| Literature DB >> 33064464 |
Chen Wang1, Brandon Bottorff2, Emily Reidy2, Colleen Marciel F Rosales3, Douglas B Collins1,4, Atila Novoselac5, Delphine K Farmer6, Marina E Vance7, Philip S Stevens2,3, Jonathan P D Abbatt1.
Abstract
The relative importance of common activities on indoor nitrous acid (HONO) mixing ratios was explored during high time resolution, month-long measurements by chemical ionization mass spectrometry in a previously unoccupied house. Indoor HONO varied from 0.2 to 84.0 ppb (mean: 5.5 ppb; median 3.8 ppb), an order of magnitude higher than simultaneously measured outdoor values, indicating important indoor sources. They agree well with simultaneous measurements of HONO by Laser-Photofragmentation/Laser-Induced Fluorescence. Before any combustion activities, the mixing ratio of 3.0 ± 0.3 ppb is indicative of secondary sources such as multiphase formation from NO2. Cooking (with propane gas), especially the use of an oven, led to significant enhancements up to 84 ppb, with elevated mixing ratios persisting for a few days due to slow desorption from indoor surface reservoirs. Floor bleach cleaning led to prolonged, substantial decreases of up to 71-90% due to reactive processes. Air conditioning modulated HONO mixing ratios driven by condensation to wet surfaces in the AC unit. Enhanced ventilation also significantly lowered mixing ratios. Other conditions including human occupancy, ozone addition, and cleaning with terpene, natural product, and vinegar cleaners had a much smaller influence on HONO background levels measured following these activities.Entities:
Year: 2020 PMID: 33064464 DOI: 10.1021/acs.est.0c05356
Source DB: PubMed Journal: Environ Sci Technol ISSN: 0013-936X Impact factor: 9.028