Tim Torsy1,2, Renée Saman3, Kurt Boeykens3, Mats Eriksson4, Sofie Verhaeghe5, Dimitri Beeckman5,4,6,7,8. 1. Department of Nursing, Odisee University College, Hospitaalstraat 23, 9100, Sint-Niklaas, Belgium. tim.torsy@odisee.be. 2. University Centre for Nursing and Midwifery, Ghent University, Ghent, Belgium. tim.torsy@odisee.be. 3. AZ Nikolaas General Hospital, Sint-Niklaas, Belgium. 4. School of Health Sciences, Örebro University, Örebro, Sweden. 5. University Centre for Nursing and Midwifery, Ghent University, Ghent, Belgium. 6. School of Nursing & Midwifery, Royal College of Surgeons in Ireland (RCSI), Dublin, Ireland. 7. Research Unit of Plastic Surgery, Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark. 8. School of Nursing and Midwifery, Monash University, Melbourne, Australia.
Abstract
OBJECTIVES: Chest X-ray imaging is frequently used for verifying the position of a blindly inserted nasogastric tube. A high-quality X-ray increases the likelihood of conclusive visibility of tube tip positioning, thus avoiding risks due to a misplaced tube (e.g., pulmonary intubation, pneumothorax, small bowel insertion). Therefore, this study aims to determine patient-related and environmental factors affecting the visibility of nasogastric tubes on X-ray in adults. METHODS: A retrospective descriptive analysis of routinely collected clinical data was performed on all included patients (N = 215) from a prospective randomized trial in a general hospital. A chest X-ray was taken of each patient needing a nasogastric feeding tube, after which visibility and positioning of the tube on X-ray was independently evaluated by 3 radiologists. RESULTS: In 14.9% (n = 32) of all patients, image quality was insufficient, so no conclusive visibility of nasogastric tube positioning could be found. A patient-related predictor regression model (sex, age, body mass index) explained 21% of variance for an insufficient visibility of the nasogastric tube (Nagelkerke R2 = 0.21). An environmental factor regression model demonstrates a guidewire being inside the tube or not during X-ray as a predictor for a conclusive visibility on X-ray. CONCLUSIONS: High body mass index, male sex, and the absence of a guidewire inside the nasogastric tube at the time of chest X-ray are associated with a risk of insufficient visibility of the tube on X-ray. Patient profiles can be defined in which supplementary attention is needed when obtaining chest X-rays whose purpose is to confirm nasogastric tube positioning. KEY POINTS: • The quality of chest X-rays to confirm the positioning of nasogastric tubes in adults can be improved considerably. • There are several factors influencing the confirmation of nasogastric tube positioning on X-ray. • Defining patient profiles at risk for an insufficient visibility of the tube on X-ray will indirectly contribute to an improvement of the chest X-ray quality.
OBJECTIVES: Chest X-ray imaging is frequently used for verifying the position of a blindly inserted nasogastric tube. A high-quality X-ray increases the likelihood of conclusive visibility of tube tip positioning, thus avoiding risks due to a misplaced tube (e.g., pulmonary intubation, pneumothorax, small bowel insertion). Therefore, this study aims to determine patient-related and environmental factors affecting the visibility of nasogastric tubes on X-ray in adults. METHODS: A retrospective descriptive analysis of routinely collected clinical data was performed on all included patients (N = 215) from a prospective randomized trial in a general hospital. A chest X-ray was taken of each patient needing a nasogastric feeding tube, after which visibility and positioning of the tube on X-ray was independently evaluated by 3 radiologists. RESULTS: In 14.9% (n = 32) of all patients, image quality was insufficient, so no conclusive visibility of nasogastric tube positioning could be found. A patient-related predictor regression model (sex, age, body mass index) explained 21% of variance for an insufficient visibility of the nasogastric tube (Nagelkerke R2 = 0.21). An environmental factor regression model demonstrates a guidewire being inside the tube or not during X-ray as a predictor for a conclusive visibility on X-ray. CONCLUSIONS: High body mass index, male sex, and the absence of a guidewire inside the nasogastric tube at the time of chest X-ray are associated with a risk of insufficient visibility of the tube on X-ray. Patient profiles can be defined in which supplementary attention is needed when obtaining chest X-rays whose purpose is to confirm nasogastric tube positioning. KEY POINTS: • The quality of chest X-rays to confirm the positioning of nasogastric tubes in adults can be improved considerably. • There are several factors influencing the confirmation of nasogastric tube positioning on X-ray. • Defining patient profiles at risk for an insufficient visibility of the tube on X-ray will indirectly contribute to an improvement of the chest X-ray quality.