COVID-19 pandemic consciousness: droplet contamination and aerosolization during pleural decompression.

Sunjuri Sun1, Nandhini Ravintharan1, Karishma Jassal1,2, Rohan Nandurkar1, Kim Yesul2,3, Ellaine Boo1,2, De Villiers Smit2,4, Mark Fitzgerald1,2.   

Abstract

Entities:  

Year:  2020        PMID: 33030221      PMCID: PMC7675369          DOI: 10.1111/ans.16388

Source DB:  PubMed          Journal:  ANZ J Surg        ISSN: 1445-1433            Impact factor:   1.872


× No keyword cloud information.
In response to the current coronavirus disease 2019 (COVID‐19) pandemic, it has been argued that pleural decompression (PD) is an aerosol‐generating procedure (AGP) and that personal protective equipment (PPE) provides adequate protection. Droplet transmission occurs when infectious droplets, generally greater than 5–10 μm, come in contact with another person's mucosa. Conversely, airborne transmission occurs via droplet nuclei or aerosols. An aerosol is a suspension of particles (such as a liquid or solid particle) within a gas. We investigated this by simulating and mapping viral droplet contamination during PD and intercostal catheter (ICC) insertion in the setting of trauma to elucidate the hazard to the clinician during this pandemic. Ethical approval was gained from the institutional review board. We constructed a model using the Life/form Chest Tube Manikin (3B Scientific, Hamburg, Germany), designed specifically for PD and ICC insertion. To simulate a tension haemopneumothorax, the manikin's hemi‐thoraces were filled with ~1000 mL of red‐dyed water, 2 mm of 100 mg/mL fluorescein and ~500 mL of air. The proceduralist was a Royal Australasian College of Surgeons Fellow in General Surgery and Trauma wearing the currently recommended PPE for AGPs, which included an N95 mask, a face shield visor, a surgical cap, a long‐sleeved surgical gown and gloves. The manikin was placed supine on an operating table. A standard open cut‐down technique used by the Alfred Hospital Trauma Service was employed to decompress the right pleural space. A skin incision was made at the fifth intercostal space anterior to the mid‐axillary line, blunt dissection was carried out down through the chest wall and the pleural space was entered bluntly with a haemostat. A finger thoracostomy was performed and a 28‐Fr ICC was then inserted into the right pleural space. The procedure was filmed, and photographs were taken in normal lighting and under blue light to visually assess fluorescent marker contamination. Post‐procedure, areas of red fluid were visible on both gloves, the right dominant forearm and waist of the gown. There was no visible contamination to head, neck or chest of the proceduralist under normal lighting (Fig. 1).
Fig 1

(a) Visible contamination of procedural field and proceduralist's gloves. (b) Proceduralist with no visible contamination to head, neck or chest of the proceduralist under normal lighting post‐procedure.

(a) Visible contamination of procedural field and proceduralist's gloves. (b) Proceduralist with no visible contamination to head, neck or chest of the proceduralist under normal lighting post‐procedure. However, under blue light, droplet contamination not visible to the naked eye was visible extending onto the visor, both shoulders and chest (Figs 2, 3).
Fig 2

(a) Proceduralist's dominant right shoulder with visible contamination under blue light post‐procedure. (b) Proceduralist's non‐dominant left shoulder with visible contamination under blue light post‐procedure.

Fig 3

(a) Proceduralist's chest with visible contamination under blue light post‐procedure. (b) Proceduralist's visor with visible contamination under blue light post‐procedure.

(a) Proceduralist's dominant right shoulder with visible contamination under blue light post‐procedure. (b) Proceduralist's non‐dominant left shoulder with visible contamination under blue light post‐procedure. (a) Proceduralist's chest with visible contamination under blue light post‐procedure. (b) Proceduralist's visor with visible contamination under blue light post‐procedure. COVID‐19 caused by the severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) emerged in Wuhan, China, in late 2019. The World Health Organization declared a global health emergency on 31 January 2020. The primary mode of SARS‐CoV‐2 transmission is thought to be via droplet transmission, as well as object and surface fomite contamination within the infected person's environment. Airborne transmission of SARS‐CoV‐2 is considered possible during AGPs, including endotracheal intubation, bronchoscopy and positive pressure ventilation. Surgeons and emergency physicians commonly perform PD in the setting of trauma. Aerosolization is plausible when pressurized gas escapes from the pleural space. The British Thoracic Society recommends that level 2 PPE should be worn during PD, including an FFP‐3 mask, visor, gloves and a long‐sleeved gown.4, 5 It has been speculated that chest drains with active air leak may also potentially generate aerosols, as gas can bubble through the chest drain bottle and escape via the suction port. However, literature/quantitative evidence on this subject is limited. We used a fluorescent agent widely used in infection control that can simulate contamination. It is commonly used for evaluation of hand hygiene in schools and industry settings, donning and doffing PPE, simulations for SARS and Ebola virus and assessing surgical contamination of equipment and splatter contamination in dental practices.7, 8, 9, 10 In our simulation, we observed patches of the fluorescent marker extending onto the proceduralist's visor, shoulders and chest without visible red staining. In this simulation, the PPE described appeared to provide adequate barrier protection. This re‐emphasizes the caution required when performing PD. Appropriate PPE including a face shield visor, long‐sleeved impermeable gown, respirator mask, impermeable footwear, surgical cap and gloves should be worn to provide aerosol barrier protection. Healthcare staff should advocate for the use of ‘buddy surveillance’ whilst doffing PPE wearables post PD to reduce the risk of self‐contamination. In conclusion, our simulation demonstrates that droplet contamination to the proceduralist occurs during PD. It is highly plausible that aerosolization occurs as well, although this may not be visible to the naked eye. There appears to be no other studies, to date, reporting on the evidence relating to this subject.

Author Contributions

Sunjuri Sun: Writing‐original draft; writing‐review and editing. Nandhini Ravintharan: Writing‐original draft; writing‐review and editing. Karishma Jassal: Conceptualization; writing‐original draft. Rohan Nandurkar: Project administration. Yesul Kim: Project administration. Ellaine Boo: Project administration. DeVilliers Smit: Supervision. Mark Fitzgerald: Conceptualization; supervision.
  1 in total

1.  SARS-CoV-2 infection rate in Antananarivo frontline health care workers, Madagascar.

Authors:  Rila Ratovoson; Mihaja Raberahona; Rado Razafimahatratra; Lova Randriamanantsoa; Emmanuel Harizaka Andriamasy; Perlinot Herindrainy; Norosoa Razanajatovo; Soa Fy Andriamandimby; Andoniaina Rakotonaivo; Fanirisoa Randrianarisaona; Philippe Dussart; Jean Michel Heraud; Mamy Jean de Dieu de Randria; Matthieu Schoenhals; Rindra Vatosoa Randremanana
Journal:  Influenza Other Respir Viruses       Date:  2022-06-26       Impact factor: 5.606

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.