Literature DB >> 33074867

Outcomes Following Left Ventricular Assist Device Exchange: Focus on the Impacts of Device Infection.

Gardner Yost1,2, Laura Coyle1, Colleen Gallagher1, William Cotts1, Patroklos Pappas1, Antone Tatooles1.   

Abstract

Hemodynamic support with continuous-flow left ventricular assist device (CF-LVAD) therapy has proven a reliable treatment for advanced heart failure. Although modern LVADs are highly durable, device failure and infection can be resolved with surgical exchange of pump components. In this study, we investigated the incidence and outcomes of LVAD exchange with the HeartMate II and HeartWare HVAD. Data were obtained from 677 patients who underwent CF-LVAD implantation between 2005 and 2016. Patients who underwent a device exchanged were included. The primary outcomes were length of hospital stay and mortality. Of the 677 patients included in this study, 72 (10.6%) required LVAD exchange. Thirty-day and 1-year mortality rates were comparable to primary LVAD implantation: 4.3% vs. 3.49%, p = 0.727 and 20.3% vs. 20.7%, p = 0.989, respectively. Thirty-one patients (4.5%) underwent exchange with ongoing infection. Kaplan-Meier analysis indicated significant differences in survival between groups based on indication for exchange. Patients who underwent exchange after more than 150 days of active infection suffered worse postexchange survival than those who underwent exchanged earlier (P = 0.007). While exchange was required only in 10.6% of patients undergoing LVAD implantation, our results show device exchange may be executed safely and effectively, with long-term outcomes similar to primary LVAD implantation. The indication for device exchange impacts postexchange outcomes, and those exchanged with LVAD infection tend to fare worse than those exchanged for device malfunction or thrombus. Patients who are exchanged with active infection have better postoperative survival if the exchange is performed expeditiously after medical management has failed.
Copyright © ASAIO 2020.

Entities:  

Year:  2021        PMID: 33074867     DOI: 10.1097/MAT.0000000000001287

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Association Between Care Fragmentation and Total Spending After Durable Left Ventricular Device Implant: A Mediation Analysis of Health Care-Associated Infections Within a National Medicare-Society of Thoracic Surgeons Intermacs Linked Dataset.

Authors:  K Dennie Kim; Russell J Funk; Hechuan Hou; Austin Airhart; Khalil Nassar; Francis D Pagani; Min Zhang; P Paul Chandanabhumma; Keith D Aaronson; Carol E Chenoweth; Ahmad Hider; Lourdes Cabrera; Donald S Likosky
Journal:  Circ Cardiovasc Qual Outcomes       Date:  2022-09-06

2.  Bacteriophage-Enriched Galenic for Intrapericardial Ventricular Assist Device Infection.

Authors:  Sebastian V Rojas; Simon Junghans; Henrik Fox; Kanstantsin Lazouski; Rene Schramm; Michiel Morshuis; Jan F Gummert; Justus Gross
Journal:  Antibiotics (Basel)       Date:  2022-04-29

Review 3.  Ventricular Assist Device-Specific Infections.

Authors:  Yue Qu; Anton Y Peleg; David McGiffin
Journal:  J Clin Med       Date:  2021-01-25       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.