Literature DB >> 33146861

Artifact reduction by using alternating polarity stimulus pairs in intraoperative peripheral nerve action potential recording.

Gang Wu1, Allan Belzberg2, Jessica Nance3, Sergio Gutierrez-Hernandez3, Eva K Ritzl3, Matthias Ringkamp2.   

Abstract

Intraoperative nerve action potential (NAP) recording permits direct study of an injured nerve for functional assessment of lesions in continuity. Stimulus artifact contamination often hampers NAP recording and interferes with its interpretation. In the present study, we evaluated the artifact reduction method using alternating polarity in peripheral nerve recording. Our study was conducted under controlled conditions in laboratory animals. NAPs were recorded from surgically exposed median or ulnar nerves. For the artifact reduction method with alternating polarity, two sequential recordings, one with normal and one with reversed stimulus polarity, were acquired and the signals from this recording pair were averaged. Simulation was also performed to further evaluate the effects of alternating polarity on the waveforms. The results are as follows: First, we found that this method worked for recordings with unsaturated electrical stimulus artifacts. Second, slightly unequal latencies occurred in an NAP pair, and this inequality contributed to a minimal loss of NAP amplitudes when averaging the two recordings. Third, perfect artifact cancelation and minimal signal loss were also demonstrated by simulation. Finally, we applied the method during nerve inching and demonstrated its usefulness in intraoperative NAP recordings as the method made the recording more resilient to short conduction distances. Thus, our findings demonstrate that this artifact reduction method can be used as a supplemental tool together with our previously described bridge grounding technique or the nonlifting nerve recording configuration to further improve intraoperative peripheral nerve recording. The method can be applied in clinical settings.
© 2020. Springer Nature B.V.

Entities:  

Keywords:  Alternating polarity; Artifact reduction; Intraoperative nerve recording; Nerve action potential; Peripheral nerve surgery; Stimulus artifact

Mesh:

Year:  2020        PMID: 33146861      PMCID: PMC8093315          DOI: 10.1007/s10877-020-00613-9

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   1.977


  1 in total

1.  Imaging the effective networks associated with cortical function through intracranial high-frequency stimulation.

Authors:  Andrei Barborica; Irina Oane; Cristian Donos; Andrei Daneasa; Felicia Mihai; Constantin Pistol; Aurelia Dabu; Adina Roceanu; Ioana Mindruta
Journal:  Hum Brain Mapp       Date:  2021-12-14       Impact factor: 5.038

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.