Literature DB >> 33065746

Accuracy of Placement of Pedicle Screws in the Lumbosacral Region of Dogs Using 3D-Printed Patient-Specific Drill Guides.

Cristina Toni1, Bill Oxley2, Stephen Clarke3, Sebastien Behr1.   

Abstract

OBJECTIVE: The aim of this study was to report the accuracy of pedicle screw placement using three-dimensional (3D)-printed, patient-specific drill guides in the lumbosacral region of dogs. STUDY
DESIGN: This was a retrospective study. Thirty-two pedicle screws were placed in five dogs. Medical records were reviewed between November 2015 and November 2018 for dogs showing clinical signs associated with cauda equina syndrome. Inclusion criteria included preoperative magnetic resonance imaging, pre- and postoperative computed tomography (CT) and dorsal stabilization, with pedicle screws placed using 3D-printed, patient-specific drill guides and polymethylmethacrylate. Screw placement was evaluated for medial or lateral breaching on postoperative CT.
RESULTS: Five dogs met the inclusion criteria. Four had degenerative lumbosacral stenosis and one had discospondylitis. All dogs had failed medical management prior to surgery. Of 32 bicortical pedicle screws placed, 30 were fully contained inside the pedicle and 2 were partially breaching the vertebral canal (less than one-third of the screw diameter). Postoperative CT revealed good alignment of L7-S1 in all planes.
CONCLUSION: This technique enabled an accurate and safe placement of pedicle screws in the lumbosacral region of dogs with lumbosacral disease. Three-dimensional, printed patient-specific drill guides are a safe and effective method of placing pedicle screws in dogs with lumbosacral disease. Thieme. All rights reserved.

Entities:  

Year:  2020        PMID: 33065746     DOI: 10.1055/s-0040-1716840

Source DB:  PubMed          Journal:  Vet Comp Orthop Traumatol        ISSN: 0932-0814            Impact factor:   1.358


  3 in total

Review 1.  Clinical applications and prospects of 3D printing guide templates in orthopaedics.

Authors:  Meng Meng; Jinzuo Wang; Tianze Sun; Wentao Zhang; Jing Zhang; Liming Shu; Zhonghai Li
Journal:  J Orthop Translat       Date:  2022-05-13       Impact factor: 4.889

2.  Case Report: Clinical Use of a Patient-Individual Magnetic Resonance Imaging-Based Stereotactic Navigation Device for Brain Biopsies in Three Dogs.

Authors:  Sarah Gutmann; Thomas Flegel; Marcel Müller; Robert Möbius; Kaspar Matiasek; Florian König; Dirk Winkler; Ronny Grunert
Journal:  Front Vet Sci       Date:  2022-07-14

3.  Accuracy of a patient-specific 3D-printed drill guide for placement of bicortical screws in atlantoaxial ventral stabilization in dogs.

Authors:  Yong Yu; Jinsu Kang; Namsoo Kim; Suyoung Heo
Journal:  PLoS One       Date:  2022-08-01       Impact factor: 3.752

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.