Literature DB >> 33136935

The Performance of a 2-Dimensional Shear-Wave Elastography Technique for Predicting Different Stages of Liver Fibrosis Using Transient Elastography as the Control Method.

Felix Bende1, Ioan Sporea, Roxana Şirli, Silviu Nistorescu, Renata Fofiu, Victor Bâldea, Alina Popescu.   

Abstract

ABSTRACT: The aim was to evaluate the performance of 2-dimensional (2D) shear-wave elastography from general electric (2D SWE-GE), implemented on the new LOGIQ S8 system, for the noninvasive assessment of liver fibrosis, and to identify liver stiffness (LS) cutoff values for predicting different stages of fibrosis using transient elastography (TE) as the control method. We included 179 consecutive subjects, with or without chronic hepatopathies, in whom LS was evaluated in the same session using 2 elastographic techniques: TE (FibroScan, EchoSens) and 2D SWE-GE (LOGIQ S8; GE Healthcare, Chalfont St Giles, United Kingdom). Reliable LS measurements were defined for TE: the median value of 10 measurements with a success rate of 60% or greater and an interquartile range/median ratio (IQR/M) < 0.30; for 2D SWE-GE: the median value of 10 measurements acquired in a homogenous area and IQR/M < 0.30. To discriminate between fibrosis stages by TE, we used the following cutoffs: F2-7; F3-9.5 and F4-12 kPa. Reliable LS measurements were obtained in 97.2% subjects by 2D SWE-GE and in 98.3% by TE (P = 0.72), so that 171 subjects were included for the final analysis. A good correlation was found between the LS values obtained by the 2 methods (r = 0.72, P < 0.0001). The best 2D SWE-GE cutoff value for F ≥ 2 was 6.9 kPa (areas under receiver operating characteristic [AUROC], 0.93; sensitivity, 85.8%; specificity, 90.2%), for F of 3 or greater, it was 8.2 kPa (AUROC, 0.93; sensitivity, 87.5%; specificity, 86.8%) and for F value of 4, it was 9.3 kPa (AUROC, 0.91; sensitivity, 85.7%; specificity, 81.2%). In conclusion, the best 2D SWE-GE (S8) cutoff values for predicting F2, F ≥ 3 and F = 4 were 6.9, 8.2, and 9.3 kPa.
Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 33136935     DOI: 10.1097/RUQ.0000000000000527

Source DB:  PubMed          Journal:  Ultrasound Q        ISSN: 0894-8771            Impact factor:   1.657


  3 in total

1.  Quantification of Liver Fibrosis, Steatosis, and Viscosity Using Multiparametric Ultrasound in Patients with Non-Alcoholic Liver Disease: A "Real-Life" Cohort Study.

Authors:  Alexandru Popa; Felix Bende; Roxana Șirli; Alina Popescu; Victor Bâldea; Raluca Lupușoru; Radu Cotrău; Renata Fofiu; Camelia Foncea; Ioan Sporea
Journal:  Diagnostics (Basel)       Date:  2021-04-26

2.  Evaluation of liver fibrosis in chronic hepatitis B patients with 2D shear wave elastography with propagation map guidance: a single-centre study.

Authors:  Seyhmus Kavak; Safak Kaya; Ayhan Senol; Nilgun Sogutcu
Journal:  BMC Med Imaging       Date:  2022-03-18       Impact factor: 1.930

3.  Detection of liver and spleen stiffness in rats with portal hypertension by two-dimensional shear wave elastography.

Authors:  YongJian Chen; JingYun Li; Qin Zhou; GuoRong Lyu; ShiLin Li
Journal:  BMC Med Imaging       Date:  2022-04-13       Impact factor: 1.930

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.