Literature DB >> 33081937

Ratiometric electrogenerated chemiluminescence sensor based on a designed anti-fouling peptide for the detection of carcinoembryonic antigen.

Qiuxia Hao1, Lei Wang1, Shuyan Niu1, Caifeng Ding2, Xiliang Luo1.   

Abstract

In this paper, an effective and accurate ratiometric electrochemiluminescence (ECL) system based on Au-luminol and CdS quantum dots (CdS QDs) as signal probes was constructed for detecting carcinoembryonic antigen (CEA). Polyaniline (PANI) and gold nanoparticles (AuNPs) strongly enhanced the electronic transfer efficiency and the specific area of the modified sensing surface, and improved the detection sensitivity. CdS QDs functionalized DNA strands functioned as cathode ECL emitters, and the aptamer of CEA modified with Au-luminol and quencher cyanine dye (Cy5) fluorophore functioned as anode ECL emitters. After the DNA capture probe combined with CEA aptamer, the negative potential ECL response of the CdS QDs was quenched because of electrochemiluminescence resonance energy transfer (ERET) between the Cy5 fluorophore and CdS QDs. However, the positive potential ECL response of Au-luminol can still be detected. The negative potential ECL response of CdS QDs was recovered, and the positive potential ECL response of Au-luminol decreased after CEA combined with its aptamer to take Cy5 and Au-luminol off the sensing interface. Additionally, the peptide provided effective anti-fouling performance in the detection of complex samples. The ratiometric ECL sensor with anti-fouling ability can sensitively determine the concentration of CEA in human serum.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Anti-fouling peptide; Au-luminol; Carcinoembryonic antigen; CdS QDs; Electrogenerated chemiluminescence (ECL); Ratiometric biosensor

Mesh:

Substances:

Year:  2020        PMID: 33081937     DOI: 10.1016/j.aca.2020.09.033

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Biocompatible graphene-zirconia nanocomposite as a cyto-safe immunosensor for the rapid detection of carcinoembryonic antigen.

Authors:  Lih Poh Lin; Shiau-Ying Tham; Hwei-San Loh; Michelle T T Tan
Journal:  Sci Rep       Date:  2021-11-18       Impact factor: 4.379

Review 2.  Recent advances and future prospects of the potential-resolved strategy in ratiometric, multiplex, and multicolor electrochemiluminescence analysis.

Authors:  Shijun Wang; Shu Zhu; Ziqi Kang; Yidan Chen; Xiancheng Liu; Zixin Deng; Kun Hu; Guixue Wang; Yuchan Zhang; Guangchao Zang
Journal:  Theranostics       Date:  2022-09-21       Impact factor: 11.600

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.