Literature DB >> 33129977

The anatomical reliability of the superficial circumflex iliac artery perforator (SCIP) flap.

Cédric Zubler1, David Haberthür2, Ruslan Hlushchuk2, Valentin Djonov2, Mihai A Constantinescu3, Radu Olariu4.   

Abstract

INTRODUCTION: In order to achieve a satisfactory functional and aesthetic result a thin skin flap is often required in surgical reconstruction of various body regions. Perforator flaps based on either the superficial or deep branch of the superficial circumflex iliac artery (SCIA) have been used for this purpose mainly in the Asian population. Recently the superficial plane has been established as a new way of elevating the flap. Anatomical studies and details of this new flap are lacking.
MATERIAL AND METHODS: Wide areas were harvested subfascially from the groin of Thiel-fixated cadavers. Both deep and superficial branches of the superficial circumflex iliac artery were carefully dissected and individually injected with μAngiofil. After CT-imaging the flaps were raised on the superficial plane, perforators were marked and the flaps subsequently rescanned. High-resolution images of regions of interest were taken using micro-CT.
RESULTS: A total of 21 flaps were harvested and analyzed. Both the deep and superficial branch provided more than three perforators per branch, however, the deep branch based flap was significantly larger (202 vs. 112 cm2, p < 0.01) and had a longer pedicle (9.1 vs. 6.6 cm, p < 0.01). Raising the flap in the superficial plane reliably reduces bulk and increases homogeneity.
CONCLUSIONS: The SCIP flap appears to have a reliable vascular blood supply. The SCIA and its main branches and perforators have a consistent vascular pattern. The deep branch of the SCIA has the anatomic potential to be the preferred pedicle in case larger flaps with longer pedicles are necessary.
Copyright © 2020 The Author(s). Published by Elsevier GmbH.. All rights reserved.

Keywords:  Deep branch; Perforator flap; Reconstructive surgery; Superficial branch; Superficial circumflex iliac artery; Superficial circumflex iliac artery perforator flap

Year:  2020        PMID: 33129977     DOI: 10.1016/j.aanat.2020.151624

Source DB:  PubMed          Journal:  Ann Anat        ISSN: 0940-9602            Impact factor:   2.698


  1 in total

1.  Y-shaped Muscular Wrapping Technique Avoiding Re-infection of a Replaced Aortic Graft: A Cadaveric Study.

Authors:  Itaru Tsuge; Susumu Saito; Masako Kataoka; Hiroki Yamanaka; Motoki Katsube; Michiharu Sakamoto; Naoki Morimoto
Journal:  Plast Reconstr Surg Glob Open       Date:  2021-06-16
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.