Inclusion of quasi-vertex views in a brain-dedicated multi-pinhole SPECT system for improved imaging performance.

Benjamin Auer1, Navid Zeraatkar1, Justin C Goding1, Arda Könik2, Timothy J Fromme3, Kesava S Kalluri1, Lars R Furenlid4,5, Phillip H Kuo5, Michael A King1.   

Abstract

With brain-dedicated multi-detector systems employing pinhole apertures the usage of detectors facing the top of the patient's head (i.e. quasi-vertex (QV) views) can provide the advantage of additional viewing from close to the brain for improved detector coverage. In this paper, we report the results of simulation and reconstruction studies to investigate the impact of the QV views on the imaging performance of AdaptiSPECT-C, a brain-dedicated stationary SPECT system under development. In this design, both primary and scatter photons from regions located inferior to the brain can contribute to SPECT projections acquired by the QV views, and thus degrade AdaptiSPECT-C imaging performance. In this work, we determined the proportion, origin, and nature (i.e. primary, scatter, and multiple-scatter) of counts emitted from structures within the head and throughout the body contributing to projections from the different AdaptiSPECT-C detector rings, as well as from a true vertex view detector. We simulated phantoms used to assess different aspects of image quality (i.e. uniform activity concentration sphere, and Derenzo), as well as anthropomorphic phantoms with different count levels emulating clinical 123I activity distributions (i.e. DaTscan and perfusion). We determined that attenuation and scatter in the patient's body greatly diminish the probability of the photons emitted outside the volume of interest reaching to detectors and being recorded within the 15% photopeak energy window. In addition, we demonstrated that the inclusion of the residual of such counts in the system acquisition does not degrade visual interpretation or quantitative analysis. The addition of the QV detectors improves volumetric sensitivity, angular sampling, and spatial resolution leading to significant enhancement in image quality, especially in the striato-thalamic and superior regions of the brain. Besides, the use of QV detectors improves the recovery of clinically relevant metrics such as the striatal binding ratio and mean activity in selected cerebral structures. Our findings proving the usefulness of the QV ring for brain imaging with 123I agents can be generalized to other commonly used SPECT imaging agents labelled with isotopes, such as 99mTc and likely 111In.

Entities:  

Mesh:

Year:  2021        PMID: 33065564     DOI: 10.1088/1361-6560/abc22e

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   4.174


  4 in total

1.  Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Arda Konik; Timothy J Fromme; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 10.048

2.  Cerebral SPECT imaging with different acquisition schemes using varying levels of multiplexing versus sensitivity in an adaptive multi-pinhole brain-dedicated scanner.

Authors:  Navid Zeraatkar; Kesava S Kalluri; Benjamin Auer; Micaehla May; R Garrett Richards; Lars R Furenlid; Phillip H Kuo; Michael A King
Journal:  Biomed Phys Eng Express       Date:  2021-09-22

3.  Multiple-pinhole collimators improve intra- and between-rater agreement and the certainty of the visual interpretation in dopamine transporter SPECT.

Authors:  Franziska Mathies; Ivayla Apostolova; Lena Dierck; Janin Jacobi; Katja Kuen; Markus Sauer; Michael Schenk; Susanne Klutmann; Attila Forgács; Ralph Buchert
Journal:  EJNMMI Res       Date:  2022-08-17       Impact factor: 3.434

4.  Design Study of an Ultrahigh Resolution Brain SPECT System Using a Synthetic Compound-Eye Camera Design With Micro-Slit and Micro-Ring Apertures.

Authors:  Elena Maria Zannoni; Can Yang; Ling-Jian Meng
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.