Tine-Based Leadless Pacemaker: Strategies for Safe Implantation in Unconventional Clinical Scenarios.

Toshimasa Okabe1, Muhammad R Afzal2, Mahmoud Houmsse2, Mina S Makary3, Eric D Elliot3, Emile G Daoud2, Ralph S Augostini2, John D Hummel2.   

Abstract

Leadless pacemakers (LPs) have emerged as a meaningful alternative to transvenous pacemakers for single-ventricular pacing. LPs eliminate many of lead- and pocket-associated complications observed with transvenous pacemakers. Owing to the lack of atrioventricular synchronous pacing until recently, the use of LP was generally reserved for those patients who either required minimal ventricular pacing or had permanent atrial fibrillation. The only commercially available LP is the Micra transcatheter pacing system (Micra-TPS, Medtronic Inc. Fridley, Minnesota), which requires insertion of a 27-F (outer diameter) introducer sheath in the femoral vein. The LP is delivered to the right ventricle using a 23-F delivery catheter. Owing to the need for a large-bore sheath, the pivotal studies for the Micra transcatheter pacing system excluded patients with indwelling inferior vena cava filters and included only a few patients with bioprosthetic or repaired tricuspid valve. Subsequent real-world experience has demonstrated the overall safety and feasibility of LP placement, and use in various unconventional clinical settings has been validated, albeit with specific precautions. Additionally, incorporation of adjunctive techniques and strategies can improve the safety of the procedure in routine clinical settings as well. The objective of this state-of-the-art review is to highlight the key procedural elements to facilitate safe and efficient implantation of LP in routine as well as in unique clinical settings.
Copyright © 2020 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cardiac tamponade; hemostasis; inferior vena cava; leadless pacemaker; tricuspid valve surgery

Mesh:

Year:  2020        PMID: 33092762     DOI: 10.1016/j.jacep.2020.08.021

Source DB:  PubMed          Journal:  JACC Clin Electrophysiol        ISSN: 2405-500X


  2 in total

1.  Leadless pacemaker implantation in a subpulmonic left ventricle in a patient with congenitally corrected transposition of the great arteries.

Authors:  Ravi S Shah; William R Davidson; Soraya M Samii
Journal:  HeartRhythm Case Rep       Date:  2022-03-23

2.  Leadless pacemaker implantation with hybrid image mapping technique in a congenital heart disease case.

Authors:  Jose Luis Martinez-Sande; Laila Gonzalez-Melchor; Javier Garcia-Seara; Moises Rodriguez-Mañero; Xesus Alberte Fernandez-Lopez; Jose Ramon Gonzalez Juanatey
Journal:  HeartRhythm Case Rep       Date:  2021-07-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.