Literature DB >> 33079877

Arterial Catheters for Early Detection and Treatment of Hypotension During Major Noncardiac Surgery: A Randomized Trial.

Amanda J Naylor1, Daniel I Sessler1, Kamal Maheshwari1,2, Ashish K Khanna1,2, Dongsheng Yang1,3, Edward J Mascha1,3, Iman Suleiman1, Eric M Reville1, Devan Cote1, Matthew T Hutcherson1, Bianka M Nguyen1, Hesham Elsharkawy1,2, Andrea Kurz1,2.   

Abstract

BACKGROUND: Continuous blood pressure monitoring may facilitate early detection and prompt treatment of hypotension. We tested the hypothesis that area under the curve (AUC) mean arterial pressure (MAP) <65 mm Hg is reduced by continuous invasive arterial pressure monitoring.
METHODS: Adults having noncardiac surgery were randomly assigned to continuous invasive arterial pressure or intermittent oscillometric blood pressure monitoring. Arterial catheter pressures were recorded at 1-minute intervals; oscillometric pressures were typically recorded at 5-minute intervals. We estimated the arterial catheter effect on AUC-MAP <65 mm Hg using a multivariable proportional odds model adjusting for imbalanced baseline variables and duration of surgery. Pressures <65 mm Hg were categorized as 0, 1-17, 18-91, and >91 mm Hg × minutes of AUC-MAP <65 mm Hg (ie, no hypotension and 3 equally sized groups of increasing hypotension).
RESULTS: One hundred fifty-two patients were randomly assigned to arterial catheter use and 154 to oscillometric monitoring. For various clinical reasons, 143 patients received an arterial catheter, while 163 were monitored oscillometrically. There were a median [Q1, Q3] of 246 [187, 308] pressure measurements in patients with arterial catheters versus 55 (46, 75) measurements in patients monitored oscillometrically. In the primary intent-to-treat analysis, catheter-based monitoring increased detection of AUC-MAP <65 mm Hg, with an estimated proportional odds ratio (ie, odds of being in a worse hypotension category) of 1.78 (95% confidence interval [CI], 1.18-2.70; P = .006). The result was robust over an as-treated analysis and for sensitivity analyses with thresholds of 60 and 70 mm Hg.
CONCLUSIONS: Intraoperative blood pressure monitoring with arterial catheters detected nearly twice as much hypotension as oscillometric measurements.

Entities:  

Mesh:

Year:  2020        PMID: 33079877     DOI: 10.1213/ANE.0000000000004370

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  4 in total

1.  [Hot topics in anesthesiology 2019/2020].

Authors:  Marcus Thudium; Andreas Hoeft; Mark Coburn
Journal:  Anaesthesist       Date:  2021-01       Impact factor: 1.041

Review 2.  Intraoperative hypotension: Pathophysiology, clinical relevance, and therapeutic approaches.

Authors:  Karim Kouz; Phillip Hoppe; Luisa Briesenick; Bernd Saugel
Journal:  Indian J Anaesth       Date:  2020-02-04

Review 3.  Norepinephrine in Goal-Directed Fluid Therapy During General Anesthesia in Elderly Patients Undergoing Spinal Operation: Determining Effective Infusion Rate to Enhance Postoperative Functions.

Authors:  Fan Wu; Tao Liang; Wei Xiao; Tianlong Wang
Journal:  Curr Genomics       Date:  2021-12-31       Impact factor: 2.689

4.  Development and comparison of an esophageal Doppler monitoring-based treatment algorithm with a heart rate and blood pressure-based treatment algorithm for goal-directed fluid therapy in anesthetized dogs: A pilot study.

Authors:  Inken Sabine Henze; Laura Hilpert; Annette P N Kutter
Journal:  Front Vet Sci       Date:  2022-10-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.