Literature DB >> 33130221

The optimization of process analytical technology for the inline quantification of multiple drugs in fixed dose combinations during continuous processing.

Suha M Dadou1, Yiwei Tian2, Shu Li1, David S Jones2, Gavin P Andrews3.   

Abstract

Complications associated with uncontrolled hypertension are considered the major cause of premature death worldwide. Fixed-dose combinations (FDCs) offer an alternative approach to polypharmacy with the aim to improve patient compliance. Process Analytical Technology (PAT) is gaining momentum as a non-invasive, predictive tool to control the quality of drugs during continuous processing. PAT offers real-time quality control that can be built into the production line. However, the vast majority of studies reported in the literature have focused on quantifying a single drug during continuous processing. The aim of this study was to develop non-destructive, predictive inline PAT tools allowing for the simultaneous quantification of two antihypertensive drugs, Hydrochlorothiazide (HCTZ) and Ramipril (RMP), during the continuous manufacture of FDCs. A calibration set composed of HCTZ and RMP at concentration ranges of 6.5 to 40 and 2.5-15 (% w/w), respectively, were manufactured using hot melt extrusion. The extrudates were analysed during the process using inline Raman spectroscopy. Optimum wavenumber regions were observed at 200-400 and 630-730 cm-1 for HCTZ, and 980-1100 cm-1 for RMP using principal component analysis. Partial least squares (PLS) regression was performed to establish the predictive calibration models. The PLS developed models showed excellent linearity (R2 = 0.986 and 0.974), selectivity (PC1 = 98.6% and 91.9%) and accuracy (RMSEcv = 1.586 and 0.645%) for HCTZ and RMP, respectively. Additionally, RMSEP values were reported as 1.237 and 1.007% for HCTZ and RMP, respectively, depicting good predictability for drug content in the validation set. The output of this study demonstrated that utilisation of the full potential of chemometrics, Raman spectroscopy can be used for the simultaneous inline quantification of multiple drugs in complex formulations. This facilitates the in-process quality control of FDCs and other multicomponent systems during continuous pharmaceutical production.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Continuous manufacturing; Fixed dose combination; Hot melt extrusion; Inline Raman spectroscopy; Process analytical technology

Mesh:

Substances:

Year:  2020        PMID: 33130221     DOI: 10.1016/j.ijpharm.2020.120024

Source DB:  PubMed          Journal:  Int J Pharm        ISSN: 0378-5173            Impact factor:   5.875


  2 in total

1.  NIR-Based Intelligent Sensing of Product Yield Stress for High-Value Bioresorbable Polymer Processing.

Authors:  Konrad Mulrennan; Nimra Munir; Leo Creedon; John Donovan; John G Lyons; Marion McAfee
Journal:  Sensors (Basel)       Date:  2022-04-07       Impact factor: 3.576

Review 2.  Vibrational Spectroscopy in Assessment of Early Osteoarthritis-A Narrative Review.

Authors:  Chen Yu; Bing Zhao; Yan Li; Hengchang Zang; Lian Li
Journal:  Int J Mol Sci       Date:  2021-05-15       Impact factor: 5.923

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.