Literature DB >> 33031178

A novel method to assess valvulo-arterial load in patients with aortic valve stenosis.

Sara L Hungerford1,2,3, Audrey I Adji1,2,3,4, Nicole K Bart1,2,3, Linda Lin1, Mayooran J Namasivayam1,2,3, Bruno Schnegg1, Andrew Jabbour1,2,3, Michael F O'Rourke1,2,3, Christopher S Hayward1,2,3, David W M Muller1,2,3.   

Abstract

INTRODUCTION: Ventricular function in elderly patients with aortic stenosis is impeded both by restricted aortic flow and arterial stiffening. A number of patients continue to have exertional intolerance after relief of aortic valvular obstruction due to unrecognized ventriculo-arterial coupling mismatch. HYPOTHESIS: Quantification of valvulo-arterial load (VAL), using a simultaneous applanation tonometry/cardiac magnetic resonance (CMR) technique, can accurately assess the relative contributions of aortic stiffness and valve gradient in older patients with aortic stenosis.
METHODS: Elderly patients with aortic stenosis underwent a simultaneous applanation tonometry/CMR protocol. CMR provided left ventricular volume and aortic flow simultaneously with radial applanation tonometry pressure acquisition. Central aortic pressure was derived by transformation of the radial applanation tonometry waveform. VAL was determined as the relationship of derived aortic pressure to CMR aortic flow in frequency domain (central illustration).
RESULTS: Twenty patients (age 80 ± 9 years; 12 males; blood pressure 140/75 ± 20 mmHg) with aortic stenosis on transthoracic echocardiogram (16 severe; mean gradient 45 ± 16 mmHg; aortic valve area 0.8 ± 0.2 cm2) were enrolled. Derived aortic pressure and flow waveforms correlated well with invasive data. Increased VAL was significantly associated with advanced age (P = 0.04) and raised SBP (P < 0.01), irrespective of aortic stenosis severity.
CONCLUSION: Difficulties in the measurement and accuracy of ventriculo-arterial coupling means that it is not routinely measured in patients with aortic stenosis. We describe a new noninvasive index that provides an accurate assessment of valvular and arterial load on the left ventricle. VAL may help detect those at risk of ventriculo-arterial coupling mismatch and assist in selection of those most likely to benefit from an invasive procedure.
Copyright © 2020 Wolters Kluwer Health, Inc. All rights reserved.

Entities:  

Year:  2021        PMID: 33031178     DOI: 10.1097/HJH.0000000000002648

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  3 in total

Review 1.  New Evidence About Aortic Valve Stenosis and Cardiovascular Hemodynamics.

Authors:  Costantino Mancusi; Edda Bahlmann; Christian Basile; Eva Gerdts
Journal:  High Blood Press Cardiovasc Prev       Date:  2022-04-19

2.  Ageing, hypertension and aortic valve stenosis - Understanding the series circuit using cardiac magnetic resonance and applanation tonometry.

Authors:  S L Hungerford; A I Adji; N K Bart; L Lin; N Song; A Jabbour; M F O'Rourke; C S Hayward; D W M Muller
Journal:  Int J Cardiol Hypertens       Date:  2021-05-28

3.  Validation study to determine the accuracy of central blood pressure measurement using the SphygmoCor XCEL cuff device in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement.

Authors:  Jose M De la Torre Hernández; Gabriela Veiga Fernandez; Jonathan Brown; Fermin Sainz Laso; Dae-Hyun Lee; Victor Fradejas; Tamara Garcia Camarero; Sammy Elmariah; Ignacio Inglessis; Javier Zueco; Jose A Vazquez de Prada; Eyal Ben-Assa; Elazer R Edelman
Journal:  J Clin Hypertens (Greenwich)       Date:  2021-05-04       Impact factor: 3.738