Literature DB >> 33105362

Validity and Reliability of Methods to Determine Barbell Displacement in Heavy Back Squats: Implications for Velocity-Based Training.

Brendyn B Appleby1,2, Harry Banyard1,3, Stuart J Cormack4, Robert U Newton1,5.   

Abstract

Appleby, BB, Banyard, H, Cormack, SJ, and Newton, RU. Validity and reliability of methods to determine barbell displacement in heavy back squats: Implications for velocity-based training. J Strength Cond Res 34(11): 3118-3123, 2020-The purpose of this study was to investigate the validity and reliability of methods for determining barbell displacement during heavy back squats. Twelve well-trained rugby union players (mean ± SD 1 repetition maximum [1RM] 90° squat = 196.3 ± 29.2 kg) completed 2 sets of 2 repetitions at 70, 80, and 90% of 1RM squats. Barbell displacement was derived from 3 methods across 4 load categories (120-129, 140-149, 160-169, and 180-189 kg) including: a (a) linear position transducer (LPT) attached 65 cm left of barbell center, (b) 3D motion analysis tracking of markers attached to either end of a barbell, and (c) cervical marker (C7) (criterion measurement). Validity was calculated using the typical error of the estimate as a coefficient of variation (CV%) ±90% confidence interval (CI), mean bias as a percentage, and the Pearson product moment correlation (r). Intraday reliability was calculated using the intraclass correlation coefficient and the typical error expressed as a percentage of CV% ±90% (CI). Mean displacement for C7, LPT, and the barbell ends was 520, 529, and 550-564 mm, respectively. Validity of the LPT compared with the criterion was acceptable (CV% = 2.1-3.0; bias = 0.9-1.5%; r = 0.96-0.98), whereas that of the barbell ends was less (CV% = 2.7-7.5; bias = 4.9-11.2%; r = 0.71-0.97). The CV% reliability of the C7 marker across the load categories was 6.6%, the LPT 6.6%, and the barbell ends between 5.9 and 7.2%. Despite reliable measures, overestimation of displacement occurs as the tracking location moves to the barbell ends in weighted back squats. The LPT demonstrated high validity to the criterion and high trial-to-trial reliability.

Mesh:

Year:  2020        PMID: 33105362     DOI: 10.1519/JSC.0000000000002803

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  4 in total

1.  Reliability of technologies to measure the barbell velocity: Implications for monitoring resistance training.

Authors:  Alejandro Martínez-Cava; Alejandro Hernández-Belmonte; Javier Courel-Ibáñez; Ricardo Morán-Navarro; Juan José González-Badillo; Jesús G Pallarés
Journal:  PLoS One       Date:  2020-06-10       Impact factor: 3.240

2.  Velocity Loss Thresholds Reliably Control Kinetic and Kinematic Outputs during Free Weight Resistance Training.

Authors:  Madison Pearson; Amador García-Ramos; Matthew Morrison; Carlos Ramirez-Lopez; Nicholas Dalton-Barron; Jonathon Weakley
Journal:  Int J Environ Res Public Health       Date:  2020-09-07       Impact factor: 3.390

3.  Validation of Inertial Sensor to Measure Barbell Kinematics across a Spectrum of Loading Conditions.

Authors:  John C Abbott; John P Wagle; Kimitake Sato; Keith Painter; Thaddeus J Light; Michael H Stone
Journal:  Sports (Basel)       Date:  2020-06-29

4.  Validity and Reliability of the Inertial Measurement Unit for Barbell Velocity Assessments: A Systematic Review.

Authors:  Filipe Manuel Clemente; Zeki Akyildiz; José Pino-Ortega; Markel Rico-González
Journal:  Sensors (Basel)       Date:  2021-04-03       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.