Literature DB >> 33077369

Interradicular sites and cortical bone thickness for miniscrew insertion: A systematic review with meta-analysis.

Michele Tepedino1, Paolo M Cattaneo2, Xiaowen Niu3, Marie A Cornelis2.   

Abstract

INTRODUCTION: Safe zone maps are useful for the clinician to plan miniscrew insertion and possibly reduce radiation exposure. This study aimed to investigate the available evidence regarding the presence of sufficient interradicular space and adequate cortical bone thickness in patients with a complete permanent dentition, in the vestibular and palatal or lingual interradicular sites, mesial to the second molar.
METHODS: PubMed, Scopus, Web of Science, Cochrane Library, and OpenGrey databases were searched up to January 2019 for observational studies involving patients with fully erupted second molars that investigated the amount of interradicular space and/or the cortical thickness of the alveolar processes using 3-dimensional data sets. A custom tool was prepared and used to assess the risk of bias in individual studies. A meta-analysis was performed when at least 4 different studies evaluated 1 identical parameter homogeneously. Publication bias was assessed with the Egger linear regression test.
RESULTS: Twenty-seven observational articles were included in the qualitative synthesis. Only 11 articles were at low risk of bias. Fifteen articles were included in the meta-analysis. The results were graphically reported in "safe-zone" maps.
CONCLUSIONS: In the maxilla, the most suitable insertion sites are those from mesial to the first molar to distal to the first premolar, and between the canine and the lateral incisor, all at 6 mm from the cementoenamel junction. In those areas, the cortical bone has adequate thickness, not requiring predrilling. In the mandible, the preferable vestibular interradicular spaces are those between first and second molars and between first and second premolars, both at 5 mm from the cementoenamel junction, and predrilling is suggested in these areas. TRIAL REGISTRATION NUMBER: PROSPERO CRD42016042081.
Copyright © 2020 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2020        PMID: 33077369     DOI: 10.1016/j.ajodo.2020.05.011

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  2 in total

1.  Effect of Different Surface Designs on the Rotational Resistance and Stability of Orthodontic Miniscrews: A Three-Dimensional Finite Element Study.

Authors:  Jin-Young Choi; Jaehee Cho; Song Hee Oh; Seong-Hun Kim; Kyu-Rhim Chung; Gerald Nelson
Journal:  Sensors (Basel)       Date:  2021-03-11       Impact factor: 3.576

2.  Bone quality affects stability of orthodontic miniscrews.

Authors:  Wan-Ping Yu; Ming-Tzu Tsai; Jian-Hong Yu; Heng-Li Huang; Jui-Ting Hsu
Journal:  Sci Rep       Date:  2022-02-18       Impact factor: 4.379

  2 in total