Retrospective Review of Preoperative Radiofrequency Tag Localization of Breast Lesions in 848 Patients.

Leslie R Lamb1, Luke Gilman1, Michelle Specht2, Helen Anne D'Alessandro1, Randy C Miles1, Constance D Lehman1.   

Abstract

BACKGROUND. Advantages of radiofrequency tags for preoperative breast lesion localization include decoupling of tag placement from surgical schedules and improved patient comfort. OBJECTIVE. The purpose of this study was to evaluate the feasibility of a preoperative localization radiofrequency tag system for breast lesions requiring surgical excision. METHODS. The cohort for this retrospective study included consecutive patients who underwent image-guided needle localization with radiofrequency tags before surgical excision from July 12, 2018, to July 31, 2019. Images and medical records were reviewed to evaluate the pathologic diagnoses serving as indications for tag placement, imaging guidance for tag placement, number of tags placed, and target lesion type. Tag placement technical accuracy rate (defined as deployment of the tag within 1 cm of the edge of the target), success (defined as technical accuracy without complication), and surgical margin and reexcision status were evaluated. RESULTS. A total of 1013 tags were placed under imaging guidance in 848 patients (mean age, 60 years; range, 23-96 years) and 847 subsequently underwent surgical excision. Tags were most commonly placed for invasive carcinoma (537/1013, 53.0%), ductal carcinoma in situ (138/1013, 13.6%), and high-risk lesions (289/1013, 28.5%). A total of 673 (66.4%) tags were deployed under mammographic guidance, whereas 340 (33.6%) were placed under sonographic guidance. Two or more tags were placed in 149 of 848 patients (17.6%). Targeted lesion types primarily included masses (448/1013, 44.2%), biopsy clip markers (331/1013, 32.7%), and calcifications (155/1013, 15.3%). Technical accuracy of placement was achieved in 1004 (99.1%) tags. Of the nine inaccurate tag placements, seven (77.8%) required an additional tag or wire placement. Seven (0.7%) biopsy clip markers were displaced within the breast or removed by the tag device during placement. No complications were reported intraoperatively. Therefore, success was achieved in 997 (98.4%) tags. Tags were successfully retrieved in all 847 patients who underwent surgery. Of the 568 patients with a preoperative diagnosis of carcinoma, 86 (15.1%) had positive or close surgical margins requiring surgical reexcision. CONCLUSION. Preoperative image-guided localization with radiofrequency tags is a safe and feasible technique for breast lesions requiring surgery. CLINICAL IMPACT. Radiofrequency tag localization is an acceptable alternative to needle or wire localization, offering the potential for improved patient workflow and experience.

Entities:  

Keywords:  breast cancer; image-guided intervention; nonradioactive; wireless localization

Year:  2021        PMID: 33084384     DOI: 10.2214/AJR.20.24374

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  1 in total

1.  Radio-Frequency Identifier Devices (RFIDs): Our Experience With Wireless Localisation in Non-palpable Breast Masses at a UK Tertiary Breast Imaging Unit.

Authors:  Chitrangada Singh; Arne Juette
Journal:  Cureus       Date:  2022-02-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.