOS sensor, and is capable of acquiring volumetric images of the retina at rates up to 1 kHz. While digital aberration correction (DAC) is an attractive potential alternative to AO, it has not yet been shown to provide resolution allowing visualization of cones in the fovea, where early detection of functional deficits is most critical. Here we demonstrate that FF-SS-OCT with hardware AO permits resolution of foveal cones, imaged at eccentricities of 1° and 2°, with volume rates adequate to measure light-evoked changes in photoreceptors. With the reference arm blocked, the system can operate as a kilohertz AO flood illumination fundus camera with adjustable temporal coherence and is expected to allow measurement of light-evoked changes caused by common path interference in photoreceptor outer segments (OS). In this paper, we describe the system's optical design, characterize its performance, and demonstrate its ability to produce images of the human photoreceptor mosaic.
© 2020 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2020        PMID: 33150001      PMCID: PMC7587251          DOI: 10.1364/BOE.403509

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.562


  44 in total

1.  Spectral-domain phase microscopy.

Authors:  Michael A Choma; Audrey K Ellerbee; Changhuei Yang; Tony L Creazzo; Joseph A Izatt
Journal:  Opt Lett       Date:  2005-05-15       Impact factor: 3.776

2.  Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation.

Authors:  Maciej Wojtkowski; Vivek Srinivasan; Tony Ko; James Fujimoto; Andrzej Kowalczyk; Jay Duker
Journal:  Opt Express       Date:  2004-05-31       Impact factor: 3.894

3.  Optical coherence angiography.

Authors:  Shuichi Makita; Youngjoo Hong; Masahiro Yamanari; Toyohiko Yatagai; Yoshiaki Yasuno
Journal:  Opt Express       Date:  2006-08-21       Impact factor: 3.894

4.  Holoscopy--holographic optical coherence tomography.

Authors:  Dierck Hillmann; Christian Lührs; Tim Bonin; Peter Koch; Gereon Hüttmann
Journal:  Opt Lett       Date:  2011-07-01       Impact factor: 3.776

Review 5.  Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited].

Authors:  Michael Pircher; Robert J Zawadzki
Journal:  Biomed Opt Express       Date:  2017-04-19       Impact factor: 3.732

6.  Combined hardware and computational optical wavefront correction.

Authors:  Fredrick A South; Kazuhiro Kurokawa; Zhuolin Liu; Yuan-Zhi Liu; Donald T Miller; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2018-05-08       Impact factor: 3.732

7.  Simple approach for aberration-corrected OCT imaging of the human retina.

Authors:  Helge Sudkamp; Dierck Hillmann; Peter Koch; Malte Vom Endt; Hendrik Spahr; Michael Münst; Clara Pfäffle; Reginald Birngruber; Gereon Hüttmann
Journal:  Opt Lett       Date:  2018-09-01       Impact factor: 3.776

8.  High-resolution in-vivo human retinal imaging using full-field OCT with optical stabilization of axial motion.

Authors:  Pedro Mecê; Jules Scholler; Kassandra Groux; Claude Boccara
Journal:  Biomed Opt Express       Date:  2019-12-23       Impact factor: 3.732

Review 9.  Imaging single cells in the living retina.

Authors:  David R Williams
Journal:  Vision Res       Date:  2011-05-10       Impact factor: 1.886

10.  Distribution of cone density, spacing and arrangement in adult healthy retinas with adaptive optics flood illumination.

Authors:  Richard Legras; Alain Gaudric; Kelly Woog
Journal:  PLoS One       Date:  2018-01-16       Impact factor: 3.240

View more
  4 in total

1.  Simultaneous directional full-field OCT using path-length and carrier multiplexing.

Authors:  Denise Valente; Kari V Vienola; Robert J Zawadzki; Ravi S Jonnal
Journal:  Opt Express       Date:  2021-09-27       Impact factor: 3.833

Review 2.  Toward a clinical optoretinogram: a review of noninvasive, optical tests of retinal neural function.

Authors:  Ravi S Jonnal
Journal:  Ann Transl Med       Date:  2021-08

3.  Reflective mirror-based line-scan adaptive optics OCT for imaging retinal structure and function.

Authors:  Vimal Prabhu Pandiyan; Xiaoyun Jiang; James A Kuchenbecker; Ramkumar Sabesan
Journal:  Biomed Opt Express       Date:  2021-08-27       Impact factor: 3.732

Review 4.  The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.

Authors:  Palaiologos Alexopoulos; Chisom Madu; Gadi Wollstein; Joel S Schuman
Journal:  Front Med (Lausanne)       Date:  2022-06-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.