| Literature DB >> 33137911 |
Yang Hu1, Diane J Cook1, Matthew E Taylor1,2,3.
Abstract
Smart-Home in a Box (SHiB) is a ubiquitous system that intends to improve older adults' life quality. SHiB requires self-installation before use. Our previous study found that it is not easy for seniors to install SHiB correctly. SHiB CBLE is a computer-based learning environment that is designed to help individuals install a SHiB kit. This article presents an experiment examining how smart home sensor installation was affected by knowledge gained from two methods, SHiB CBLE, and a written document. Results show that participants who were trained by the CBLE took significantly (p<0.05) less time in the installation session than those in the control group. The accuracy rate of SHiB kit installation is 78% for the group trained by the CBLE and 77% for the control group. Participants trained by the CBLE showed significantly (p<0.01) higher confidence in the actual installation than those in the control group. These results suggest that having a training before the actual installation will help installers avoid unnecessary work, shorten the installation time, and increase installers' confidence.Entities:
Keywords: online tutoring system; prior knowledge; smart home kit installation
Mesh:
Year: 2020 PMID: 33137911 PMCID: PMC7663102 DOI: 10.3390/s20216145
Source DB: PubMed Journal: Sensors (Basel) ISSN: 1424-8220 Impact factor: 3.576
Figure 1An example of a correct sensor placement for an apartment layout.
Figure 2An example of SHiB CBLE user interface.
Figure 3Worked examples in the control group’s instruction booklet.
Figure 4An example of hints for a room sensor.
Figure 5An example of hints for a kitchen sensor.
Figure 6An example of hints for a relay
Figure 7An example of hint for the server.
Figure 8Examples of post-tests.
Figure 9An example of evaluating an installation.
Post-survey questions.
| Index | Question Content | |
|---|---|---|
| 1 | How easy was it to install the sensors? | |
| 2 | How easy was it to install the names and terms for items? | |
| 3 | How easy was it to install the server box? | |
| 4 | How easy was it to follow the instruction manual? | |
| 5 | How easy would it be for other people to install the sensors and server box? | |
| 6 | Overall, how easy was the entire installation process? | |
| 7 | How easy was it to follow the installation tutorial software? | |
| 8 | Would you say that the installation process was long? | |
| 9 | Would you say that you were frustrated or anxious while installing the sensors? | |
| 10 | Would you say that the installation tutorial software was helpful for the actual installation? | |
| 11 | Would you recommend installing a Smart Home in a Box to others? | |
| 12 | Did you receive any help with installing the sensors? | |
| 13 | What aspects of the installation tutorial software did you find most useful? |
Results of real installation.
| Motion | Area | Temperature | Relay | Door | Server | Average Accuracy | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Total | Failure | Total | Failure | Total | Failure | Total | Failure | Total | Failure | Total | Failure | Rate % | |
| Experimental | 140 | 27 | 50 | 10 | 20 | 10 | 20 | 2 | 10 | 2 | 10 | 4 | |
| Accuracy | 80.7% | 80.0% | 50.0% | 90.0% | 80.0% | 60.0% | 78.0% | ||||||
| Control | 140 | 32 | 50 | 12 | 20 | 9 | 20 | 1 | 10 | 1 | 10 | 1 | |
| Accuracy | 77.1% | 76.0% | 55.0% | 95.0% | 90.0% | 90.0% | 77.6% | ||||||
Figure 10Sensor installation accuracy comparison.
Comparison of time spent in installation.
| Control Group | Experimental Group | ||
|---|---|---|---|
| Label No. | Installation (min) | Label No. | Installation (min) |
| 2 | 105 | 1 | 73 |
| 3 | 101 | 4 | 56 |
| 5 | 70 | 6 | 84 |
| 8 | 55 | 7 | 58 |
| 9 | 76 | 10 | 75 |
| 12 | 79 | 11 | 67 |
| 13 | 108 | 14 | 61 |
| 15 | 90 | 16 | 40 |
| 17 | 67 | 19 | 61 |
| 18 | 55 | 20 | 67 |
| mean(*) | 80.6 | 64.2 | |
| min | 55 | 40 | |
| max | 108 | 84 | |
| std | 18.7 | 11.5 | |
.
Results of post-survey of questions 1–6.
| Experimental Gorup | Control Gorup | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Participant No. | Q1 | Q2 | Q3 | Q4 | Q5 | Q6 | Participant No. | Q1 | Q2 | Q3 | Q4 | Q5 | Q6 |
| 1 | 2 | 4 | 4 | 4 | 4 | 3 | 2 | 4 | N/A | N/A | 4 | 4 | 4 |
| 4 | 4 | 4 | 4 | 4 | 4 | 4 | 3 | 3 | 4 | 3 | 4 | 3 | 4 |
| 6 | 4 | 4 | 5 | 4 | 4 | 4 | 5 | 4 | 5 | 4 | 4 | 4 | 4 |
| 7 | 4 | 4 | 5 | 4 | 4 | 4 | 8 | 4 | 4 | 4 | 4 | 4 | 4 |
| 10 | 5 | 4 | 3 | 4 | 4 | 4 | 9 | 4 | 4 | 3 | 4 | 4 | 4 |
| 11 | 5 | 5 | 5 | 5 | 5 | 5 | 12 | 4 | 4 | 5 | 4 | 3 | 4 |
| 14 | 5 | 5 | 5 | 5 | 3 | 4 | 13 | 5 | 5 | 5 | 5 | 5 | 3 |
| 16 | 3 | 5 | 4 | 4 | 4 | 3 | 15 | 3 | 4 | 5 | 4 | N/A | 4 |
| 19 | 5 | 4 | 5 | 5 | 5 | 5 | 17 | 3 | 3 | 4 | 3 | 3 | 3 |
| 20 | 4 | 5 | 5 | 4 | 4 | 4 | 18 | 4 | 3 | 4 | 3 | 3 | 4 |
| Average(**) | 4.1 | 4.4 | 4.5 | 4.3 | 4.1 | 4.0 | 3.8 | 4.0 | 4.1 | 3.9 | 3.7 | 3.8 | |
.
Post-survey results comparison on questions 7–10.
| Experimental group | Control group | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Participant No. | Q7 | Q8 | Q9 | Q10 | Participant No. | Q7 | Q8 | Q9 | Q10 |
| 1 | 4 | 5 | 4 | 5 | 2 | N/A | 2 | 2 | 4 |
| 4 | 4 | 5 | 2 | 5 | 3 | 4 | 3 | 2 | N/A |
| 6 | 4 | 3 | 2 | 4 | 5 | N/A | 2 | 2 | N/A |
| 7 | 4 | 4 | 3 | 5 | 8 | 4 | 3 | 1 | 1 |
| 10 | 3 | 3 | 2 | 3 | 9 | N/A | 3 | 3 | N/A |
| 11 | 4 | 2 | 1 | 3 | 12 | N/A | 4 | 2 | 4 |
| 14 | 4 | 2 | 2 | 2 | 13 | N/A | 3 | 3 | N/A |
| 16 | 4 | 3 | 3 | 4 | 15 | 3 | 5 | 4 | 3 |
| 19 | 3 | 2 | 2 | 4 | 17 | 4 | 3 | 4 | 4 |
| 20 | 3 | 4 | 2 | 4 | 18 | 5 | 3 | 2 | N/A |
| Average | 3.7 | 3.3 | 2.3 | 3.9 | 4.0 | 3.1 | 2.5 | 3.2 | |
Responses to Q13 of the experimental group and the control group.
| Experimental Group | Control Group | ||
|---|---|---|---|
| Participant No. | Response on Q13 | Participant No. | Response on Q13 |
| 1 | instructing every time and showing proper directions to set up the sensors | 2 | confused with relays |
| 4 | It help me understand where the ’area’ sensor should be placed | 3 | like enforce best places for sensors |
| 6 | place sensors and relays in the specific area | 5 | textbook is helpful for area sensors |
| 7 | the similarity between the software and manual instructions | 8 | textbook gives a general understanding of different sensor locations |
| 10 | knowing the placement of the sensors | 9 | N/A |
| 11 | locations of sensors | 12 | Floor plans with pictures is okay |
| 14 | Material is enough | 13 | N/A |
| 16 | practice, different steps | 15 | The figures showing positions of sensors might help |
| 19 | The visual displays translated over to the actual installation | 17 | all |
| 20 | going through the process of placing the items, the descriptions of how and where to place the items | 18 | The map (textbook) is useful |