Literature DB >> 33080584

In vivoneutron activation assembly design for quantification of trace elements using MCNP.

Sana Tabbassum1, Linda H Nie1.   

Abstract

Background: Trace and essential elements both play a crucial role in maintaining normal cellular and organ functions in human, while abnormal exposure to some of them is also potentially related to diseases, e.g.manganism. To study the association between elemental intake and health outcomes, accurate assessment of elemental uptake and storage in the human body is essential.Objective: Technology based on neutron activation analysis can be used forin vivomeasurement of the trace elements given that the measurement system guarantees a low detection limit with an acceptable dose. This study aims to design and optimize a customized and portable deuterium-deuterium neutron generator-based irradiation assembly for the NAA of trace elementsin vivo,using Monte Carlo simulations.Approach: The irradiation assembly includes a moderator, a fast neutron filter, a reflector, and shielding. The human hand phantoms doped with manganese (Mn) and potassium (K) are used to determine the respective elements' system sensitivity and detection limit.Main results: The calculated detection limit is 0.16μg Mn per gram dry bone (ppm) for Mn and 17 ppm for K, with an equivalent dose of 36 mSv to the hand for 10 min irradiation.Significance: This more sensitivein vivoneutron activation analysis system will detect trace elementsin vivo.
© 2020 Institute of Physics and Engineering in Medicine.

Entities:  

Keywords:  Monte Carlo; in vivo; manganese; neutron generator; potassium

Mesh:

Substances:

Year:  2020        PMID: 33080584      PMCID: PMC8055719          DOI: 10.1088/1361-6579/abc322

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  13 in total

1.  NEUTRON-ACTIVATION ANALYSIS IN MAN IN VIVO. A NEW TECHNIQUE IN MEDICAL INVESTIGATION.

Authors:  J ANDERSON; S B OSBORN; R W TOMLINSON; D NEWTON; J RUNDO; L SALMON; J W SMITH
Journal:  Lancet       Date:  1964-12-05       Impact factor: 79.321

2.  A compact DD neutron generator-based NAA system to quantify manganese (Mn) in bone in vivo.

Authors:  Yingzi Liu; Patrick Byrne; Haoyu Wang; David Koltick; Wei Zheng; Linda H Nie
Journal:  Physiol Meas       Date:  2014-08-26       Impact factor: 2.833

3.  Introduction to neutron stimulated emission computed tomography.

Authors:  Carey E Floyd; Janelle E Bender; Amy C Sharma; Anuj Kapadia; Jessie Xia; Brian Harrawood; Georgia D Tourassi; Joseph Y Lo; Alexander Crowell; Calvin Howell
Journal:  Phys Med Biol       Date:  2006-06-26       Impact factor: 3.609

4.  Neutron stimulated emission computed tomography: a Monte Carlo simulation approach.

Authors:  A C Sharma; B P Harrawood; J E Bender; G D Tourassi; A J Kapadia
Journal:  Phys Med Biol       Date:  2007-10-01       Impact factor: 3.609

5.  Customized compact neutron activation analysis system to quantify manganese (Mn) in bone in vivo.

Authors:  Yingzi Liu; Farshad Mostafaei; Daniel Sowers; Mindy Hsieh; Wei Zheng; Linda H Nie
Journal:  Physiol Meas       Date:  2017-01-06       Impact factor: 2.833

6.  In vivo neutron activation analysis of bone manganese in workers.

Authors:  Yingzi Liu; Danelle Rolle-McFarland; Farshad Mostafaei; Yuanzhong Zhou; Yan Li; Wei Zheng; Ellen Wells; Linda H Nie
Journal:  Physiol Meas       Date:  2018-03-23       Impact factor: 2.833

7.  Quantification of manganese in human hand bones: a feasibility study.

Authors:  A Pejović-Milić; D R Chettle; F E McNeill
Journal:  Phys Med Biol       Date:  2008-08-07       Impact factor: 3.609

8.  A preliminary study for non-invasive quantification of manganese in human hand bones.

Authors:  A Pejović-Milić; D R Chettle; F E McNeill; M W Pysklywec; J Oudyk
Journal:  Phys Med Biol       Date:  2008-09-02       Impact factor: 3.609

9.  Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89.

Authors: 
Journal:  Ann ICRP       Date:  2002

10.  Opportunities to improve the in vivo measurement of manganese in human hands.

Authors:  D R Chettle; A Pejović-Milić; A J Waker
Journal:  Phys Med Biol       Date:  2008-12-05       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.