Literature DB >> 33131888

Aorta size mismatch predicts decreased exercise capacity in patients with successfully repaired coarctation of the aorta.

Jason G Mandell1, Yue-Hin Loke2, Paige N Mass3, Justin Opfermann3, Vincent Cleveland3, Seda Aslan4, Narutoshi Hibino5, Axel Krieger4, Laura J Olivieri6.   

Abstract

OBJECTIVE: Coarctation of the aorta (CoA) is associated with decreased exercise capacity despite successful repair with no residual stenosis; however, the hemodynamic mechanism remains unknown. This study aims to correlate aortic arch geometry with exercise capacity in patients with successfully repaired CoA and explain hemodynamic changes using 3-dimensional-printed aorta models in a mock circulatory flow loop.
METHODS: A retrospective chart review identified patients with CoA repair who had cardiac magnetic resonance imaging and an exercise stress test. Measurements included aorta diameters, arch height to diameter ratio, left ventricular function, and percent descending aorta (%DAo) flow. Each aorta was printed 3-dimensionally for the flow loop. Flow and pressure were measured at the ascending aorta (AAo) and DAo during simulated rest and exercise. Measurements were correlated with percent predicted peak oxygen consumption (VO2 max).
RESULTS: Fifteen patients (mean age 26.8 ± 8.6 years) had a VO2 max between 47% and 126% predicted (mean 92 ± 20%) with normal left ventricular function. DAo diameter and %DAo flow positively correlated with VO2 (P = .007 and P = .04, respectively). AAo to DAo diameter ratio (DAAo/DDAo) negatively correlated with VO2 (P < .001). From flow loop simulations, the ratio of %DAo flow in exercise to rest negatively correlated with VO2 (P = .02) and positively correlated with DAAo/DDAo (P < .01).
CONCLUSIONS: This study suggests aorta size mismatch (DAAo/DDAo) is a novel, clinically important measurement predicting exercise capacity in patients with successful CoA repair, likely due to increased resistance and altered flow distribution. Aorta size mismatch and %DAo flow are targets for further clinical evaluation in repaired CoA.
Copyright © 2020 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cardiac magnetic resonance; coarctation of the aorta; exercise; mock circulatory flow loop

Mesh:

Year:  2020        PMID: 33131888     DOI: 10.1016/j.jtcvs.2020.09.103

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  2 in total

1.  Right ventricular afterload in repaired D-TGA is associated with inefficient flow patterns, rather than stenosis alone.

Authors:  Marc Delaney; Vincent Cleveland; Paige Mass; Francesco Capuano; Jason G Mandell; Yue-Hin Loke; Laura Olivieri
Journal:  Int J Cardiovasc Imaging       Date:  2021-11-02       Impact factor: 2.357

Review 2.  Hypertension after coarctation repair-a systematic review.

Authors:  Joseph Panzer; Thierry Bové; Kristof Vandekerckhove; Daniël De Wolf
Journal:  Transl Pediatr       Date:  2022-02
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.