Literature DB >> 33083888

3D Echocardiography Provides Highly Accurate 3D Printed Models in Congenital Heart Disease.

K L Mowers1, J B Fullerton2, D Hicks1, G K Singh1, M C Johnson1, S Anwar3.   

Abstract

Cardiac 3D printing is mainly performed from magnetic resonance imaging (MRI) and computed tomography (CT) 3D datasets, though anatomic detail of atrioventricular (AV) valves may be limited. 3D echo provides excellent visualization of AV valves. Thus, we tested the feasibility and accuracy of 3D printing from 3D echo in this pilot series of subjects with congenital heart disease (CHD), with a focus on valve anatomy. Five subjects with CHD were identified. 3D echo data were converted to 3D printable files and printed in collaboration with 3D Systems Healthcare (Golden, Colorado). A novel technique for valve modeling was utilized using commercially available software. Two readers (KM, SA) independently measured valve structures from 3D models and compared to source echo images. 3D printing was feasible for all cases. Table 1 shows measurements comparing 2D echo to 3D models. Bland Altman analysis showed close agreement and no significant bias between 2D and digital 3D models (mean difference 0.0, 95% CI 1.1 to - 1.1) or 2D vs printed 3D models, though with wider limits of agreement (mean difference - 0.3, 95% CI 1.9 to - 2.6). Accuracy of 3D models compared to 2D was within < 0.5 mm. This pilot study shows 3D echo datasets can be used to reliably print AV and semilunar valve structures in CHD. The 3D models are highly accurate compared to the source echo images. This is a novel and value-added technique that adds incremental information on cardiac anatomy over current methods.

Entities:  

Keywords:  3D echocardiography; 3D printing; Accuracy; Congenital heart disease; Valves

Mesh:

Year:  2020        PMID: 33083888     DOI: 10.1007/s00246-020-02462-4

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  1 in total

1.  Echocardiography derived three- dimensional printing of normal and abnormal mitral annuli.

Authors:  K K Kapur; Naveen Garg
Journal:  Ann Card Anaesth       Date:  2014 Oct-Dec
  1 in total
  3 in total

Review 1.  Organization of Pediatric Echocardiography Laboratories: Impact of Sonographers on Clinical, Academic, and Financial Performance.

Authors:  Nick Arbic; Maelys Venet; Xavier Iriart; Andreea Dragulescu; Jean-Benoit Thambo; Mark K Friedberg; Vitor Guerra; Conall Thomas Morgan; Luc Mertens; Olivier Villemain
Journal:  Front Pediatr       Date:  2022-05-30       Impact factor: 3.569

2.  Quantitative Assessment of 3D Printed Model Accuracy in Delineating Congenital Heart Disease.

Authors:  Shenyuan Lee; Andrew Squelch; Zhonghua Sun
Journal:  Biomolecules       Date:  2021-02-12

Review 3.  3D Approaches in Complex CHD: Where Are We? Funny Printing and Beautiful Images, or a Useful Tool?

Authors:  Adriani Spanaki; Saleha Kabir; Natasha Stephenson; Milou P M van Poppel; Valentina Benetti; John Simpson
Journal:  J Cardiovasc Dev Dis       Date:  2022-08-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.