| Literature DB >> 33138977 |
Rachel E Culbreth1, Douglas S Gardenhire2.
Abstract
BACKGROUND: High peak pressures delivered via bag valve mask (BVM) can be dangerous for patients.Entities:
Keywords: Manual ventilation; Peak pressures; Respiratory therapists; Tidal volume
Year: 2020 PMID: 33138977 PMCID: PMC7604178 DOI: 10.1016/j.hrtlng.2020.10.012
Source DB: PubMed Journal: Heart Lung ISSN: 0147-9563 Impact factor: 2.210
Summary of manual ventilation performance among respiratory therapists by years of experience (n=98)
| Experience | Total | |||||
|---|---|---|---|---|---|---|
| 0-5 years | 6-10 years | 11-20 years | 21+ years | F-value or Fisher, p-value | 98 (100%) | |
| Mean Tidal Volume (ml) | 586.21 | 553.04 | 621.64 | 619.35 | 599.70 | |
| Flow Rate (l/min) | 76.43 | 73.16 | 76.95 | 79.31 | 77.20 | |
| Pressure (cmH2O) | 26.12 | 25.03 | 26.53 | 26.94 | 26.35 | |
| Inspiratory Time (sec) | 0.71 | 0.75 | 0.81 | 0.75 | 0.75 | |
| Rise Time (sec) | 0.47 | 0.52 | 0.54 | 0.47 | 0.49 | |
| Sex | ||||||
| Frequency of BVM use | ||||||
Summary of manual ventilation performance among the most experienced and most confident respiratory therapists (n=98)
| No. of providers (n) | Volume (ml) | No. of providers who delivered >600 ml | Pressure (cmH2O) | No. of providers who delivered >20 cmH2O | Flow (l/min) | Inspiratory time (sec) | Inspiratory Rise time (sec) | |
|---|---|---|---|---|---|---|---|---|
| All | 98 | 599.70 | 41 (41.8%) | 26.35 | 69 (70.4%) | 77.20 | 0.75 | 0.49 |
| Experience >10 Years | 54 (55.1%) | 619.90 | 27 (50.0%) | 26.84 | 35 (64.8%) | 78.74 | 0.76 | 0.48 |
| Self-Rated Confidence 5/5 | 49 (50.0%) | 616.22 | 24 (49.0%) | 29.80 | 39 (79.6%) | 84.01 | 0.71 | 0.47 |
| Experience >10 years and Self-Rated Confidence 5/5 | 28 (28.6%) | 631.43 | 15 (53.6%) | 30.55 | 20 (71.4%) | 86.10 | 0.71 | 0.46 |
Associated predictors of bag valve mask administered tidal volume among respiratory therapist participants (n=98)
| Variable | Estimate | Standard Error | P-value |
|---|---|---|---|
| Intercept | 489.36 | 56.07 | |
| Sex | 8.08 | 22.25 | 0.71 |
| Years of Experience | 1.40 | 0.74 | 0.06 |
| Frequency of BVM Use | 6.99 | 10.82 | 0.52 |
| Confidence | 17.62 | 11.77 | 0.14 |
Associated predictors of bag valve mask administered pressure among respiratory therapist participants (n=98)
| Variable | Estimate | Standard Error | P-value |
|---|---|---|---|
| Intercept | 15.02 | 6.03 | |
| Sex | -2.77 | 2.39 | 0.25 |
| Years of experience | -0.02 | 0.08 | 0.78 |
| Frequency of BVM Use | -0.78 | 1.16 | 0.50 |
| Confidence | 3.31 | 1.26 |
Associated predictors of bag valve mask administered flow rate among respiratory therapist participants, (n=98)
| Variable | Estimate | Standard Error | P-value |
|---|---|---|---|
| Intercept | 52.48 | 11.89 | |
| Sex | -4.97 | 4.72 | 0.29 |
| Years of experience | -0.002 | 0.16 | 0.99 |
| Frequency of BVM Use | -1.10 | 2.30 | 0.63 |
| Confidence | 6.75 | 2.50 |