Investigation of hospital indoor air quality for the presence of SARS-Cov-2.

Hossein Masoumbeigi1, Ghader Ghanizadeh2, Reza Yousefi Arfaei3, Soleyman Heydari4, Hassan Goodarzi5, Ruhollah Dorostkar Sari6, Mehdi Tat6.   

Abstract

PURPOSE: Unidentified dynamics for the causative agent of COVID-19, SARS-Cov-2, led to the critical public health issue. Suspicion for the airborne potential of SARS-Cov-2 is an important problem for its transmission and relevant epidemics. This research investigated hospital indoor air quality to SARS-Cov-2 occurrence and determination its air born potential.
METHODS: The site study was a referral hospital with 630 beds for admitting of COVID-19 patients. Air sampling was done (n = 31) on selected wards including Emergency 1, Emergency 2, bedridden (4-B, 10-D), ICU 2, ICU 3, CT-SCAN, and laundry. The average temperature and relative humidities were 22 ± 1 °C and 43 percent respectively. All glass impinger used for sampling in which the sampling pumps capacities were 5 and 40 L.min- 1. Sampling duration time was 20 and 15 minutes and 100 to 1000 L of air were gathered. All parts of the sampling equipment were completely disinfected by hot water, ethanol (70%), chlorine solution (1000 ppm), hot water (70 °C for 1 min) and washed with distilled water. The transmitting media (7 ml) was injected into impinger and residual of this media (2 ml) was sent to the virology laboratory within 2 hours and preserved on refrigerator < 4 °C. Analysis of samples was performed by RT-PCR and repeated for accuracy control.
RESULTS: All of the samples were negative for SARS-Cov-2 occurrence. These results showed that SARS-Cov-2 had not airborne potential in this hospital.
CONCLUSIONS: Although SARS-Cov-2 similar to the SARS virus but, SARS-Cov-2 is not an airborne virus. © Springer Nature Switzerland AG 2020.

Entities:  

Keywords:  Airborne; COVID-19; Hospital; Indoor air quality; SARS-Cov-2

Year:  2020        PMID: 33014385      PMCID: PMC7525766          DOI: 10.1007/s40201-020-00543-3

Source DB:  PubMed          Journal:  J Environ Health Sci Eng


Introduction

Induced respiratory illnesses by viral infections are the most frequent causes of morbidity and mortality worldwide [1]. SARS-CoV-2 is a member of the coronavirus family which temporarily named as SARS-Cov-2 and the causative agent of COVID-19 [2]. The COVID-19 as an acute respiratory viral disease emerged in the last days of 2019 and on March 11, 2020, WHO declared its pandemic scale [3, 4]. The dynamics of SARS-Cov-2 are now unknown, but there is speculation that it has an animal origin and have the airborne potential [2]. Besides the indefinite treatment process for COVID-19 and lack of a vaccine against its responsible pathogen, suspicion for the airborne potential of SARS-Cov-2 is another probable challenge for SARS-Cov-2 transmission and management of related pandemics [5, 6]. These problems led to inducing regional and global release potential of virus, the elevation of the basic reproduction number, R0, (Basic reproduction number) of COVID-19, occurring of several thousands of morbidity, mortality, and complication of health care services worldwide [7]. To date, over 200 developed and developing countries are suffering from COVID-19, so, in many of these countries, the health care services resiliency has critical issues for patients management [3]. Different, indistinguishable, and complicated transmission mechanisms of SARS-Cov-2 are a crucial challenge for health care policymakers which led to their astonishment on epidemics control [8, 9]. Although transmission of SARS-Cov-2 was not identified completely, several transmission mechanisms including emission by respiratory droplets, direct contact with contaminated surfaces, and airborne mechanisms are introduced for its transmission [10]. Airborne characteristics of microorganisms including viruses can lead to elevation of infectious potential and complication of epidemics control. So, airborne viruses can represent major health and economic risks. In epidemics and pandemics, the efficacy of preventive action plans depend on transmission chain disconnection levels and identification of pathogenic mechanisms of agents, so, based on introduced transmission mechanisms for SARS-Cov-2, its aerobiology, and transmission paths of the virus with analyzing of microbiological content of air is very important [11]. A retrospective cohort study reported that airborne transmission may have played an important role in SARS transmission [11]. Due to airborne transmission of foot-and-mouth disease virus (FMDV: a picornavirus that causes vesicles in the mouth and feet of bovids, suids, ovids, caprids, and other cloven-hoofed animals, is highly infectious and a major plague of animal farming.) and Norwalk-like virus reported in previous studies, aerosols may also be responsible for the transmission of COVID-19 and other viral diseases. Since the airborne potential of SARS-Cov-2 is controversial, according to the abovementioned issues, the purpose of this study is the investigation of the airborne potential of SARS-Cov-2 in a large hospital as representative of medical staff workplace.

Materials and methods

This research was investigated by the indoor air quality of a military hospital for the presence of SARS-Cov-2. The hospital in question was a large military hospital located in District 2 of Tehran municipality with 600 beds. Air sampling was done in selected wards of this referral hospital for admitting of COVID-19 patients, including Emergency 1, Emergency 2, bedridden (4-B, 10-D), ICU 2, ICU 3, CT-SCAN (Computed tomography scan) and laundry wards. Bed distance in rooms and ICU wards was 1 meter without any separator. All investigated wards were fully occupied in which patients had an oxygen mask. Only in the ICU ward with the intubated and critical patients, without disturbance in nursing care, the patient’s beds were separated by transparent nylon drapes from the nursing station. Air pressure in hospital wards had atmospheric conditions and not measured. Central air conditioning with positive pressure was used in hospital wards. The average temperature and relative humidity were 22 ± 1 °C and 43 percent respectively. Air sampling was performed within 5 days by all-glass impinger (AGI) [11] in which sampling pumps capacities were 5 L.min− 1 (SKS pump, P1) and 40 L.min− 1(P2). Sampling pumps were calibrated by dry air calibrator (DRY GAS METER. SHINAGAWA SEIJI CI. LTD. TOKYO, KYOTO, FUKUOKA.). Sampling duration time was 20 and 15 minutes and 100 to 1000 L of air were gathered by P1 in randomized stations and P2, respectively. Sampling with P1 was performed on randomized stations and P2 with circulation patterns and without stand stations. Air sampling setup installed about 1.2 to 1.8 m from the floor and approximately 0.5 to 4 m away from patients’ beds. Before each sampling, all parts of the sampling equipment including AGI parts and vessels completely disinfected by hot water (70 °C for 1 min), chlorine solution (1000 ppm), ethanol (70%), hot water (70 °C for 1 min) and washed with sterile distilled water. The volume of air collected was in the range of 100 to 1000 L. The transmitting media (7 ml) was injected into glass impinger and after sampling residual of this media (2 ml) were sent to virology laboratory within 2 hours. All samples were stored at 4 °C until sent to the virology laboratory. Analysis of samples was performed by RT-PCR (Reverse transcriptase polymerase chain reaction) and repeated for accuracy control. The one-step rRT-PCR (Real time Reverse transcriptase polymerase chain reaction) assay was developed using the QuantiFast RT-PCR Kit (Qiagen, Hilden, Germany), using the Corbet (Rotor-Gene) 6000 (Qiagen, Germany) and Applied Biosystems (ABI) 7500 (USA) real-time PCR instruments. The amplifications were accomplished within 1 hour, in 20 µL reaction mixtures containing 5 µL of the targeted viral RNA and 2 µL (20 pmol) of each primer (10 µM). The cycling conditions were as follows: a single cycle of 10 minutes at 50 °C and 3 minutes at 95 °C, followed by 40 cycles of 10 seconds at 95 °C, and a final cycle of 30 seconds at 60 °C [12]. The rRT-PCR products were detected via an increase in fluorescence from cycle to cycle, and the positive and negative controls were used as the quality controls for the process. The real-time analysis was evaluated with negative and positive controls. The rRT-PCR amplicons were then confirmed via electrophoresis.

Results and discussion

All of the patients had a severe form of cough and sneezing. Patients’ O2 saturation ranging from 54 to 93 percent. All of the patients had an oxygen mask in bedridden wards and ICUs. In ICU3 and ICU2, three and two patients were intubated, respectively. Gender classification of patients was not considered. The average of patients old in bedridden wards and ICUs were 55 and 65 years, respectively. All of the samples were negative for SARS-Cov-2 occurrence (Table 1). Complementary information of investigated wards was informed in Table 2, which implies that all investigated wards had central, mechanical, and positive pressure ventilation systems. These results showed that SARS-Cov-2 had not airborne potential in this hospital. These results concur with WHO reports which considered in previous research by Faridi et al. [13]. Also, Faridi and et al. were investigated the airborne potential of SARS-COV-2 and reported this virus had not airborne potential [13]. Although previous research conducted using laboratory nebulizer was reported that SARS-COV-2 had aerosol transmission potential and its airborne potential is plausible [14], but this field research confirms that SARS-Cov-2 had not airborne potential. We claim that the natural mechanism of patients’ cough and sneezing are differing than experimental nebulizers which considered in previous research for the airborne potential of viruses. Harvard medical school researchers reported that clear evidence of person-to-person airborne transmission of SARS-Cov-2 has not been reported. These researchers reported that the airborne component of transmission for SARS-Cov-2 is likely based on other respiratory viruses such as SARS, MERS, and influenza and air sampling for SARS-Cov-2, in a clinical setting, has demonstrated detectable viral RNA, the extent of transmission resulting from airborne particles relative to large respiratory droplets, directly and on surfaces, is not yet known [15].
Table 1

Presence of SARS-Cov-2 in indoor air samples

Samp. No.Sample pointsPump TypeTime(min)SampleVol. (L)Result
1Ward B4: Ward entranceP120100Neg.
2Ward B4: Post CCUP120100Neg.
3Ward B4: CorridorP120100Neg.
4Ward B4: Patients roomP120100Neg.
5Ward B4: Patient roomsP120100Neg.
6ICU 3: Ward entranceP120100Neg.
7ICU 3: Nursing StationP120100Neg.
8ICU 3: Isolation room 1P120100Neg.
9ICU 3: Isolation room 2P120100Neg.
10ICU 3: Isolation room 3P120100Neg.
11ICU 3: Isolation room 4P120100Neg.
12ICU 2: Ward areaP220800Neg.
13ICU 2: Ward areaP2251000Neg.
1410 D: Corridor and Nursing StationP215600Neg.
1510 D: Corridor and patients’ roomsP215600Neg.
1610 D: Corridor and patients’ roomsP215600Neg.
1710 D: Corridor and patients’ roomsP215600Neg.
18Emergency 1: Part 1P215600Neg.
19Emergency 1: Part 2P215600Neg.
20Emergency 1: Women’s wardP215600Neg.
21Emergency 1: Women’s wardP215600Neg.
22Emergency 1: Men’s wardP215600Neg.
23Emergency 1: Men’s wardP215600Neg.
24Emergency 1: Entrance and Triage SectionP215600Neg.
25ICU 3: All AreaP215600Neg.
26CT Scan: Waiting hall and ReceptionP215600Neg.
27CT Scan: Imaging room, near to the deviceP215600Neg.
28Emergency 1 part 1P220600Neg.
29Emergency 1 part 1P215600Neg.
30Emergency 1 part 1P215600Neg.
31LaundryP215600Neg.
Table 2

Environmental status of occupied wards with COVID-19 approved patients

Samp. No.Sample pointsTem°C (%Relative humidity)Patient Number (occupation %)Windows statusVentilation* systemSpace area(m2)
1Ward B4: Ward entrance28(49)------Pos. pressure20
2Ward B4: Post CCU24(43)6(100)2 ClosedPos. pressure40
3Ward B4: Corridor22(42)-------Pos. pressure8
4Ward B4:Patients room25(42)4(100)1 closedPos. pressure20
5Ward B4: Patient rooms25(42)4(100)1 closedPos. pressure22
6ICU 3 : Ward entrance23(42)0----Pos. pressure8
7ICU 3 : Nursing Station23(44)5 Staff1 openPos. pressure14
8ICU 3 : Isolation room 125(47)1(100)1 closedPos. pressure12
9ICU 3 : Isolation room 225(47)1(100)1 closedPos. pressure12
10ICU 3 : Isolation room 325(47)1(100)1 closedPos. pressure12
11ICU 3 : Isolation room 425(47)1(100)1 closedPos. pressure12
12ICU 2 : Ward area25(47)12(100)4 closedPos. pressure220
13ICU 2 : Ward area25(47)12(100)4 closedPos. pressure220
1410 D: Corridor and Nursing Station23(42)5(100)1 closedPos. pressure26
1510 D: Corridor and patients’ rooms24(47)4(100)1 closedPos. pressure300
1610 D: Corridor and patients’ rooms24(47)4(100)1 closedPos. pressure300
1710 D: Corridor and patients’ rooms24(47)4(100)1 closedPos. pressure300
18Emergency 1: Part 123(42)10(80)----Pos. pressure350
19Emergency 1: Part 222(43)10(80)---Pos. pressure300
20Emergency 1: Women’s ward23(43)17(100)8 closedPos. pressure300
21Emergency 1: Women’s ward23(43)17(100)8 closedPos. pressure300
22Emergency 1: Men’s ward23(43)5(45)8 closedPos. pressure290
23Emergency 1: Men’s ward23(43)5(45)8 closedPos. pressure290
24Emergency 1: Entrance and Triage Section23(43)7(100)------Pos. pressure40
25ICU 3 : All Area25(44)12(100)4 closedPos. pressure220
26CT Scan : Waiting hall and Reception24(42)4(30)2 closedPos. pressure90
27CT Scan: Imaging room, near to the device21(47)1(100)1 closedPos. pressure40
28Emergency 2: part 123(44)6(54)----Pos. pressure70
29Emergency 2: part 123(44)6(54)----Pos. pressure70
30Emergency 2: part 123(44)6(54)-----Pos. pressure70
31Laundry22(52)22 staff-------Pos. pressure310

*Mechanical ventilation supplied as central and positive pressure

Presence of SARS-Cov-2 in indoor air samples Environmental status of occupied wards with COVID-19 approved patients *Mechanical ventilation supplied as central and positive pressure CDC was reported that natural and mechanical ventilation is effective methods for SARS-Cov-2 control. This claim concurred with the findings of the present research in which the selected wards of the hospital had a mechanical air conditioning system and negative detectable viral RNA for SARS-Cov-2 in air samples. So, it can be concluded that the natural and mechanical air conditioning system with positive pressure is an available technology for air cleaning in patients’ convents and hospitals. Also, based on Klompas et al., reports no perfect experimental data are proving or disproving droplet vs. aerosol-based transmission of SARS-CoV-2 [16]. Finally, the balanced evidence, disproving aerosol-based transmission of SARS-CoV-2 particularly in well-ventilated spaces and suggests that long-range aerosol-based transmission is not the dominant mechanism of SARS-CoV-2 transmission. All of these relevant research concurs with the results of the present study.

Conclusions

In this comprehensive research 31 samples were analyzed for the occurrence of SARS-Cov-2 as the causative agent of COVID-19 in the indoor air of a referral hospital for admitting COVID-19 patients. Although the investigated hospital had the central and positive mechanical air condition system, this research revealed that SARS-Cov-2 had not airborne potential. Mechanical air conditioning and natural ventilation are available technologies that can be used for air cleaning in patients’ convents and hospitals. Despite these results, since medical staff have close contact with patients and work in a hazardous area, the protection of medical staff should not be violated and must be considered based on national and international strict guidelines.
  9 in total

1.  Investigation of SARS-CoV-2 in hospital indoor air of COVID-19 patients' ward with impinger method.

Authors:  Mehdi Vosoughi; Chiman Karami; Abdollah Dargahi; Farhad Jeddi; Kamyar Mazloum Jalali; Aidin Hadisi; Somayeh Biparva Haghighi; Hadi Peeri Dogahe; Zahra Noorimotlagh; Seyyed Abbas Mirzaee
Journal:  Environ Sci Pollut Res Int       Date:  2021-05-06       Impact factor: 4.223

2.  Letter to the editor "Investigation of SARS-CoV-2 in hospital indoor air of COVID-19 patients' ward with impinger method".

Authors:  Fazel Mohammadi-Moghadam; Sara Hemati
Journal:  Environ Sci Pollut Res Int       Date:  2021-09-13       Impact factor: 4.223

3.  SARS-CoV-2 detection in bioaerosols using a liquid impinger collector and ddPCR.

Authors:  Joan Truyols Vives; Josep Muncunill; Núria Toledo Pons; Herme G Baldoví; Ernest Sala Llinàs; Josep Mercader Barceló
Journal:  Indoor Air       Date:  2022-02       Impact factor: 6.554

4.  Reducing the Effectiveness of Ward Particulate Matter, Bacteria and Influenza Virus by Combining Two Complementary Air Purifiers.

Authors:  Bingliang Zhou; Tiantian Liu; Siqi Yi; Yuanyuan Huang; Yubing Guo; Si Huang; Chengxing Zhou; Rong Zhou; Hong Cao
Journal:  Int J Environ Res Public Health       Date:  2022-08-22       Impact factor: 4.614

5.  SARS-CoV-2 detection in hospital indoor environments, NW Iran.

Authors:  Amir Mohammadi; Ali Soleimani; Ali Abdolahnejad; Morshad Ahmed; Tanzina Akther; Sepideh Nemati-Mansour; Saber Raeghi; Gholam Hossein Rashedi; Mohammad Miri
Journal:  Atmos Pollut Res       Date:  2022-07-21       Impact factor: 4.831

6.  Investigation of SARS-CoV-2 Genome in the Indoor Air and High-Touch Surfaces.

Authors:  Iman Hadavi; Majid Hashemi; Gholamreza Asadikaram; Davood Kalantar-Neyestanaki; Ali Hosseininasab; Tooba Darijani; Maryam Faraji
Journal:  Int J Environ Res       Date:  2022-10-14       Impact factor: 3.229

Review 7.  SARS-CoV-2 air sampling: A systematic review on the methodologies for detection and infectivity.

Authors:  Priscilla G Silva; Pedro T B S Branco; Ruben R G Soares; João R Mesquita; Sofia I V Sousa
Journal:  Indoor Air       Date:  2022-08       Impact factor: 6.554

8.  On the airborne transmission of SARS-CoV-2 and relationship with indoor conditions at a hospital.

Authors:  Zeynab Baboli; Niloofar Neisi; Ali Akbar Babaei; Mehdi Ahmadi; Armin Sorooshian; Yaser Tahmasebi Birgani; Gholamreza Goudarzi
Journal:  Atmos Environ (1994)       Date:  2021-06-21       Impact factor: 4.798

9.  The detection of SARS-CoV-2 RNA in indoor air of dental clinics during the COVID-19 pandemic.

Authors:  Shahriyar Bazzazpour; Masoumeh Rahmatinia; Seyed Reza Mohebbi; Mostafa Hadei; Abbas Shahsavani; Philip K Hopke; Behzad Houshmand; Alireza Raeisi; Ahmad Jonidi Jafari; Maryam Yarahmadi; Mohsen Farhadi; Vajihe Hasanzadeh; Majid Kermani; Mohmmad Hossien Vaziri; Mohammad Tanhaei; Mohammad Reza Zali; Mohammad Reza Alipour
Journal:  Environ Sci Pollut Res Int       Date:  2021-08-03       Impact factor: 4.223