Literature DB >> 33053239

Electrospray ionization and heterogeneous matrix effects in liquid chromatography/mass spectrometry based meta-metabolomics: A biomarker or a suppressed ion?

Hikmat Ghosson1,2, Yann Guitton3, Amani Ben Jrad1,2, Chandrashekhar Patil1, Delphine Raviglione1,2, Marie-Virginie Salvia1,2, Cédric Bertrand1,2,4.   

Abstract

RATIONALE: Correct biomarker determination in metabolomics is crucial for unbiased conclusions and reliable applications. However, this determination is subject to several drifts, e.g. matrix effects and ion suppression in Liquid Chromatography/Mass Spectrometry (LC/MS)-based approaches. This phenomenon provokes critical issues for biomarker determination, particularly during comparative studies dealing with samples exhibiting heterogeneous complexities.
METHODS: Occurrence of the issue was coincidentally noticed when studying the environmental impact of a complex bioinsecticide: Bacillus thuringiensis israelensis. The studied samples comprised insecticide-spiked sediments and untreated control sediments. QuEChERS extractions followed by LC/ESI-Q/ToF analyses were performed on sediments after 15 days of incubation. Meta-metabolomes containing pesticide xenometabolites and sediment endometabolites were analyzed in depth using XCMS-based computational data preprocessing. Multivariate statistical analyses (PCA, OPLS-DA) and raw data crosschecks were performed to search for environmental biomarkers.
RESULTS: Multivariate analyses and raw data crosschecks led to the selection of nine metabolites as biomarker candidates. However, when exploring the mass spectra, co-elutions were noticed between seven of these metabolites and multi-charged macromolecules originating from the pesticide. Provoked false positives were thus suspected due to a potential ion suppression exclusively occurring in the spiked samples. A dilution-based approach was then applied. It confirmed five metabolites as suppressed ions.
CONCLUSIONS: Ion suppression should be considered as a critical issue for biomarker determination when comparing heterogeneous metabolic profiles. Raw chromatograms and mass spectra crosschecks are mandatory to reveal potential ion suppressions in such cases. Dilution is a suitable approach to filter reliable biomarker candidates before their identification and absolute quantification.
© 2020 John Wiley & Sons, Ltd.

Entities:  

Year:  2021        PMID: 33053239     DOI: 10.1002/rcm.8977

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  1 in total

1.  Fast and easy multiresidue method employing acetonitrile extraction/partitioning and "dispersive solid-phase extraction" for the determination of pesticide residues in produce.

Authors:  Michelangelo Anastassiades; Steven J Lehotay; Darinka Stajnbaher; Frank J Schenck
Journal:  J AOAC Int       Date:  2003 Mar-Apr       Impact factor: 1.913

  1 in total
  1 in total

1.  Challenges in Translating Clinical Metabolomics Data Sets from the Bench to the Bedside.

Authors:  Candice Z Ulmer; Anthony Maus; Jolaine Hines; Ravinder Singh
Journal:  Clin Chem       Date:  2021-11-26       Impact factor: 8.327

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.