Literature DB >> 33094416

Evaluation of the Whole Body Spine Response to Sub-Injurious Vertical Loading.

Kyle A Ott1, Constantine K Demetropoulos2, Mary E Luongo2, Jack M Titus3, Andrew C Merkle2, David G Drewry2.   

Abstract

It is critical to understand the relationship between under-body blast (UBB) loading and occupant response to provide optimal protection to the warfighter from serious injuries, many of which affect the spine. Previous studies have examined component and whole body response to accelerative based UBB loading. While these studies both informed injury prediction efforts and examined the shortcomings of traditional anthropomorphic test devices in the evaluation of human injury, few studies provide response data against which future models could be compared and evaluated. The current study examines four different loading conditions on a seated occupant that demonstrate the effects of changes in the floor, seat, personal protective equipment (PPE), and reclined posture on whole body post-mortem human surrogate (PMHS) spinal response in a sub-injurious loading range. Twelve PMHS were tested across floor velocities and time-to-peak (TTP) that ranged from 4.0 to 8.0 m/s and 2 to 5 ms, respectively. To focus on sub-injurious response, seat velocities were kept at 4.0 m/s and TTP ranged from 5 to 35 ms. Results demonstrated that spine response is sensitive to changes in TTP and the presence of PPE. However, spine response is largely insensitive to changes in floor loading. Data from these experiments have also served to develop response corridors that can be used to assess the performance and predictive capability of new test models used as human surrogates in high-rate vertical loading experiments.
© 2020. Biomedical Engineering Society.

Entities:  

Keywords:  Biomechanics; Injury; PMHS; Response corridors; Spine; Underbody blast; Vertical loading

Mesh:

Year:  2020        PMID: 33094416     DOI: 10.1007/s10439-020-02656-0

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  4 in total

1.  Biomechanics of human thoracolumbar spinal column trauma from vertical impact loading.

Authors:  Narayan Yoganandan; Mike W J Arun; Brian D Stemper; Frank A Pintar; Dennis J Maiman
Journal:  Ann Adv Automot Med       Date:  2013

2.  The use of acoustic emission in facial fracture detection.

Authors:  Joseph Cormier; Sarah Manoogian; Jill Bisplinghoff; Craig McNally; Stefan Duma
Journal:  Biomed Sci Instrum       Date:  2008

3.  Evaluation of WIAMan Technology Demonstrator Biofidelity Relative to Sub-Injurious PMHS Response in Simulated Under-body Blast Events.

Authors:  Hollie A Pietsch; Kelly E Bosch; David R Weyland; E Meade Spratley; Kyvory A Henderson; Robert S Salzar; Terrance A Smith; Brandon M Sagara; Constantine K Demetropoulos; Christopher J Dooley; Andrew C Merkle
Journal:  Stapp Car Crash J       Date:  2016-11

4.  Comparison of Human Surrogate Responses in Underbody Blast Loading Conditions.

Authors:  K Ott; D Drewry; M Luongo; J Andrist; R Armiger; J Titus; C Demetropoulos
Journal:  J Biomech Eng       Date:  2020-09-01       Impact factor: 2.097

  4 in total
  2 in total

1.  Verification of High-Rate Vertical Loading Laboratory Skeletal Fractures by Comparison with Theater Injury Patterns.

Authors:  K A Danelson; J G Polich; D R Barnes; G S Bullock; A T Scott; J J Halvorson; T O'Gara; H T Pilson; S Babcock; J Birkedal; B McAllister; K L Loftis
Journal:  Ann Biomed Eng       Date:  2021-10-15       Impact factor: 3.934

2.  Whole Body PMHS Response in Injurious Experimental Accelerative Loading Events.

Authors:  Jonathan D Rupp; Lauren Zaseck; Carl S Miller; Anne C Bonifas; Matthew P Reed; Don Sherman; John M Cavanaugh; Kyle Ott; Constantine K Demetropoulos
Journal:  Ann Biomed Eng       Date:  2021-06-17       Impact factor: 3.934

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.