Mid-Term Results of Endovascular Aneurysm Sealing in the Treatment of Abdominal Aortic Aneurysm With Unfavorable Morphology.

Łukasz Dzieciuchowicz1, Jolanta Tomczak2, Ewa Strauss2,3, Grzegorz Oszkinis4.   

Abstract

PURPOSE: To report mid-term results of endovascular aneurysm sealing (EVAS) of abdominal aortic aneurysms (AAA) deemed unsuitable for a standard endovascular aneurysm repair (EVAR).
METHODS: A prospectively maintained database of 42 patients with EVAR-unfavorable anatomy treated by EVAS combined with chimney grafts in case of the proximal AAA neck shorter than 5 mm was analyzed. Early outcomes included final angiographic result, intra- and early post-operative deaths, and complications. Mid-term outcomes included all-cause mortality (ACM), aneurysm-related mortality (ARM), patency of the stents, occurrence of endoleaks, serious complications and graft failures defined as the AAA growth of more than 5 mm, type I endoleak, occlusion of the stent-graft or chimney graft, aorto-duodenal fistula, or aneurysm rupture.
RESULTS: The procedure was completed in all patients. Twenty-eight chimney grafts were implanted in 19 patients. Patients were followed for a median of 24 months (range 12-34 months). There were 2 intraoperative ruptures and 1 patient died in an early postoperative period. The cumulative ACM was 15, 21, and 36% at 12, 24, and 36 months, respectively, and the cumulative ARM was 8, 11, and 27% at 12, 24, and 36 months, respectively. Three out of 5 aneurysm-related deaths were due to a secondary aorto-duodenal fistula. The cumulative incidence of graft failure was 20, 27, and 42% at 12, 24, and 36 months, respectively. The cumulative incidence of an endoleak was 5, 9, and 23% at 12, 24, and 36 months, respectively. The graft failure increased significantly both ACM (p = .012) and ARM (p = .00003). The implantation of chimney grafts at the initial procedure increased ARM significantly (p = .008). The presence of an endoleak did not have any significant influence on ACM and ARM.
CONCLUSION: Patients treated with EVAS for AAAs with EVAR-unfavorable anatomy, especially those with chimney grafts, exhibit a high risk of graft failure and subsequent death.

Entities:  

Keywords:  Nellix device; abdominal aortic aneurysm; chimney grafts; endovascular aneurysm sealing; outside IFU

Mesh:

Year:  2020        PMID: 33034263     DOI: 10.1177/1538574420965736

Source DB:  PubMed          Journal:  Vasc Endovascular Surg        ISSN: 1538-5744            Impact factor:   1.089