Literature DB >> 33070378

Indoor air quality in new and renovated low-income apartments with mechanical ventilation and natural gas cooking in California.

Haoran Zhao1, Wanyu R Chan1, Sebastian Cohn2, William W Delp1, Iain S Walker1, Brett C Singer1.   

Abstract

This paper presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM2.5 ), nitrogen dioxide (NO2 ), formaldehyde and carbon dioxide (CO2 ) and time-integrated formaldehyde, NO2 and nitrogen oxides (NOX ). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM2.5 , formaldehyde, NO2 , and CO2 were 7.7 µg/m3 , 14.1, 18.8, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM2.5 above the California annual outdoor standard of 12 µg/m3 and also discrete days above the World Health Organization 24-hour guideline of 25 µg/m3 . Two apartments had weekly NO2 above the California annual outdoor standard of 30 ppb.
© 2020 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  codes and standards; fine particulate matter; formaldehyde; multifamily; nitrogen dioxide; range hood

Year:  2020        PMID: 33070378     DOI: 10.1111/ina.12764

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  4 in total

1.  Reduction of environmental chemicals, toxicity and particulate matter in wet scrubber device to achieve zero emissions.

Authors:  Krishnaraj Ramaswamy; Leta Tesfaye Jule; Nagaprasad N; Kumaran Subramanian; Shanmugam R; Priyanka Dwarampudi L; Venkatesh Seenivasan
Journal:  Sci Rep       Date:  2022-06-02       Impact factor: 4.996

2.  Factors Impacting Range Hood Use in California Houses and Low-Income Apartments.

Authors:  Haoran Zhao; Wanyu R Chan; William W Delp; Hao Tang; Iain S Walker; Brett C Singer
Journal:  Int J Environ Res Public Health       Date:  2020-11-28       Impact factor: 3.390

Review 3.  Indoor Air Quality in Buildings: A Comprehensive Review on the Factors Influencing Air Pollution in Residential and Commercial Structure.

Authors:  Mehzabeen Mannan; Sami G Al-Ghamdi
Journal:  Int J Environ Res Public Health       Date:  2021-03-22       Impact factor: 3.390

4.  Improving the Indoor Air Quality in Nursery Buildings in United Arab Emirates.

Authors:  Mohammad Arar; Chuloh Jung
Journal:  Int J Environ Res Public Health       Date:  2021-11-18       Impact factor: 3.390

  4 in total