Literature DB >> 33063489

[Calcaneal plate bridge reconstruction plate for acetabular fracture involving quadrilateral surface via modified Stoppa approach].

Deshun Yang1, Yangyang Wang1, Kaiming Wang1, Liang Liao1, Bingjun Lei1, Zhen Huang1, Qing Zhang1.   

Abstract

OBJECTIVE: To explore the effectiveness of the calcaneal plate bridge reconstruction plate for acetabular fracture involving quadrilateral surface via modified Stoppa approach.
METHODS: Between January 2015 and December 2017, 18 patients with acetabular fracture involving quadrilateral surface were treated with the calcaneal plate bridge reconstruction plate via the modified Stoppa approach. There were 12 males and 6 females. The age ranged from 28 to 63 years (mean, 39 years). The cause of injury was traffic accident in 13 cases and falling from height in 5 cases. According to the Letournel-Judet classification, there were 10 cases of anterior and posterior column fractures, 6 cases of T-shaped fractures, and 2 cases of anterior column and posterior semi-transevere fractures. The interval from injury to operation was 6 to 24 days (mean, 8.6 days). The reduction quality was assessed by postoperative X-ray film and CT according to the criteria proposed by Matta. The hip joint function was assessed by the modified Merled'Aubigné-Postel score.
RESULTS: The operation time was 120-240 minutes (mean, 165 minutes) and the intraoperative blood loss was 600-1 400 mL (mean, 850 mL). All patients were followed up 18-30 months (mean, 24.5 months). There were 2 cases of the fat liquefaction of abdominal incisions, 3 cases of intraoperative injury of lateral femoral cutaneous nerve, 1 case of lower limb thrombosis, and 1 case of abdominal pain and hematuria due to intraoperative accidental bladder injury. According to the criteria proposed by Matta, the reduction quality rated as anatomic reduction in 12 cases, satisfactory reduction in 5 cases, and unsatisfied reduction in 1 case, and the satisfaction rate was 94.4%. All fractures healed with the healing time of 3-5 months (mean, 3.4 months). During follow-up, no internal fixator loosening, breakage, or fracture displacement occurred. At last follow-up, according to modified Merled'Aubigné-Postel score, hip joint functions rated as excellent in 11 cases, good in 4 cases, fair in 2 cases, and poor in 1 case. The excellent and good rate was 83.3%.
CONCLUSION: Application of calcaneal plate bridge reconstruction plate via the modified Stoppa approach for the acetabular fracture involving the quadrilateral surface can obtain satisfactory effectiveness.

Entities:  

Keywords:  Acetabular fracture; calcaneal plate; internal fixation; modified Stoppa approach; quadrilateral surface; reconstruction plate

Mesh:

Year:  2020        PMID: 33063489      PMCID: PMC8171867          DOI: 10.7507/1002-1892.202003198

Source DB:  PubMed          Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi        ISSN: 1002-1892


  11 in total

1.  Generating stability in elderly acetabular fractures-A biomechanical assessment.

Authors:  Clay A Spitler; Dirk Kiner; Rachel Swafford; Daniel Doty; Ron Goulet; LaRita C Jones; Josie Hydrick; Peter Nowotarski
Journal:  Injury       Date:  2017-07-24       Impact factor: 2.586

2.  Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury.

Authors:  J M Matta
Journal:  J Bone Joint Surg Am       Date:  1996-11       Impact factor: 5.284

3.  Operative treatment of acetabular fractures through the ilioinguinal approach. A 10-year perspective.

Authors:  J M Matta
Journal:  Clin Orthop Relat Res       Date:  1994-08       Impact factor: 4.176

4.  [Effectiveness of acetabular transverse and posterior wall fractures by Kocher-Langenbeck approach].

Authors:  Licheng Zhang; Meng Xu; Chunqing He; Hailong Du; Hua Chen; Yizhu Guo; Sheng Tao; Qun Zhang; Xiangdang Liang; Peifu Tang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2010-12

5.  Fixation of quadrilateral plate fractures of the acetabulum using the buttress screw: A novel technique.

Authors:  Mahmoud Abdel Karim; Ahmed Hazem Abdelazeem; Mohamed Youness; Walid A El Nahal
Journal:  Injury       Date:  2017-05-24       Impact factor: 2.586

6.  The use of buttress plates in the management of acetabular fractures with quadrilateral plate involvement: is it still a valid option?

Authors:  Theodoros H Tosounidis; Suribabu Gudipati; Michalis Panteli; Nikolaos K Kanakaris; Peter V Giannoudis
Journal:  Int Orthop       Date:  2015-07-24       Impact factor: 3.075

7.  Modified stoppa approach for acetabular fractures with anterior and posterior column displacement: quantification of radiographic reduction and analysis of interobserver variability.

Authors:  Romney C Andersen; Robert V O'Toole; Jason W Nascone; Marcus F Sciadini; H Michael Frisch; Clifford W Turen
Journal:  J Orthop Trauma       Date:  2010-05       Impact factor: 2.512

8.  [BIOMECHANICAL COMPARATIVE STUDY ON FOUR INTERNAL FIXATIONS FOR ACETABULAR FRACTURES IN QUADRILATERAL AREA].

Authors:  Lei Wang; Xiaobo Wu; Wei Qi; Yongbin Wang; Quanjie He; Fengsong Xu; Hongyang Liu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2015-10

9.  Biomechanical Comparison of Intrapelvic and Extrapelvic Fixation for Acetabular Fractures Involving the Quadrilateral Plate.

Authors:  Gregory J Gillispie; Sharon N Babcock; Kyle P McNamara; Michaela E Dimoff; Arun Aneja; Philip J Brown; Eben A Carroll
Journal:  J Orthop Trauma       Date:  2017-11       Impact factor: 2.512

10.  [MODIFIED Stoppa APPROACH WITH MEDIAL WALL SPRING PLATE FOR INVOLVING QUADRILATERAL OF ACETABULUM FRACTURE].

Authors:  Yajun Yang; Jianming Yue; Peng Wen
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2015-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.