Literature DB >> 33146629

Evaluation of heart rate variability, blood pressure and lipid profile alterations from dual transceiver mobile phone radiation exposure.

Jamil Dauda Usman1,2, Mikail Umar Isyaku3, Adesoji Adedipe Fasanmade2.   

Abstract

OBJECTIVES: Electromagnetic fields have been reported to alter electrical activities in the brain and heart. However, there is paucity of information on the potential functional alterations that magnetic fields from mobile phone could cause to the heart. This study investigated heart rate variability (HRV), blood pressure (BP) and lipid profile in Wistar rats exposed to electromagnetic field radiation from a dual transceiver mobile phone (DTrMP).
METHODS: Twenty-one male albino Wistar rats (140-180 g) were randomly assigned to two major groups positioned 5 m apart as follows: control: no phone (n=7) and treatment group (n=14) continuously exposed to electromagnetic field from Tecno T312 DTrMP 900/1800 MHz set in silence mode. Experimental treatment consisted in 10 min calls/day, directed to this device for a period of six weeks. Seven animals from the treatment group were allowed to recover for a period of two weeks after exposure. HRV, systolic, diastolic and mean arterial BP were noninvasively investigated, while serum lipid profile and heart tissue nitric oxide (NO) activities were determined using standard procedures.
RESULTS: There was significant (p<0.05) increase in systolic, diastolic, mean arterial BP and a decrease in HRV. Serum high density lipoproteins decreased, while total cholesterol, atherogenic indices, and heart NO levels increased significantly in the radiation exposed animals. The alterations observed in exposed animals remained unchanged even after the recovery period.
CONCLUSIONS: These results suggest that exposure to electromagnetic radiation from dual transceiver mobile phones could be a risk factor to increase in blood pressure.
© 2020 Jamil Dauda Usman et al., published by De Gruyter, Berlin/Boston.

Entities:  

Keywords:  blood pressure; heart rate variability; lipid profile; mobile phone electromagnetic radiation

Mesh:

Substances:

Year:  2020        PMID: 33146629     DOI: 10.1515/jbcpp-2020-0047

Source DB:  PubMed          Journal:  J Basic Clin Physiol Pharmacol        ISSN: 0792-6855


  1 in total

1.  The Preliminary Chronic Effects of Electromagnetic Radiation from Mobile Phones on Heart Rate Variability, Cardiac Function, Blood Profiles, and Semen Quality in Healthy Dogs.

Authors:  Van Nhut Khanh Dong; Lalida Tantisuwat; Piyathip Setthawong; Theerawat Tharasanit; Saikaew Sutayatram; Anusak Kijtawornrat
Journal:  Vet Sci       Date:  2022-04-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.