Literature DB >> 33146797

Accelerating acquisition of readout-segmented echo planar imaging with a simultaneous multi-slice (SMS) technique for diagnosing breast lesions.

Yiqi Hu1, Chenao Zhan1, Zhenlu Yang1, Xiaoyong Zhang2, Huiting Zhang3, Wei Liu4, Liming Xia1, Tao Ai5.   

Abstract

OBJECTIVES: To investigate the feasibility and effectiveness of SMS rs-EPI for evaluating breast lesions.
METHODS: This prospective study was approved by IRB. Ninety-six patients had 102 histopathologically verified lesions (80 malignant and 22 benign) that were evaluated. Conventional rs-EPI and SMS rs-EPI data were acquired on a 3T scanner. Mean kurtosis (MK), mean diffusion (MD), and apparent diffusion coefficient (ADC) values were quantitatively calculated for each lesion on both sequences. Images were qualitatively and quantitatively analyzed with respect to image sharpness, geometric distortion, lesion conspicuity, anatomic structure, overall image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Student's t test, Pearson correlation, receiver operating characteristic curve, Wilcoxon rank sum test, and paired-sample t tests were used for statistical analysis.
RESULTS: Compared to conventional rs-EPI, the acquisition time of SMS rs-EPI was markedly reduced (2:17 min vs 4:27 min). Pearson's correlations showed excellent linear relationships for each parameter between conventional rs-EPI and SMS rs-EPI (MK, r = 0.908; MD, r = 0.938; and ADC, r = 0.975; p < 0.01 for all). Furthermore, SMS rs-EPI had similar diagnostic performance compared with conventional rs-EPI. SMS rs-EPI had comparable visual image quality as conventional rs-EPI, with excellent inter-reader reliability (ICC = 0.851-0.940). No differences existed between conventional rs-EPI and SMS rs-EPI for either SNR or CNR (p > 0.05).
CONCLUSIONS: Applying the SMS technique can significantly reduce the acquisition time and produce similar diagnostic accuracy while generating comparable image quality as the conventional rs-EPI. KEY POINTS: • SMS rs-EPI reduces scan time from 4:27 min to 2:17 min compared with conventional rs-EPI. • SMS rs-EPI has a comparable diagnostic performance to conventional rs-EPI in the differentiation between malignant and benign breast lesions. • SMS rs-EPI demonstrates comparable image quality to conventional rs-EPI with shorter scan time.

Entities:  

Keywords:  Breast neoplasms; Echo planar imaging; Signal-to-noise ratio

Year:  2020        PMID: 33146797     DOI: 10.1007/s00330-020-07393-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  3 in total

Review 1.  Diffusion Breast MRI: Current Standard and Emerging Techniques.

Authors:  Ashley M Mendez; Lauren K Fang; Claire H Meriwether; Summer J Batasin; Stéphane Loubrie; Ana E Rodríguez-Soto; Rebecca A Rakow-Penner
Journal:  Front Oncol       Date:  2022-07-08       Impact factor: 5.738

2.  Image quality and whole-lesion histogram and texture analysis of diffusion-weighted imaging of breast MRI based on advanced ZOOMit and simultaneous multislice readout-segmented echo-planar imaging.

Authors:  Kun Sun; Hong Zhu; Bingqing Xia; Xinyue Li; Weimin Chai; Caixia Fu; Benkert Thomas; Wei Liu; Robert Grimm; Weiland Elisabeth; Fuhua Yan
Journal:  Front Oncol       Date:  2022-08-12       Impact factor: 5.738

3.  Improved Readout-Segmented Echo-Planner Diffusion-Weighted Magnetic Resonance Imaging of Nasopharyngeal Carcinoma Using Simultaneous Multislice Acquisitions at 3 T.

Authors:  Qiao Li; TingTing Jiang; TingTing Wang; Yan Huang; XiaoXin Hu; Ling Zhang; Wei Liu; CaiXia Fu; YaJia Gu
Journal:  J Comput Assist Tomogr       Date:  2022-04-26       Impact factor: 2.081

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.